1580 Commerce St, Corona, CA 92880
Contractor: Don Luginbill Roofing Inc
Date: Oct 23, 2013
Permit type: Residential
Description: 17,700 sf reroof * installation of roof coating * crrc # 0646-0012 * env-2c attached
Client: Verity Robert Roger
Permit #: B1302343
827 Filbert St, Corona, CA 92879
Contractor: Robert H Trapenberg
Date: Oct 24, 2013
Permit type: Residential
Description: Demo exisitng patio cover * demo existing shed * 900 sf reroof * remove/replace comp shingles (class a) * cf-1r-alt attached * re-stucco house * remove/replace water heater (same location) * misc electrical for gfi * copper repipe * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Lourdes Martinez
Permit #: B1302359
2039 Woodlawn Dr, Corona, CA 92882
Contractor: Robert H Trapenberg
Date: Oct 24, 2013
Permit type: Residential
Description: Roof mounted photovoltaic system* 8.25 kw*smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval * delta #1 submitted 10/28/13*12/19/13 delta #1 approved*1/2/14 delta #2 submitted to include service upgrade*remove 100 amp panel and install new 200 amp service same location*sce approval of the service location is required prior to installation. contact - tony lopez, edison planner at 909-930-8515*panel schedule attached, approved rw
Client: Peltzman Glen M
Permit #: B1302096
4143 Bennett Av, Corona, CA 92883
Contractor: T A K Electric Inc
Date: Oct 24, 2013
Permit type: Residential
Description: Photovoltaic system * 5.39 kw * (1) 100 amp sub panel * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Christiansen Jeffrey William
Permit #: B1301914
1621 Rivendel Dr, Corona, CA 92883
Contractor: Precis Development Inc
Date: Oct 28, 2013
Permit type: Residential
Description: Photovoltaic system * roof mounted *20 amp breaker*remove/replace water heater same location *smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval
Client: Romano Ivan
Permit #: B1300882
1404 Hearthside Dr, Corona, CA 92882
Contractor: Berry Roofing Inc
Date: Oct 30, 2013
Permit type: Residential
Description: 23 sq reroof * remove and reinstall existing tile * replace felt * * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Joel Strawser
Permit #: B1302384
1353 Vallejo Dr, Corona, CA 92882
Contractor: Solarmax Renewable Energy Provider Inc
Date: Oct 31, 2013
Permit type: Residential
Description: Roof mounted photovoltaic system* 4.6 kw* 200 amp main upgrade*service upgrade*remove 100 amp panel and install new 200 amp service same location*sce approval of the service location is required prior to installation. contact - tony lopez, edison planner at 909-930-8515*panel schedule attached*smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval
Client: Mcclain William J
Permit #: B1301787
830 Redriver Wy, Corona, CA 92882
Contractor: Ted Mount
Date: Nov 1, 2013
Permit type: Residential
Description: Roof mounted photovoltaic system* 7.15 kw* service upgrade*remove 100 amp panel and install new 200 amp service same location*sce approval of the service location is required prior to installation. contact - tony lopez, edison planner at 909-930-8515*panel schedule attached*smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval
Client: Swank Melinda Jean
Permit #: B1302048
1427 Granada Av, Corona, CA 92880
Contractor: Armstrong Roofing Limited
Date: Nov 5, 2013
Permit type: Residential
Description: 27 sq reroof * remove/replace comp shingles (class a) * cf-1r-alt attached * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Carson Willis
Permit #: B1302434
1947 Sage Av, Corona, CA 92882
Contractor: Mohr Power Solar Inc
Date: Nov 7, 2013
Permit type: Residential
Description: Photovoltaic system * 7.395 kw * (1) 125 microinverter sub panel * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Wiggins Herman P
Permit #: B1302337
3081 Arbor Glen Ct, Corona, CA 92879
Contractor: Future Energy Corp
Date: Nov 7, 2013
Permit type: Residential
Description: Photovoltaic system * roof mounted *3.91 kw*service upgrade*remove 100 amp panel and install new 200 amp service same location*smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval
Client: Trina G. Frantela
Permit #: B1302468
735 Allen Dr, Corona, CA 92879
Date: Nov 13, 2013
Permit type: Residential
Description: 50 amp sub panel
Client: Bennett Jeanette
Permit #: B1302507
898 Big Spring Ct, Corona, CA 92880
Contractor: Rec Solar Inc
Date: Nov 14, 2013
Permit type: Residential
Description: Photovoltaic system * roof mounted * 4.59 kw*(1) sub-panel @ 100 amp*smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection approval
Client: Bemis Wes K
Permit #: B1301307
1004 W Crestview St, Corona, CA 92882
Contractor: Tom German Electric, Inc.
Date: Nov 14, 2013
Permit type: Residential
Description: 200 amp main service upgrade (same location) * panel schedule attached * "sce approval of the service location is required prior to installation. contact - tony lopez, edison planner at 909/930-8515." **** "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: German Donald L
Permit #: B1302520
151 W Orange Heights Ln, Corona, CA 92882
Contractor: I A Construction Inc
Date: Nov 18, 2013
Permit type: Residential
Description: 384 sf detached tuff shed on perm foundation * foundation on permit # b1201195 *misc elec
Client: Merrill Lynch Bank Trust Co
Permit #: B1302123
3619 Summertree Ln, Corona, CA 92881
Contractor: I A Construction Inc
Date: Nov 20, 2013
Permit type: Residential
Description: Photovoltaic system * 7 kw * (1) 125 amp aub panel * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Alexander Wayne A
Permit #: B1302390
3360 Eagle Crest Dr, Corona, CA 92881
Contractor: J & L Electric
Date: Nov 21, 2013
Permit type: Residential
Description: 200 amp main service upgrade (same location) * panel schedule attached * "sce approval of the service location is required prior to installation. contact - tony lopez, edison planner at 909/930-8515." ** "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Amber Chambers
Permit #: B1302584
2736 Toumey Ln, Corona, CA 92881
Contractor: Innovative Electric Services Inc
Date: Nov 25, 2013
Permit type: Residential
Description: Photovoltaic system * 9 kw *service upgrade*remove 100 amp panel and install new 200 amp service same location* "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection"*delta 5 revised to show fence relocation ok per greg r over the counter*12/20/13*amp * delta #2 approved to sheet pv02, ok per greg
Client: Catalano Marco
Permit #: B1302314
320 Mount Vernon Wy, Corona, CA 92881
Contractor: American Solar Direct Inc
Date: Nov 25, 2013
Permit type: Residential
Description: Photovoltaic system * 8.25 kw * 100 amp sub panel * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Mas Luis P
Permit #: B1302307
2118 Mammoth Ln, Corona, CA 92879
Contractor: J T I Construction
Date: Nov 25, 2013
Permit type: Residential
Description: 2,500 sq reroof * remove/replace existing tile * install foam insulation * "smoke alarms and carbon monoxide alarms must be installed per the 2010 california residential code and verified prior to final inspection".
Client: Campbell Melvin D
Permit #: B1302608