Contractors DirectoryInformation on every contractor in United States

New Construction Permits in Hagerstown, MD

18016 Sand Wedge Drive, Hagerstown, MD 21740

Contractor: Crampton Paul Jr

Date: Mar 11, 1992

Permit type: New Construction

Description: Construct roof over patio slab

Fee: $25.76 paid to Washington County, MD

Client: Mayhue James F & Grace M

Parcel #: 05702057300146

Permit #: PRJ92-0430

19503 Thomas Drive, Hagerstown, MD 21740

Contractor: Foremost Industries

Date: Mar 16, 1992

Permit type: New Construction

Description: 35x 52 1 story modular dwelling,full basement, .himney for wood stove . . . . . 6-29-92-slab-grm--bstm slab ok to pour. vap barr & wire in place 7-2-92-slab-grm-ok to pour, wire & rebar in place.7-8-92-sewer conn-elp--told john shank jr to place gravel around pipe. 7-17-92 frame se no req for front porch. dbl 2x8s w/trusses 7-17-92 final ap release grm/vpw

Valuation: $5,800,000

Client: Harne John W & Shirley A

Parcel #: 06302025600026

Permit #: 92-1579

13106 Hyacinth Court, Hagerstown, MD 21742

Date: Mar 16, 1992

Permit type: New Construction

Description: 1 story dwelling,full basement,2-car garage,no chimney 4-30-92-ftr & setback-jrs--(1)location survey required prior to pouring footer. (2) 2 runs 1/2 steel reqd on garage footer where lintel will be placed 4-6" long 4-30-92-ftr-jrs--ok per randy on survey. will submit before block starts. 5-08-92-othr-jrs--pre-foundation. left notice still needed survey before start of framing. 6-19-92-frm-jrs--flashing installed on top of block. 8-21-92-fnl elec-jgc--need #4 ground wire from panel to cold water pipe on water heater. u&o/kad

Valuation: $5,600,000

Client: Oliver John R Co Inc

Parcel #: 03802086000008

Permit #: 92-1588

19503 Thomas Drive, Hagerstown, MD 21740

Contractor: Foremost Industries

Date: Mar 16, 1992

Permit type: New Construction

Description: 24x 24 attached garage,frame construction, slab,shingle roof,electrical . . . . . 7-2-92-slab-grm--ok to pour. vap barr, wire and rebar in place. 7-17-92 final ap release grm/vpw

Valuation: $1,700,000

Client: Harne John W & Shirley A

Parcel #: 06302025600026

Permit #: 92-1582

19517 Thomas Drive, Hagerstown, MD 21740

Date: Mar 17, 1992

Permit type: New Construction

Description: 2 story dwelling, full basement, no fireplace or chimney, 36x28, attached 2 car garage lot 24 - highlands of landis spring 4-14-92-ftr & entr-grm--(1) driveway entrance not to co standard. correct (2) except for front bstm footer, all other bstm footers are too narrow per plans that call for a full 20" width. correct. (3) four bstm pier footers to be 32" sq correct. (4) see dwg 7 0f 7 of bldg plans. all #4 rebar to be contineous. please add additional bars from garage footer to bonus room footer & bulk head as required, (west end). lintels will be ok at side porch to bstm wall on east end at least 12 to 18 inches of bearing. 5-1-92-fnd-grm--ok to backfill drains to gravity. 5-12-92-slab-jrs--garage wire & poly plus 1/2" rebar 3 each way, front porch poly & wire 5-19-92 drive co no pipe frame ap ok to close in 1). need metal bearing plates at girder beam in basement 7-7-92 drive ap release final co 1) final elec 2) vent dryer 3) caulk bstm window 4) handrail & guar rail 7-8-92 final ap release grm/vpw

Valuation: $8,000,000

Client: Mauck Timothy M & Loretta D

Parcel #: 06302025600024

Permit #: 92-1640

13608 Daisy Circle, Hagerstown, MD 21740

Date: Mar 17, 1992

Permit type: New Construction

Description: 12x14 concrete patio w/ footers and sidewalk . . . . . . 12-18-92-fnl bldg-lar closed 12-31-92 ysh

Fee: $20.00 paid to Washington County, MD

Client: Keener Stuart B & Karan A

Parcel #: 02414111400015

Permit #: PRJ92-0474

13608 Daisy Circle, Hagerstown, MD 21740

Date: Mar 17, 1992

Permit type: New Construction

Description: 12x14 concrete slab w/ footers and sidewalk 4-27-92-fnl bldg-lar--a min 3x3 landing is reqd at the egress door. the landing shall not be more than 81/2" below the top of the threshold. . . . 12-18-92-final bldg-lar closed 12-31-92 ysh

Valuation: $150,000

Client: Keener Stuart B & Karan A

Parcel #: 02414111400015

Permit #: 92-1628

1210 Rose Hill Avenue, Hagerstown, MD 21740

Date: Mar 27, 1992

Permit type: New Construction

Description: 12x 12 deck . . . . . . . . 4-10-92 footer & setbacks ok 4-20-92 final ok crf/vpw

Valuation: $92,000

Client: Harrell Jerry D & Barbara S

Parcel #: 49100160419022

Permit #: 92-1910

1210 Rose Hill Avenue, Hagerstown, MD 21740

Date: Mar 27, 1992

Permit type: New Construction

Description: 12x12 deck on rear of duplex . . . . . . . 4-10-92 footer & setbacks ok 4-20-92 final ok crf/vpw

Valuation: $90,000

Client: Harrell Jerry D & Barbara S

Parcel #: 49100160419022

Permit #: 92-1909

1210 Rose Hill Avenue, Hagerstown, MD 21740

Date: Mar 27, 1992

Permit type: New Construction

Description: 12x12 deck on rear of duplex . . . . . . . 4-10-92 footer & setbacks ok 4-20-92 final ok crf/vpw

Valuation: $90,000

Client: Harrell Jerry D & Barbara S

Parcel #: 49100160419022

Permit #: 92-1908

17909 Bluebell Court, Hagerstown, MD 21740

Date: Mar 30, 1992

Permit type: New Construction

Description: 2 story single family dwelling

Client: Lee Charles M & Joyce R

Parcel #: 02414109600021

Permit #: 92-1933

17909 Bluebell Court, Hagerstown, MD 21740

Date: Mar 30, 1992

Permit type: New Construction

Description: 2 story dwelling,full basement,attached 2 car garage frame construction patio 14x12 on rear . . . . . 5-18-92-fnd-lar--apply tar & complete drain tile. 6-29-92-frm-jrs-(1)blocks at bulkhead are to be flat way for draftstopping (2) approved plans should be at this site. tim give me a call in the morning. 8/13/92-final electrical-lam-co-need disconnect at furnace or lock out breaker 8-14-92-fnl bldg-lar--add guardrails & handrails in basement stairway. 8/17/92 final-ok-release-lar 8/18/92 u&o-slt

Valuation: $14,200,000

Client: Lee Charles M & Joyce R

Parcel #: 02414109600021

Permit #: 92-1931

14436 Marsh Pike, Hagerstown, MD 21742

Date: Mar 31, 1992

Permit type: New Construction

Description: 24x 27 garage addition with 6x 24 breezeway, garage/slab,breezeway/crawl space 5-29-92-setbacks-jrs--okd to lintel has steel. will pour block wakk okd. 6-9-92-slab-jrs--pouring slab down thur all couses of block to tie together. 12-22-92 final building approved jrs

Valuation: $2,000,000

Client: Burkholder David H

Parcel #: 01121002400000

Permit #: 92-1955

13605 Daisy Circle, Hagerstown, MD 21740

Date: Apr 3, 1992

Permit type: New Construction

Description: 2 sty dwelling,2 car attached garage,full basementgas fireplace with chimney, shingle roof . . . . 7/29/92-framing-lar-co-obtain rough mech-add joist hangers 7-31-92-r/mech-gla--stud space return not complete9-25-9-2-fnl mech-gla--gas log lighter-x/o cut-off visible-need info from thompsons. 9/29/92 given ok to issue u&o per rmd-slt (over) 9/29/92 finals are to be made today,will need to gather final paperwork in the a.m./slt

Valuation: $8,900,000

Client: Zampelli Michael S

Parcel #: 02414111400011

Permit #: 92-2039

925 Security Rd, Hagerstown, MD 21742

Date: Apr 7, 1992

Permit type: New Construction

Description: 14x32 pre-fab storage shed on stone pad for residential use 1-11-93 setbacks approved 1-11-93 final approved 1-11-93 u & o issued by kld

Valuation: $290,000

Client: Tharp Albert G

Parcel #: 038190835A001

Permit #: 92-2144

11009 Parkwood Drive, Hagerstown, MD 21742

Date: Apr 10, 1992

Permit type: New Construction

Description: 2 story dwelling,full basement,2 car garage attached chimney for fireplace rear deck 6-2-92-ftr-jrs--(1)app plans call for footer to be 10" deep, why was not changed to 8" when submitted? (2)randon venting is it installed per drawing? do not pour footer and slab until corrs are made or letter stating changes is submitted. 6-2-92-setback-jrs--temp only. survey reqd or no foundation insp. pouring at builders own risk. 6-2-92-ftr-jrs--footer per drawings 2 runs 1/2" steel thru out footer drains install to sump and gravity basket is radon bucket. 6-16-92-(1)house only. plans revised okd in field (2)garage footer poured no insp. advised steel was inst. call earl and meet about garage. (3)tar & drains in place no water proofing. (4)raydon bucket used and vents inst. (5)also drains go to gravity and bucket. 9-16-92-frm-jrs--(1)jackstuds needed under girder truss. (2)joist hanger on double truss in the master room. corrd pm 1-22-93 streets ok ent complete grading ok jrs/ vpw

Valuation: $18,000,000

Client: Spies Jay A

Parcel #: 05022159400052

Permit #: 92-2274

19242 Olde Waterford Rd, Hagerstown, MD 21742

Date: Apr 13, 1992

Permit type: New Construction

Description: 2 story dwelling,full basement,2-car attached garage,12x 24 deck,2 full baths,2 half baths 5-11-92-ftr-jrs--2 runs 1/2" steel per plans required ok. 5-22-92-fnd-jrs--drain installed. left notice about sump. 6/16/92-slab-jrs-ap basement poly installed using fiber crete garage poly & steel 2 each way 1/2" rebar pier in place for olumn also tamp fill in gar note: advised flashing and weep holes are required 7-7-92-r/elec-lam--lights at tub in master bedroom bath, must have at least 5 from tub or recess above the tub. recpt & switch to be at least 5 from tub. 7-14-92-mech-gla--(1)no electric devices allowed in return space ie(3-way switch box). (2)bath fan exhaust not complete to outside. (3) stud space return serving single floor not blocked off with 2" nominal lumber directly above register opening. (4)stud space returns crossing (2) two firestop areas. (5)flex duct runs joined together must use metal sleeve per smacna cont standards. (6)metal & flex run in basesment needs proper support under metal section. (7) runs in basement not complete. 7-30-92-frm-jrs--(1)app. building plans are to be on site (r.110). (2)fill blocking not inst below bulk head in kitchen (402.7). (3)one joist hanger missing in bstm. (4)some holes missed thur top plates for firestopping. (5)jack post needs installed under girder for truss upstairs (6)where is sump pump basket? (7) 4" mim curb in garage at steps. 8-13-92-frm-grm--ok to close in except at stair- well in garage to basement. 12-22-92-fnl mech-gla--too early no switches in place to test fans or a/c unit. 1-29-93-fnl plum-rwe--p 111.1 obtain plumb permit for water conditioner (ever-soft water cond) (2) p 1506.3 flue pipe from water heaters must rise 1/4" per foot to chimney. 2/19/93 certified letter mailed advising what final are needed. deadline 3/22/93 2/22/93 received return receipt 3-22-93-fnl bldg-new deadline may 1, 1993. (1) add 2 more 2 x 4 at basement steps. (2) permit required for wood stove. (3)finish brick & steps outside. 4/4/94 final bldg. rails installed on front steps release jrs u&o/kas

Valuation: $12,000,000

Client: Barron Woodrow A & Vickie L

Parcel #: 02418112800010

Permit #: 92-2287

19115 Bonnie Briar Ln, Hagerstown, MD 21742

Contractor: Quality Homes Of Maryland, Llc

Date: Apr 16, 1992

Permit type: New Construction

Description: Screened porch 18x14 on slab frame construction

Valuation: $1,000,000

Client: Boyd J Michael

Parcel #: 02424023500019

Permit #: 92-2461

19115 Bonnie Briar Ln, Hagerstown, MD 21742

Contractor: Quality Homes Of Maryland, Llc

Date: Apr 16, 1992

Permit type: New Construction

Description: Garage foyer screened porch

Fee: $57.60 paid to Washington County, MD

Client: Boyd J Michael

Parcel #: 02424023500019

Permit #: PRJ92-0754

19115 Bonnie Briar Ln, Hagerstown, MD 21742

Contractor: Quality Homes Of Maryland, Llc

Date: Apr 16, 1992

Permit type: New Construction

Description: 24x24 garage on slab,frame construction wood siding shingle roof. attached to breezeway. 5-13-92-fnd-jrs--4 piers in center to support slab. . . . 6-25-92-w/service-rwe--to be finished by a downs

Valuation: $2,500,000

Client: Boyd J Michael

Parcel #: 02424023500019

Permit #: 92-2459

All data is collected from public records. We do not guarantee accuracy of information.