Contractors DirectoryInformation on every contractor in United States

Kitchen Remodeling Permits in Moore, MT

2614 Farren Hill Rd, Moore, MT 59464

Sponsored by Rehold
Information About Property

Date: Dec 13, 2013

Permit type: Kitchen Remodeling

Description: Homeowner sf/new troyer self - 12/30/13 met with ownerno service at this time - wired for future usereminders210.52(a) (2): outlet wall space: a wall space shall include any wall space 2 feet or more in width (including space measured around corners) and unbroken by doorways, fireplaces, and similar openings. 210.11(c) (1): small appliance circuits: two or more 20 amp small-appliance branch circuits shall be provided for all receptacle outlet specified by 210.52(b). the two or more small appliance circuits shall have no other outlets. 210.52(c) (1): kitchen countertops: a receptacle outlet shall be installed at each wall countertop space that is 12 inches or wider. receptacle outlets shall be installed so that no point along the wall is more than 24 inches measured horizontally from a receptacle outlet. 210.52(c) (2): island counter spaces: at least one receptacle shall be installed at each island countertop space with a long dimension of 24 inches or greater and a short dimension of 12 inches or greater.210.52(c) (3): peninsular countertop spaces: at least one receptacle outlet shall be installed at each peninsular countertop space with a long dimension of 24 inches or greater and a short dimension of 12 inches or greater. a peninsular countertop is measured from the connecting edge.210.52(c) (4): separate countertop spaces: countertops separated by rangetops, refrigerators, or sinks shall be considered as separate countertop 210.52(e) (3): balconies, decks, and porches: balconies, decks, and porches that are accessible from inside the dwelling unit shall have at least one receptacle outlet installed within the perimeter of the balcony, deck, or porch. the receptacle shall not be located more than 6 feet above the balcony, deck, or porch. international residential code: 316: smoke detector requirements: smoke detectors shall be installed in each sleeping room, outside of each sleeping area and on each additional story of the dwelling. all detectors shall be interconnected such that the actuation of one alarm will actuate all the alarms in the dwelling. the power source for the required smoke detectors shall be utility power with battery back-up.

Fee: $200.00 paid to State of Montana

Client: Troyer, Joe

Permit #: 2013-ERES-MTN-007415

All data is collected from public records. We do not guarantee accuracy of information.