Contractors DirectoryInformation on every contractor in United States

Remodeling Permits in Louisville, KY

3903 Atkinson Square Dr, Watterson Park, KY 40218

Contractor: Legrand Fire Protection Inc

Date: Dec 11, 2009

Permit type: Remodeling

Description: New sprinkler system for sullivan-college - hvac building-( 3903 atkinson square dr).shall comply to 2007 kbc and nfpa 13.***notice, this fire suppression permit is issued on condition that you obtain approval from the appropriate fire district for the location and type of the required fire department connection before installation.your permit location is in the camp taylor fire district. please contact them at 502-451-7757 to set up a review for approval before beginning the installation.*** does have msd connection .-cc

Valuation: $3,000,000

Client: Alva R Schrenk Patricia L Sullivan

Permit #: 253705

13407 Forest Springs Dr, Louisville, KY 40245

Contractor: C & S Custom Homes & Remodel

Date: Dec 11, 2009

Permit type: Remodeling

Description: Renovation 1246 sf of interior basement: frame for office, full bath, exercise, family & mechanical. work is not outside of existing footprint. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r317; combustion air, ventilation and dilution air g2407.5.1; louvers and grilles g2407.10; and combustion air from inside of building with confined space m1702.2; energy conservation r1102. property is on sewers and not in flood prone area. separate permit required for electric. bedrooms not allowed in basement without emergency egress per sec r310. - hh

Valuation: $2,400,000

Client: John M & Christy M Kuprion

Permit #: 253819

102 Bauer Ave, Saint Matthews, KY 40207

Date: Dec 11, 2009

Permit type: Remodeling

Description: Expansion of a existing bar. moving into the space in front of them which used to be retail. all wor

Valuation: $1,500,000

Client: Gerald L Ford

Permit #: 253747

4313 Wells Dr, Louisville, KY 40258

Contractor: R & I Construction

Date: Dec 14, 2009

Permit type: Remodeling

Description: 300 sf renovation, including 4 primary windows replacement and one exterior door replacement. rear shed roof to be re-raftered. permit modification required for any foundation work. shall comply to 2007 krc. seperate permit required for electric. has water mgt initaled approval. mi

Valuation: $200,000

Client: Rene Castillo

Permit #: 249811

7708 Aspen Ridge Rd, Louisville, KY 40214

Contractor: Clifford Thienemen Co Inc

Date: Dec 14, 2009

Permit type: Remodeling

Description: Basement finish for lot 53 oak hills sec 2. room to be game rm . shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r313. ceiling height r305. seperate permit required for electric. bedrooms not allowed in bsmt without emer. egress per sec r310. single family dwelling only. conditional use permit (c.u.p) required for multi family. no commercia luse allowed. . a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u vaules in zone 4. shall be posted on or in the electrical distribution panel. shall provide written manfacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. single family dwelling. conditional use permit required for multi family. jmj

Valuation: $1,000,000

Client: Ross Craig Kayser Lindsey Nico Kayser

Permit #: 253678

4800 Allmond Ave, Louisville, KY 40214

Contractor: Advanced Electrical System Inc

Date: Dec 14, 2009

Permit type: Remodeling

Description: Card, office renovation which includes replacing existing fixtures throughout & wall switches will need above ceiling & final inspections

Valuation: $16,000,000

Client: Steel Kentucky Inc Oneal

Permit #: 254006

732 Wicklow Rd, Windy Hills, KY 40207

Date: Dec 14, 2009

Permit type: Remodeling

Description: 272 sf one story room addition of wood frame construction with 387 sf renovation and 136sf treated wood deck. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r317. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors)-.40 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. - hh

Valuation: $7,500,000

Client: Tommy L & Helen M Davis

Permit #: 253407

300 Abraham Flexner Way, Louisville, KY 40202

Contractor: Klarer Construction Company, Inc.

Date: Dec 15, 2009

Permit type: Remodeling

Description: Renovation of existing pharmacy area to include modification to the existing mechanical,plumbing and electrical systems. this project has been approved through the state under case number 017199-000-t. all work to meet the requirements of the 2007 kbc. mam

Valuation: $10,500,000

Client: Of Kentucky For Univ.. Commonwealth

Permit #: 253694

1124 Clay Ave, Louisville, KY 40219

Date: Dec 15, 2009

Permit type: Remodeling

Description: 6x30 one story frame on crawl addition for full bath, closet & mud. no deck, vaults & retaining wall

Valuation: $1,200,000

Client: Corporation Rycom

Permit #: 254034

140 Fenley Ave, Louisville, KY 40206

Date: Dec 15, 2009

Permit type: Remodeling

Description: Updated 7-2-2010 to include 272sqft partial covered deck onto rear of house *** 290 sf one story frame addition on crawlspace. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; wall bracing r602.10; smoke alarms r313; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values and u-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector . mi

Valuation: $1,500,000

Client: Victor R & Nancy E Stoess

Permit #: 253956

1277 Farmdale Ave, Louisville, KY 40213

Date: Dec 15, 2009

Permit type: Remodeling

Description: Removal of single family dwelling. as per pva, this structure was built in 1920. approved for dmeo as per site visit by john o. on 4-3-08. approved for demo. as per richard jett on 4-14-08. permit expires 30 days from date issued. aw

Client: Pollie Hall

Permit #: 192184

1263 Bassett Ave, Louisville, KY 40204

Contractor: Pdp Contracting Llc

Date: Dec 15, 2009

Permit type: Remodeling

Description: 2400 sf existing two story dwelling interrior renovation (to remove drywall and replace insulation change opening and add stairs on first and second floors.)and 100 sf exterrior renovation for (replcement of windows and doors.)shall comply to 2007 krc including walls r602, wall covering r702; smoke alarms r313.a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector . seperate permit required for electric. bedrooms not allowed without emer. egress per sec r310. has cert. of appro. #13626.-cc

Valuation: $6,000,000

Client: Paul Sidebottom

Permit #: 253590

520 Old Stone Ln, Windy Hills, KY 40207

Contractor: Wilkinson Builders, Inc.

Date: Dec 16, 2009

Permit type: Remodeling

Description: Add/renovation to existing house onto side and new attached garage. shall comply with 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313; glazing r308; exterior wall location r302; stairs r311; handrails r311.5.6; guards r312; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u values in zone 4 and shall be posted on or in the electrical distribution panel. shall provide written manufacturer per r613.1 to be delivered the field inspector. no commercial use allowed. single family dwelling only. conditional use permit (c.u.p) required for multi family. all bedrooms to meet emergency egress. jmj

Valuation: $40,000,000

Client: H Clark Family Trust Suzanne

Permit #: 254166

512 Oxford Pl, Saint Matthews, KY 40207

Contractor: Svs Incorporated

Date: Dec 16, 2009

Permit type: Remodeling

Description: Check# 2287, wiring of 2nd floor bedroom bathroom

Valuation: $300,000

Client: Aaron B & Corbett Ma.. Higginbotham

Permit #: 254114

13600 Brooksong Ct, Louisville, KY 40245

Contractor: Stonelake Homes Llc

Date: Dec 16, 2009

Permit type: Remodeling

Description: 195 sf of interior bsmt. renovation. shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r313; energy efficiency chapter 11. separate electrical permit required for electric. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. bedrooms not allowed in bsmt. without emer. egress per sec r310. mi

Valuation: $2,000,000

Client: Mark & Barbara T Shirkness

Permit #: 254177

6912 Deep Spring Ct, Spring Mill, KY 40228

Date: Dec 16, 2009

Permit type: Remodeling

Description: 255 covered deck. shall comply to 2007 krc including, floor joist span r502.3; rafter span r802.5; girder span r502.5; decks 502.2.2.2; quality mark required information r319.2.1; field treatment r319.1.1. shall not encroach any easements or required yards. separate permit required for electric. mi

Valuation: $1,200,000

Client: Eric S & Susan S Wahl

Permit #: 254162

2604 River Green Cir, Louisville, KY 40206

Date: Dec 17, 2009

Permit type: Remodeling

Description: Change of use from office warehouse to a gymasium (competitive edge). all work to be in accordance with kbc 2007 edt. note; the occuapant load is 304 persons. must re-work the sprinklers in accordance with nfap 13 and a new fire alarm system must be installed in accordance with nfpa 72. all material to be of non-combustible material. the space to be handicap accessible in accordance with ch 11. panic hardware to be installed on required egress doors. must provide exit designation and emergency lighting. lm

Valuation: $1,650,000

Client: Livron

Permit #: 253574

241 Steedly Dr, Louisville, KY 40214

Contractor: Wehr Constructors, Inc.

Date: Dec 18, 2009

Permit type: Remodeling

Description: Addition & renovation for "kentucky humane society". shall comply with kbc 2007 including sec 705.3 fire wall. unsprinklered corridor shall be one hour fire rated. dishwasher shall required type 2 hood. the building to be handicap accessible in accordance with ch 11. maintain existing fire detection, add devices as required per nfpa 72. maintain existing egress and add exit signs as required. approved per luapp 12721. occupant load 156. jmj

Valuation: $100,000,000

Client: Humane Society Kentucky

Permit #: 242608

2208 Dearing Ct, Louisville, KY 40204

Date: Dec 21, 2009

Permit type: Remodeling

Description: Interior renovation only without landmarks approval. two story frame duplex 2nd floor unit gutted to studs; insulate 1st through ballon framing: 1hr fire separation to be maintained; stairs repaired; cosmetic to include drywall, flooring, fixtures, trim & paint. all walls existing:work is not outside of existing footprint. shall comply with 2007 krc: fire separation between dwelling units r317; energy conservation r1102. property is on sewers and not in flood prone area. separate permit required for electrical, hvac & plumbing. dmt

Valuation: $96,600

Client: Jay S Merriam

Permit #: 254489

4633 Dover Rd, Louisville, KY 40216

Date: Dec 21, 2009

Permit type: Remodeling

Description: 12 sf renovation on first floor for half bath. 1023 sf of interior bsmt. renovation for a family room / utility room . shall comply to 2007 krc, including walls r602, wall covering r702; smoke alarms r313. separate permit required for electric. bedrooms not allowed in bsmt without emer. egress per sec r310. -cc

Valuation: $2,000,000

Client: David Holyfield

Permit #: 254511

All data is collected from public records. We do not guarantee accuracy of information.