4457 Main St, Philadelphia, PA 19127
Date: Nov 10, 2011
Permit type: Remodeling
Description: Interior demo of third floor, non load bearing partitions only for office.
Permit #: 371458
1201 Easton Rd, Philadelphia, PA 19150
Contractor: Enrico Roman Inc.
Date: Nov 14, 2011
Permit type: Remodeling
Description: Interior alteration includes new roof over existing building. see a/p 354625 for plans.
Permit #: 373297
1224 Panama St, Philadelphia, PA 19107
Contractor: Emerald Windows Inc
Date: Nov 14, 2011
Permit type: Remodeling
Description: All wood sash replacments in existing wood frames as per attached drawings and historical commission approval for apartment.
Permit #: 370381
1201 Easton Rd, Philadelphia, PA 19150
Contractor: Enrico Roman Inc.
Date: Nov 14, 2011
Permit type: Remodeling
Description: Creating (2) additions to a crematory. smaller addition being used for incinerator unit and larger unit for the addition of a walk-in cooler, processing room and receiving. interior alteration to existing new roof is being added over existing.
Permit #: 354625
337 Fitzgerald St, Philadelphia, PA 19148
Date: Nov 15, 2011
Permit type: Remodeling
Description: Interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties. licensed contractor to be listed on permit separate permits required for plumging, electric and hvac.
Permit #: 351848
323 Roselyn St, Philadelphia, PA 19120
Date: Nov 15, 2011
Permit type: Remodeling
Description: Family daycare for maximum six (6) children for periods of less than 24 consecutive hours with accessory preparing and serving of food incidental to and part of a single family dwelling in an existing structure. no sign on this permit.
Permit #: 373982
2829 Neptune Rd, Philadelphia, PA 19154
Date: Nov 15, 2011
Permit type: Remodeling
Description: Amend permit #362871. to include siding for exterior of the house.
Permit #: 368175
2209 Ruffner St, Philadelphia, PA 19140
Contractor: Mckeown Home Improvements, Inc.
Date: Nov 16, 2011
Permit type: Remodeling
Description: Re-build existing rear wall of single family dwelling per submitted plans.
Permit #: 371546
4530 Marple St, Philadelphia, PA 19136
Date: Nov 16, 2011
Permit type: Remodeling
Description: Interior alterations to include removal & replacing drywall, framing & insulation. applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated january 2011. deviation from the standard will result in revocation of this permit and imposition of further penalties.
Permit #: 374271
839 Emerson St, Philadelphia, PA 19111
Contractor: Design Details Unlimited
Date: Nov 16, 2011
Permit type: Remodeling
Description: For the erection of a three(3) story detached structure ( nte 35') with cellar and with interior garage on first floor.size and location as shown n the application.
Permit #: 373054
2401 Benson St, Philadelphia, PA 19152
Contractor: Tri-County Contracting Corp
Date: Nov 17, 2011
Permit type: Remodeling
Description: For the removal and replacement in kind of six (6) balconies (with guardrails 42" high, balconies at 1st, 2nd and 3rd floor levels). size and location as shown in the application.
Permit #: 373457
2400 Benson St, Philadelphia, PA 19152
Contractor: Tri-County Contracting Corp
Date: Nov 17, 2011
Permit type: Remodeling
Description: For the removal and replacement in kind of twelve (12) balconies (with guardrails 42" high, balconies at 1st, 2nd and 3rd floor levels). size and location as shown in the application.
Permit #: 372700
13500 Philmont Ave, Philadelphia, PA 19116
Date: Nov 17, 2011
Permit type: Remodeling
Description: For a day care center with accessory preparing and serving of food for period of less than 24 consecutive hours church operated and church affiliated for children of church employees on the same lot with an existing church and school with all other uses as previously approved in an existing structure. no sign on this permit.
Permit #: 374577
4122 Dungan St, Philadelphia, PA 19124
Contractor: J And J Construction And Remodeling Llc
Date: Nov 17, 2011
Permit type: Remodeling
Description: Installation of fire rated entry door to a two family dwelling. install 5/8 drywall where needed for fire rated walls between units.
Permit #: 374474
814 Scotia Rd, Philadelphia, PA 19128
Contractor: Michael J Kenny
Date: Nov 17, 2011
Permit type: Remodeling
Description: Interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties. licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac
Permit #: 374375
2839 Angus Rd, Philadelphia, PA 19114
Date: Nov 17, 2011
Permit type: Remodeling
Description: Remove front garage door, infill with wood frame and patio doors. house built 1960
Permit #: 374016
2141 66Th Ave, Philadelphia, PA 19138
Date: Nov 18, 2011
Permit type: Remodeling
Description: Interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties. licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac
Permit #: 374638
3239 Tampa St, Philadelphia, PA 19134
Date: Nov 18, 2011
Permit type: Remodeling
Description: Sheetrock interior walls and ceilings, replace 6 windows same size/opening. stucco front wall. ** wall requires inspection before starting work. interior alterations - single family dwelling - applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties. licensed contractor to be listed on permit separate permits required for plumbing, electric and hvac. call inspector at district office at least 24 hours prior to starting work. stucco - exterior plaster. installation of these materials shall be in compliance withastmc926 andastmc1063 and the provisions of this code. r703.6.1 lath. all lath and lath attachments shall be of corrosion- resistant materials. expanded metal or woven wire lath shall be attached with 1-1/2-inch-long (38 mm), 11 gage nails having a 7/16-inch (11.1 mm) head, or 7/8-inch-long (22.2 mm), 16 gage staples, spaced at no more than 6 inches (152 mm), or as otherwise approved.
Permit #: 374586
841 Montrose St, Philadelphia, PA 19147
Contractor: Chang Construction Group Inc
Date: Nov 18, 2011
Permit type: Remodeling
Description: "applicant agrees to limit the construction to comply with ez permit standard for interior alterations, dated february, 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties."separate permits required for plumbing, electrical and mechanical work
Permit #: 374297
7429 Brockton Rd, Philadelphia, PA 19151
Date: Nov 18, 2011
Permit type: Remodeling
Description: For a three (3) family dwelling in an existing structure (size and location as shown in the application).
Permit #: 374504