Contractors DirectoryInformation on every contractor in United States

New Construction Permits in Louisville, KY

5315 Galaxie Dr, Louisville, KY 40258

Contractor: Tawana Hughes Builders

Date: Nov 14, 2012

Permit type: New Construction

Description: 30x40 one story frame unconditioned detached garage. no retaining walls. shall comply with 2007 krc: foundation r403; engineered members including lvl beams & trusses, sealed documentation to be provided to inspector on site. no commercial use allowed. shall not encroach any easements or required yards. approvals are under permit #347268. dmt

Valuation: $700,000

Client: Joe & Peg Fey

Permit #: 347273

9806 Hofelich Ln, Louisville, KY 40291

Contractor: Steven B Cline Garages

Date: Nov 14, 2012

Permit type: New Construction

Description: 26x24 one story detached block garage attached to side of house by breezeway. shall not encroach front building limit line, easements or required yards. shall comply with krc 2007. no commercial use allowed. janicemjohnston

Valuation: $1,000,000

Client: Thomas Jr & Mary Knight

Permit #: 347263

5016 Carriage Pass Pl, Louisville, KY 40299

Contractor: Karem Built Homes Inc

Date: Nov 14, 2012

Permit type: New Construction

Description: Lot 66 saratoga springs one story br veneer unfin walkout bmst with 456' att garage & 160' deck. no vaults. homebuilder association retaining wall detail submitted for over 4' wall. shall comply with 2007 krc: foundation r403; headers/ledger r502; energy conservation r1102; engineer members including steel & lvl beams, sealed documentation to be provided to inspector on site; separate permit required to fin bmst, bedrms not allowed without emergency egress; single family residence only, no multifamily use without pds cup approval. shall not encroach any easments or required yards. dmt

Valuation: $22,000,000

Client: Built Homes Inc Karem

Permit #: 347212

4103 Bold Ruler Way, Louisville, KY 40214

Contractor: Scot-Bilt Homes

Date: Nov 15, 2012

Permit type: New Construction

Description: 25x25 one story detached frame garage located 25' from side of house, 35' from nearest side property line and 25'++ from rear of house. shall comply with krc 2007. no commercial use allowed. shall not encroach any easements or required yard. janicemjohnston

Valuation: $1,500,000

Client: James S & Tammi R Dawson

Permit #: 347387

8631 Oaks Way, Louisville, KY 40299

Contractor: Derby City Quality Homes Inc

Date: Nov 15, 2012

Permit type: New Construction

Description: Lot 38 village of bristol oaks ph i & ii new house frame two story finished 700sqft. 419sqft att. garage; 192sqft deck. is for single family residential use only. no other use is allowed pursuant to the structure shall comply with the krc 2007 and iecc 2009 codes. no commercial use allowed. the structure shall not go over any easements or required yards. it is the owner?s responsibility to abide by all subdivision rules in the completion of this project. note: carbon monoxide alarms, sec r325 shall be required for new construction. an approved carbon monoxide alarms shall be installed outside of each sleeping area in the immediate vicinity of all bedrooms in dwelling with which fuel-fired appliances are installed and in dwelling units that have attached garages. decks shall comply with 2007 krc. the ends of all lag screws thru a combined ledger board and band board, shall be visible to the field inspector. deck includes minimum 2? x 8? pressure treated ledger board or other approved engineered materials, all ledger flashing, and staggered lag screw/bolt patterns. if the hole is drilled through the masonry and the bolt is merely passing through the masonry and is in fact secured to the band board of the house, and connecting the ledger to the band board (or other structure within the house) and is not actually fastened to the masonry, but merely passing through without adding any vertical or lateral load, then no engineer is required. in this scenario there is no reason to remove the brick but the integrity of the brick veneer must be maintained. if the bolt is not merely passing through the masonry, but in fact depends upon the masonry for vertical or lateral support, then an engineer is required to document that the masonry can handle the added vertical or lateral load wood/plastic composite deck boards shall be installed in accordance with the manufacturers instructions. janicemjohnston

Valuation: $12,600,000

Client: S Stilger Company T

Permit #: 347346

6700 Woodrow Way, Louisville, KY 40228

Contractor: Riggs Electrical

Date: Nov 15, 2012

Permit type: New Construction

Description: New single family construction

Valuation: $500,000

Client: Leigh Custom Built Hom Chris

Permit #: 347329

6613 Fernbush Dr, Louisville, KY 40228

Contractor: Riggs Electrical

Date: Nov 16, 2012

Permit type: New Construction

Description: New construction single family

Valuation: $500,000

Client: Leigh Custom Built Hom Chris

Permit #: 347333

5516 Random Way, Louisville, KY 40291

Contractor: Bender Construction Company

Date: Nov 16, 2012

Permit type: New Construction

Description: 114 sf one story front porch addition of wood frame construction of single family dwelling. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 11/16/2012 for full build construction. - hh

Valuation: $700,000

Client: James & Shannon Gagliardi

Permit #: 347522

7609 Wind Haven Ct, Louisville, KY 40291

Date: Nov 16, 2012

Permit type: New Construction

Description: Lot 132 windgate meadows sec 6b new house br vnr one and half unfinished basement. 708sqft att. garage; 336sqft deck. is for single family residential use only. no other use is allowed pursuant to the structure shall comply with the krc 2007 and iecc 2009 codes. no commercial use allowed. the structure shall not go over any easements or required yards. it is the owner?s responsibility to abide by all subdivision rules in the completion of this project. note: carbon monoxide alarms, sec r325 shall be required for new construction. an approved carbon monoxide alarms shall be installed outside of each sleeping area in the immediate vicinity of all bedrooms in dwelling with which fuel-fired appliances are installed and in dwelling units that have attached garages. decks shall comply with 2007 krc. the ends of all lag screws thru a combined ledger board and band board, shall be visible to the field inspector. deck includes minimum 2? x 8? pressure treated ledger board or other approved engineered materials, all ledger flashing, and staggered lag screw/bolt patterns. if the hole is drilled through the masonry and the bolt is merely passing through the masonry and is in fact secured to the band board of the house, and connecting the ledger to the band board (or other structure within the house) and is not actually fastened to the masonry, but merely passing through without adding any vertical or lateral load, then no engineer is required. in this scenario there is no reason to remove the brick but the integrity of the brick veneer must be maintained. if the bolt is not merely passing through the masonry, but in fact depends upon the masonry for vertical or lateral support, then an engineer is required to document that the masonry can handle the added vertical or lateral load wood/plastic composite deck boards shall be installed in accordance with the manufacturers instructions. janicemjohnston

Valuation: $25,000,000

Client: Meadows Windgate

Permit #: 347483

1900 Lonesome Hollow Rd, Louisville, KY 40272

Contractor: Ken Thieneman Builder, Inc.

Date: Nov 16, 2012

Permit type: New Construction

Description: Foundation only (not in recorded subd) two story with 828sqft garage in bsmt. 790sqft covered porch. is for single family residential use only. no other use is allowed pursuant to the structure shall comply with the krc 2007 and iecc 2009 codes. no commercial use allowed. the structure shall not go over any easements or required yards. it is the owner?s responsibility to abide by all subdivision rules in the completion of this project. note: carbon monoxide alarms, sec r325 shall be required for new construction. an approved carbon monoxide alarms shall be installed outside of each sleeping area in the immediate vicinity of all bedrooms in dwelling with which fuel-fired appliances are installed and in dwelling units that have attached garages. decks shall comply with 2007 krc. the ends of all lag screws thru a combined ledger board and band board, shall be visible to the field inspector. deck includes minimum 2? x 8? pressure treated ledger board or other approved engineered materials, all ledger flashing, and staggered lag screw/bolt patterns. if the hole is drilled through the masonry and the bolt is merely passing through the masonry and is in fact secured to the band board of the house, and connecting the ledger to the band board (or other structure within the house) and is not actually fastened to the masonry, but merely passing through without adding any vertical or lateral load, then no engineer is required. in this scenario there is no reason to remove the brick but the integrity of the brick veneer must be maintained. if the bolt is not merely passing through the masonry, but in fact depends upon the masonry for vertical or lateral support, then an engineer is required to document that the masonry can handle the added vertical or lateral load wood/plastic composite deck boards shall be installed in accordance with the manufacturers instructions. per ken thieneman: there will not be a retaining wall over 4' tall. from: [email protected] to: [email protected] subject: re: 1900 lonesome hollow date: thu, 15 nov 2012 12:09:42 +0000 ok. the retaining wall, are you going to have one? and if so: janicemjohnston

Valuation: $1,000,000

Client: Steven R Jahn

Permit #: 347400

7806 Wood Duck Way, Louisville, KY 40218

Contractor: Romanoff Electric Louisville

Date: Nov 19, 2012

Permit type: New Construction

Description: New construction permit; 170 bannon crossing

Valuation: $150,000

Client: Homes Of Ky Ltd Dominion

Permit #: 347611

515 Standwick Way, Louisville, KY 40245

Contractor: Ball Homes, Llc

Date: Nov 20, 2012

Permit type: New Construction

Description: Lot 125 notting hill sec 2 foundation only br vnr one story basement. 462sqft att. garage;86sqft deck. is for single family residential use only. no other use is allowed pursuant to the structure shall comply with the krc 2007 and iecc 2009 codes. no commercial use allowed. the structure shall not go over any easements or required yards. it is the owner?s responsibility to abide by all subdivision rules in the completion of this project. note: carbon monoxide alarms, sec r325 shall be required for new construction. an approved carbon monoxide alarms shall be installed outside of each sleeping area in the immediate vicinity of all bedrooms in dwelling with which fuel-fired appliances are installed and in dwelling units that have attached garages. decks shall comply with 2007 krc. the ends of all lag screws thru a combined ledger board and band board, shall be visible to the field inspector. deck includes minimum 2? x 8? pressure treated ledger board or other approved engineered materials, all ledger flashing, and staggered lag screw/bolt patterns. if the hole is drilled through the masonry and the bolt is merely passing through the masonry and is in fact secured to the band board of the house, and connecting the ledger to the band board (or other structure within the house) and is not actually fastened to the masonry, but merely passing through without adding any vertical or lateral load, then no engineer is required. in this scenario there is no reason to remove the brick but the integrity of the brick veneer must be maintained. if the bolt is not merely passing through the masonry, but in fact depends upon the masonry for vertical or lateral support, then an engineer is required to document that the masonry can handle the added vertical or lateral load wood/plastic composite deck boards shall be installed in accordance with the manufacturers instructions. janicemjohnston

Valuation: $1,770,000

Client: Hill Dev Llc Notting

Permit #: 347612

2320 Cleary Ct, Louisville, KY 40245

Contractor: Priority Homes, Inc.

Date: Nov 20, 2012

Permit type: New Construction

Description: Lot# 50 lake forest highlands subdivision - section ii - 2968 sf two story brick veneer with 1020 sf finished basement, 196 sf treated wood deck, 41 sf front porch, and 619 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.5.3; handrails r311.5.6; guards r312; emergency egress sec r310; smoke alarms r313. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 11/06/2012 for full build construction. builder has $2500.00 bond post with msd on 11/06/2012 for full build construction. permit #346445 issued on 11/20/2012 for full build construction with stamped and signed approval per tammy markert with letter of credit/savings submitted to transportation department. - hh

Valuation: $29,000,000

Client: Homes Inc Priority

Permit #: 346445

1646 Cowling Ave, Louisville, KY 40205

Contractor: Bornstein Building Company, Inc.

Date: Nov 20, 2012

Permit type: New Construction

Description: 1646 sf story accessory building of wood frame construction of single family dwelling. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 11/09/2012 for full build construction with $2500.00 bond posted on 11/02/2012. - hh

Valuation: $20,000,000

Client: Coalter Linda M Block

Permit #: 347662

16510 Rockcrest View Ln, Louisville, KY 40245

Contractor: Hills Homes Of Kentucky Llc

Date: Nov 21, 2012

Permit type: New Construction

Description: Lot# 41 - brookfield subdivision - section iii - 1661 sf two story brick veneer with 757 sf finished basement, 24 sf treated wood deck, and 377 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.5.3; handrails r311.5.6; guards r312; emergency egress sec r310; smoke alarms r313. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention ond sediment control certificate sighed and approved per jon selch on 11/21/2012 for full build construction. roof trusses load calcs with stamped drawings per engineer gary t. obudzinski #16722. - hh

Valuation: $11,571,500

Client: H Of Ky Inc I

Permit #: 347746

322 Rockcrest View Ct, Louisville, KY 40245

Contractor: Hills Homes Of Kentucky Llc

Date: Nov 21, 2012

Permit type: New Construction

Description: Lot# 59 - brookfield subdivision - section iii - 1701 sf two story brick veneer with 1576 sf finished basement, 24 sf treated wood deck, and 401 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.5.3; handrails r311.5.6; guards r312; emergency egress sec r310; smoke alarms r313. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management stamped and signed approval per john selch on 09/09/2012 with moe of 671.0. roof trusses load calcs with stamped drawings per engineer gary t. obudzinski #16722. - hh

Valuation: $11,200,400

Client: H Of Ky Inc I

Permit #: 347744

328 Lanai Ct, Louisville, KY 40245

Contractor: Daniel Ruckriegel

Date: Nov 22, 2012

Permit type: New Construction

Description: New patio home - lot 9, villas of landis lakes

Valuation: $900,000

Client: Lakes Patio Homes Llc Landis

Permit #: 347835

2713 Razor View Ct, Louisville, KY 40299

Contractor: Daniel Ruckriegel

Date: Nov 22, 2012

Permit type: New Construction

Description: New house - lot 39, razor creek

Valuation: $800,000

Client: Shawn L Oskins Laurel L Oskins

Permit #: 347834

16510 Rockcrest View Ln, Louisville, KY 40245

Contractor: Romanoff Electric Louisville

Date: Nov 26, 2012

Permit type: New Construction

Description: New construction permit; 41 brookfield

Valuation: $150,000

Client: Development Llc Brookfield

Permit #: 347941

1112 Cristland Rd, Louisville, KY 40214

Date: Nov 26, 2012

Permit type: New Construction

Description: Removal of single family dwelling. as per pva, this structure was built in 1944. foundation will als

Client: Groft Nicole Groft Nicholas Lafave

Permit #: 344402

All data is collected from public records. We do not guarantee accuracy of information.