Contractors DirectoryInformation on every contractor in United States

Remodeling Permits in Louisville, KY

923 Livingston Ave, Louisville, KY 40215

Date: Mar 1, 2010

Permit type: Remodeling

Description: 338 sf of second floor addition on first floor existing walls and existing foundation. includes new second floor stairway plus three piers and girders in crawlspace to support stair wall. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including: rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; wall bracing r602.10; smoke alarms r313; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values and u-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector. approved plans per irc section r106.3.1. mi

Valuation: $800,000

Client: Andrew E Winfield

Permit #: 259053

302 Renn Ct, Louisville, KY 40245

Date: Mar 1, 2010

Permit type: Remodeling

Description: 430 sf of interior basement renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r317; combustion air, ventilation and dilution air g2407.5.1; louvers and grilles g2407.10; and combustion air from inside of building with confined space m1702.2. separate permit required for electric. bedrooms not allowed in basement without emergency egress per sec r310. - hh

Valuation: $600,000

Client: Alicon & Philip Bradshaw

Permit #: 259093

7008 Brook Bend Way, Louisville, KY 40229

Date: Mar 1, 2010

Permit type: Remodeling

Description: Sf of interior basement renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r317; combustion air, ventilation and dilution air g2407.5.1; louvers and grilles g2407.10; and combustion air from inside of building with confined space m1702.2. separate permit required for electric. bedrooms not allowed in basement without emergency egress per sec r310. - hh

Valuation: $1,500,000

Client: Steven W & Cynthia A Marlow

Permit #: 259070

3233 Richard Ave, Louisville, KY 40206

Date: Mar 1, 2010

Permit type: Remodeling

Description: 855 sf of interior basement renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r317; combustion air, ventilation and dilution air g2407.5.1; louvers and grilles g2407.10; and combustion air from inside of building with confined space m1702.2. separate permit required for electric. bedrooms not allowed in basement without emergency egress per sec r310. - hh

Valuation: $450,000

Client: Kenneth Edward Hayden

Permit #: 259084

4406 Ole Brickyard Cir, Watterson Park, KY 40218

Date: Mar 1, 2010

Permit type: Remodeling

Description: Office renovation for "john conti". all constr. shall comply w/2007 ky. bldg. code. any change to existing sprinklers shall be done in accordance with nfpa 13. no work in existing warehouse & as noted on plan, no fire separation req'd between "b" & "s-1" uses. all walls existing but new drywall added. new restrooms must be hc accessible. providing 1 hr. fire rating around existing electrical room. maintain exit signs & emergency lighting. as per architect, occupant load is 65 persons in this office area. aw

Valuation: $6,000,000

Client: Conti Realty Llc John

Permit #: 258647

2005 High Canyon Rd, Riverwood, KY 40207

Contractor: Ies Residential

Date: Mar 1, 2010

Permit type: Remodeling

Description: Remodel

Valuation: $200,000

Client: Christopher Coleman & Park

Permit #: 259111

5816 Shepherd Crossing Dr, Louisville, KY 40219

Contractor: Jrs Construction Services

Date: Mar 2, 2010

Permit type: Remodeling

Description: Updated to include 1,300sqft finished basement and reinstate permit for additional 6 months janice** shephards crossing building g unit #40- br vnr one story (1,309sqft) unfin/bsmt. (288sqft) att. garage; (96sqft) deck. shall comply with 2007 kbc including fire partitions 708 and ansi a117.1 2003. approved per zoning docket # 12736 shall not encroach any easements or required yards. agency approvals in permit # 148594. separate permit required when finishing bsmt. jmj

Valuation: $7,140,000

Client: Steven R & Barbara A Ross

Permit #: 246605

4303 Poplar Level Rd, Watterson Park, KY 40213

Contractor: Cummings Inc

Date: Mar 2, 2010

Permit type: Remodeling

Description: Installing new led sign on front facade. as per sec. 8.1.6.m of the ldc, all image change shall not exceed a rate of change of once per 20 seconds. no other signs this facade. aw

Valuation: $600,000

Client: Investments Ltd Schoening

Permit #: 258954

238 Saunders Ave, Louisville, KY 40206

Contractor: Ben Tyler Building And Remodeling Inc

Date: Mar 2, 2010

Permit type: Remodeling

Description: Interior renovation only walls framed in existing walkout bmst for office & closet. work is not outside of existing footprint.any exterior work including doors, windows & paint require landmarks approval. has sewer tap receipt under permit #138469. shall comply with 2007 krc: smoke alarms r313; separate permit required to fin remainder of bsmt:bedrooms not allowed in bmst without emergency egress r310; energy conservation r1102; single family residence only: no multifamily use. property is on sewers and not in flood prone area. dmt

Valuation: $550,000

Client: Andrew J & Clark Jessi Dettmer

Permit #: 259189

2205 Speed Ave, Louisville, KY 40205

Contractor: Oerther Dan Complete Home Impr

Date: Mar 2, 2010

Permit type: Remodeling

Description: Renovation of three existing rest rooms in a single family dwelling.one rest room to have door to toilet room relocated, with original opening studded and dry walled.two rest rooms to be gutted and dry walled with ceramic tile installed. all work to meet the requirments of the krc.

Valuation: $2,500,000

Client: Daniel C Jr & Robin D Scullin

Permit #: 259231

7200 Global Dr, Louisville, KY 40258

Contractor: Simplex Grinnell Lp

Date: Mar 2, 2010

Permit type: Remodeling

Description: Add 42 heads in new space "southern states". no bldg permit required. shall comply with npfa 13. jmj

Valuation: $1,000,000

Client: Louisville Llc Ktr

Permit #: 258875

4304 Tulip Grove Ct, Louisville, KY 40241

Date: Mar 3, 2010

Permit type: Remodeling

Description: 240 sf covered screened deck, plus 240 sf uncovered deck. shall comply to 2007 krc including, stairs r311.5; handrails r311.5.6; guards r312; floor joist span r502.3; girder span r502.5; decks 502.2.2.2; quality mark required information r319.2.1; field treatment r319.1.1. shall not encroach any easements or required yards. shall deliver lvl beam load calcs to field inspector. separate permit required for electric. approved plans per irc section r106.3.1. mi

Valuation: $2,550,000

Client: Courtney & Michael Drake

Permit #: 259268

11811 Standiford Plaza Dr, Louisville, KY 40229

Contractor: Crane Construction Company

Date: Mar 4, 2010

Permit type: Remodeling

Description: Remodel to the "kohl's department store" also installing new eifs system of the facade. shall comply

Valuation: $70,000,000

Client: Department Stores Inc Kohls

Permit #: 251091

4307 Mount Vernon Rd, St Regis Park, KY 40220

Date: Mar 5, 2010

Permit type: Remodeling

Description: 75sqft bathrm remodel on 1st floor; work to include drywall, replacing tub and vanity; comestics;putting in a vent. not changing the footprint of house. verbal approval from st regis park (not required interior work only). shall comply with 2007 krc. emergency egress r310; smoke alarms r313; glazing r308; exterior wall location r302; handrails r311.5.6; guards r312; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u values in zone 4 and shall be posted on or in the electrical distribution panel. shall provide written manufacturer per r613.1 to be delivered the field inspector. no commercial use allowed. single family dwelling only. conditional use permit (c.u.p) required for multi family. all bedrooms to meet emergency egress. property is located on sewers and not in flood prone area per the dpi. jmj

Valuation: $500,000

Client: Ryan M & Victoria L Leonhart

Permit #: 259504

4615 Taylor Blvd, Louisville, KY 40215

Contractor: Corbett Construction Company, Inc.

Date: Mar 8, 2010

Permit type: Remodeling

Description: Renovation of existing school.renovation to consist of complete replacement of hvac system,electrical switch gear upgrade including new 28'x 12'electric room addition to rear of primary structure, fire alarm upgrade,security system upgrade, floor tile replacement, partial ceiling and light fixture replacement,partial roof replacement, window replacement and fire protection system modification.additional permits required for fire detection and suppression. community facility review approval for addition in file. all work to meet the requirements of the 2007 kbc. mam

Valuation: $124,000,000

Client: Jefferson County School District

Permit #: 256002

13010 Shamus Ct, Louisville, KY 40299

Date: Mar 8, 2010

Permit type: Remodeling

Description: Basement finish. rooms to include theater rm, bar area; sitting rm, workout rm & bath rm; closet & storage. sf of interior bsmt. renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r313. ceiling height r305. seperate permit required for electric. bedrooms not allowed in bsmt without emer. egress per sec r310. single family dwelling only. conditional use permit (c.u.p) required for multi family. no commercia luse allowed. . a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u vaules in zone 4. shall be posted on or in the electrical distribution panel. shall provide written manfacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. single family dwelling. conditional use permit required for multi family. jmj

Valuation: $3,000,000

Client: Shawn & Rebecca Mcdonald

Permit #: 259619

14104 Spring Mill Rd, Louisville, KY 40245

Contractor: Ies Residential

Date: Mar 9, 2010

Permit type: Remodeling

Description: Remodel

Valuation: $200,000

Client: Robert L & Buelah E Powell

Permit #: 259780

5504 Speedway Ave, Louisville, KY 40272

Contractor: Karrer Construction Co Inc

Date: Mar 9, 2010

Permit type: Remodeling

Description: 804 sf renovation of existing frame single family dwelling on crawl ( to replace drywall, insulation and change floor plan ) 627 sf one story frame addition on crawl .w/ att 144 sf uncovered rear deck. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; girder span r502.5; decks 502.2.2.2; protection against decay r319 smoke alarms r313; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector .-cc

Valuation: $3,400,000

Client: Construction Co Llc Karrer

Permit #: 259789

8706 Gainsborough Dr, Louisville, KY 40291

Contractor: Probuilt Renovation And Design, Llc

Date: Mar 10, 2010

Permit type: Remodeling

Description: Renovation non load bearing walls removed & reframed for handicap accessiblity: baths & hallways enlarged, frame for closet & laundry; cosmetic: replace doors & fixtures. work is not outside of existing footprint. shall comply with 2007 krc. property is on sewers and not in flood prone area. dmt

Valuation: $5,317,000

Client: Vi Wabash Properties L Sp

Permit #: 259836

15423 Beckley Hills Dr, Louisville, KY 40245

Date: Mar 10, 2010

Permit type: Remodeling

Description: 1700 sf of interior walk out bsmt. renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r313. seperate permit required for electric. bedrooms not allowed in bsmt without emer. egress per sec r310.-cc

Valuation: $500,000

Client: Darin A & Julie H Long

Permit #: 259873

All data is collected from public records. We do not guarantee accuracy of information.