623 Wataga Dr, Louisville, KY 40206
Contractor: Schmitt Construction Co
Date: Aug 11, 2009
Permit type: New Construction
Description: 572 sf one story detached garage on new concrete slab. shall comply to 2007 krc including rafter span r802.5; ceiling joist span r802.4; foundation r403. shall not encroach any easements or required yards. separate permit required for electric. no commercial use allowed. has planning and design verbal approval per karl keeling on 08/11/09. has water management verbal approval per john selch on 08/11/09. - hh
Valuation: $1,600,000
Client: Laurie Ann Rothinghouse
Permit #: 240724
10508 Vista Hills Blvd, Louisville, KY 40291
Contractor: Ware Construction (Henry)
Date: Aug 12, 2009
Permit type: New Construction
Description: Lot 243 little spring farm sec 2c new house br vnr (3,375sqft) 1.5 story unfin/bsmt. (726sqft) att. garage; (192sqft) deck. shall comply to 2007 krc including: ceiling joist span r802.4; floor joist span r502.3: rafter span r802.5; footings r403; foundation walls r404; girder spans r502.5; stairs r311.5; handrails r311.5.6; exterior walls r302; guards r312; emergency egress r310; smoke alarms r313; energy efficiency chapter 11. permanent address shall be posted & visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. ""separate permit required to finish basement" and "bedrooms not allowed in basement without emergency egress per sec r310"". shall comply with ldc single family residential tree requirements in chapter 5 and 10. shall with comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u values in zone 4. shall be posted on or in the electrical distribution panel. also shall provide a written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. property located on sewers & not in flood prone area per the recorded plat. jmj
Valuation: $25,000,000
Client: Homes Priority
Permit #: 240945
14013 Cypress Glen Dr, Louisville, KY 40245
Contractor: Landvest Inc
Date: Aug 12, 2009
Permit type: New Construction
Description: Basement finish u0nit b bldg 16, old henry place 2 of 3 units. br vnr, one story condo with walkout bsmt. shall comply to 2007 kbc, seperate permit required for electric. bedrooms not allowed in bsmt without emer. egress conditional use permit (c.u.p) required for multi family. no commercia luse allowed. . a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u vaules in zone 4. shall be posted on or in the electrical distribution panel. shall provide written manfacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. single family dwelling. conditional use permit required for multi family. jmj
Valuation: $800,000
Client: V Capital Llc Suite 2450 L
Permit #: 240858
3405 Coventry Commons Dr, Louisville, KY 40216
Contractor: L & J Constructors
Date: Aug 13, 2009
Permit type: New Construction
Description: Construction of a new 8-plex.current address is 4510 cane run rd,the address will be changed to 3405 coventry commons dr. draft stopping required every 3000 square feet. all work to meet the requirements of the 2007 kbc.***note: new address will be 3405 coventry place.this address will be issued a foundation only(permit #228506) at this time *** mam
Valuation: $20,005,000
Client: Property Ltd Ptrs Vpl
Permit #: 228497
2219 Winston Ave, Strathmoor Village, KY 40205
Date: Aug 13, 2009
Permit type: New Construction
Description: 240 sf detached garage of wood frame construction. has architect damiel w. mcginnis #23263 stamped drawings. shall not encroach on any easements or required yards. separate permit required for electric. no commercial use allowed. shall comply to 2007 krc including heavy timber construction 2304.10; protection against decay and termites 2304.11. has planning and design verbal approval per karl keeling on 08/13/09. has city of strathmoor village letter of compliance per seila f. kaelin, clerk on 08/12/09 for full build construction. - hh
Valuation: $700,000
Client: Tracy Goodwin
Permit #: 240992
4403 Winter Garden Ct, Louisville, KY 40218
Contractor: A D General Contracting Llc
Date: Aug 13, 2009
Permit type: New Construction
Description: 20 x 8 open covered porch in the rear of a single family dwelling. all work to be in accordance with krc 2007. note; a double 2 x 12 to be used for the headers.
Valuation: $480,000
Client: Brenda L & Crompton An Haley
Permit #: 241013
11612 Top Walnut Loop, Louisville, KY 40229
Contractor: Ball Homes, Llc
Date: Aug 17, 2009
Permit type: New Construction
Description: Lot 319 cooper farms sec 10 new house frame two story (2,614sqft) slab. (412sqft) att. garage; no de
Valuation: $11,000,000
Client: Homes Llc Ball
Permit #: 241237
15801 Northville Pl, Louisville, KY 40245
Contractor: Elite Homes Inc
Date: Aug 17, 2009
Permit type: New Construction
Description: Lot 40 waterstone park new house br vnr one story (2,132sqft) non-walkout unfin/bsmt. (512sqft) att. garage; no deck. shall comply to 2007 krc including: ceiling joist span r802.4; floor joist span r502.3: rafter span r802.5; footings r403; foundation walls r404; girder spans r502.5; stairs r311.5; handrails r311.5.6; exterior walls r302; guards r312; emergency egress r310; glazing r308; smoke alarms r313; energy efficiency chapter 11. permanent address shall be posted & visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. ""separate permit required to finish basement" and "bedrooms not allowed in basement without emergency egress per sec r310"". shall comply with ldc single family residential tree requirements in chapter 5 and 10. shall with comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u values in zone 4. shall be posted on or in the electrical distribution panel. also shall provide a written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. property is located on sewers & not in flood prone area per the recorded plat. jmj
Valuation: $16,726,800
Client: Cheryl Hettinger
Permit #: 241315
731 S 43Rd St, Louisville, KY 40211
Date: Aug 18, 2009
Permit type: New Construction
Description: 400 sf one story detached garage on slab. shall comply to 2007 krc including rafter span r802.5; ceiling joist span r802.4; foundation r403. shall not encroach any easements or required yards. separate permit required for electric. no commercial use allowed. - hh
Valuation: $1,000,000
Client: Stanton A & Natalie Neil
Permit #: 241464
7111 Whipple Rd, Louisville, KY 40272
Contractor: Robertson Built Homes, Inc
Date: Aug 20, 2009
Permit type: New Construction
Description: Foundation only for new single family dwellling. all constr. shall comply w/2007 ky. bldg. code. note: the holder of such permit for the foundation or other parts of a bldg. or structure shall proceed at the holder's own risk with the bldg. operation & without assurance that a permit for the entire structure will be granted. msd approval for foundation only on 8-20-09. works approval dated 8-18-09. pleasure ridge fire dept. approval dated 8-17-09. aw
Valuation: $1,500,000
Client: Robertson Built Homes
Permit #: 241823
9101 Visser Dr, Louisville, KY 40299
Contractor: Stonelake Homes Llc
Date: Aug 20, 2009
Permit type: New Construction
Description: Infill-minor plat tract 2- one story 2,338 sf, frame with unfin w/o bsmt., 390 sf deck, 157 sf covered front porch, and 653 sf att. garage. shall comply to 2007 krc including, ceiling joist spans r802.4; floor joist span r502.3; rafter span r802.5; footings r403; foundation walls r 404; stairs r311.5; handrails r311.5.6; guards r312; emer. egress sec r310; smoke alarms r313; wall bracing r602.10; energy efficiency chapter 11. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish bsmt. bedrooms not allowed in bsmt without emer. egress per sec r310. shall comply to ldc single family residential tree requirements in chapter 5 and 10. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values and u-factors in zone 4, shall be posted on or in the electrical distribution panel. shall comply with hvac sizing as specified in m1401.3. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector. has all beam load calcs except front porch. shall deliver front porch beam load calcs, front porch column load detail and steel beam size detail to field inspector. has minor plat db#07709 pg0898. has transportation stamped approval. has fern creek f.d. stamped approval. has water mgt stamped approval. has health dept stamped approval for permit #s09-40361. this is an energy star home. certificate of occupancy shall be witheld until energy star certificate of completion is delivered to field inspector. mi
Valuation: $22,000,000
Client: William C & Amanda Young
Permit #: 241742
7232 Daisy Ave, Louisville, KY 40258
Contractor: Cmh Inc
Date: Aug 20, 2009
Permit type: New Construction
Description: 2176 sf foundation for manufactured home on crawl 160 sf front porch 64 attach deck .** foundation is at owners risk per sec 106.3.3 krc.** has been reviewed by planning and design # 12915.based on lojic and submitted setbacks meet 2a set backs.shall comply to 2007 krc including foundations r403, footers r403,foundation anchorage r403.1.6. shall not encroach any easements, right of ways or required yards. separate permit required for electric. no commercial use allowed. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values factors in zone 4, shall be posted on or in the electrical distribution panel.-- separate permit for full build ---hud documentation was satisfied per dave marchal and george pate .separate permit for full build.-cc
Valuation: $8,000,000
Client: Shelt R & Jessie Decker
Permit #: 240375
4156 Scott St, Louisville, KY 40213
Contractor: Cmh Inc
Date: Aug 20, 2009
Permit type: New Construction
Description: 2440 sf foundation one story manufactured home on crawl.128 sf front porch 64 sf deck .shall comply to 2007 krc including foundations r403, footers r403,foundation anchorage r403.1.6. shall not encroach any easements, right of ways or required yards. separate permit required for electric. no commercial use allowed. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values factors in zone 4, shall be posted on or in the electrical distribution panel. ** foundation is at owners risk per sec 106.3.3 krc.** has been reviewed by planning and design # 12987.based on lojic and submitted setbacks meet 2a set backs. see permit # 205719 for wrecking.hud documentation was satisfied per dave marchal and george pate .separate permit for full build.-cc
Valuation: $8,000,000
Client: George M Raddish
Permit #: 239391
7812 Westbrook Rd, Louisville, KY 40258
Contractor: Jagoe Homes, Inc.
Date: Aug 20, 2009
Permit type: New Construction
Description: Lot 3 green ridge estates new house frame one story (1,361sqft) on slab. (416sqft att. garage) & (20sqft porch) shall comply to 2007 krc including: ceiling joist span r802.4; floor joist span r502.3: rafter span r802.5; footings r403; foundation walls r404; girder spans r502.5; stairs r311.5; handrails r311.5.6; exterior walls r302; guards r312; emergency egress r310; smoke alarms r313; energy efficiency chapter 11. permanent address shall be posted & visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. ""separate permit required to finish basement" and "bedrooms not allowed in basement without emergency egress per sec r310"". shall comply with ldc single family residential tree requirements in chapter 5 and 10. shall with comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r and u values in zone 4. shall be posted on or in the electrical distribution panel. also shall provide a written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. no commercial use allowed. has moe verified full constuction 8-20-09 per john selch. jmj
Valuation: $6,800,000
Client: Homes Inc Jagoe
Permit #: 241747
1400 S Hurstbourne Pky, Hurstbourne, KY 40222
Contractor: Lichtefeld, Inc.
Date: Aug 21, 2009
Permit type: New Construction
Description: Ken towery's retail tire center-8400 total sf of one story block ten bay tire retail center on slab with an alignment pit. 1020 sf is merchantile use group and 7380 sf is storage s1 use group. shall comply with ansi a117.1 & 2007 kbc including: emergency power 1006; exit signs 1011; accessibility signage 1110; fire barriers 706; safety glazing 2406; trusses 2303.4; masonry construction 2104; steel connections 2204; repair garages 406.6; storage racks 2208; energy efficiency chapter 13. shall comply with 2006 international fire code-repair garages section 2211. alignment rack and 9 bay lifts to be supplied and installed by others. has comcheck mechanical compliance certificate, interior lighting certificate and envelope compliance certificate. has architect roberto bajandas stamped plans. has engineers james forst, joseph metzmeier, scott hannah, and engineer kevin aldred stamped plans. see luapp #11703 for approved district development plan stamp, zoning change and ldc waivers. seperate permits required for signage, plumbing, hvac, electric, and fire detection. shall deliver truss load calcs to field inspector. 660 gallon maxium interior storage for class iiib (motor oil) combustible liquid storage system, connected to an approved piping system, provided it complies to the international fire code per 2007 kbc table 307.1(1) and kbc 311.2. has tire storage affadavit to comply with kbc 903.2.8.2. shall comply with all binding elements on docket #11703. no certificate of occupancy is to be issued, without a (state of ky. ohbc hazardous materials section) above ground storage tank permit for petroleum products issued and a copy delivered to the field inspector. see parking lot permit #249472. has landscaping chapter 10 stamped approval. has water mgt stamped approval. has public works stamped approval. has city of lyndon fire dept stamped hydrant approval. no certificate of occupancy without msd approved sewer connection and a paid up msd capicity fee per john selch. has city of hurstbourne letter of compliance #09-18. has ky. transporataion cabinet encroachment permit #05-0590-09. mi
Valuation: $51,508,800
Client: Real Properties Plus, Llc
Permit #: 239980
207 Cornell Pl, Saint Matthews, KY 40207
Contractor: Primera Llc
Date: Aug 21, 2009
Permit type: New Construction
Description: 30 sf two story cantilever addition of wood frame construction. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r317. has city of st. matthews letter of compliance per james birch on 08/18/09 has metro board of zoning adjustment case no: b-13006-09 approved per steve hendrix on 08/17/09 for full build construction. - hh
Valuation: $2,000,000
Client: Bryan D Schmitt
Permit #: 241858
6718 Weather Vane Dr, Louisville, KY 40299
Contractor: Dominion Homes Inc
Date: Aug 21, 2009
Permit type: New Construction
Description: Lot 271 billtown farms "kingston" two story br element unfin walkout bsmt with 432' att garage. (elevation d with 5th bedroom) no deck, vaults or retaining walls. shall comply with ldc 6.2.6b for sidewlks; chapters 5 & 10 for tree requirements & 2007 krc: header r502; energy conservation r1102; separate permit required to fin bsmt: bedrooms not allowed without emergency egress r310. property is on sewers and not in flood prone area. shall not encroach any easements or required yards. permanent address shall be posted and visible from street prior to occupancy. window instillation & engineer members including lvl beams & trusses: documentation to be provided to inspector on site. permanent energy efficiency r-values shall be posted on or in the electrical distribution panel. dmt
Valuation: $12,000,000
Client: Brandon Moore
Permit #: 241007
3804 Staebler Ave, Saint Matthews, KY 40207
Contractor: Christopher W Dixon
Date: Aug 21, 2009
Permit type: New Construction
Description: 409sf family room one story frame addition on crawl with 84 sf att deck . shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313; energy efficiency chapter 11, girder span r502.5; decks 502.2.2.2; protection against decay r319.. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 along with lvl load calcs. to be delivered to the field inspector. has city of st mathews approval.-cc
Valuation: $5,000,000
Client: Jane Walker Simpson
Permit #: 240730
300 Monohan Dr, Saint Matthews, KY 40207
Contractor: Bob Wells Construction Co In
Date: Aug 24, 2009
Permit type: New Construction
Description: 300 sf breeze way renovation with att 60 sf pergola ( no additional weight to be applied on pergola) 73 sf interior renovation on first floor to move non load bearing wall ,and bathroom 558 sf the second floor addition ( for 2 bedroom and bath) on existing footers and foundation are at owner own risk and subject to the building inspectors discretion . addition. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313; energy efficiency chapter 11. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values and u values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. has lvl load calcs. has city of st mathews approval.-cc
Valuation: $11,000,000
Client: J Key & Sharon T Schoen
Permit #: 240722
8015 Adams Run Rd, Louisville, KY 40228
Date: Aug 24, 2009
Permit type: New Construction
Description: 384 sf one story roof over existing patio addition of wood frame construction. shall not encroach any easements or required yards. separate permit required for electric. shall comply to 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r317. - hh
Valuation: $500,000
Client: James C & Mary E Olrich
Permit #: 242022