Contractors DirectoryInformation on every contractor in United States

Kitchen Remodeling Permits in Columbus, OH

1260 Le Anne Marie Cir, Columbus, OH 43235

Contractor: Accurate Electric Construction Inc.

Date: Aug 22, 2012

Permit type: Kitchen Remodeling

Description: 1260 le anne marie circle - rbld1223634 kitchen remodel and dining room remodel - 24 light fixtures, 10 switches, 11 receptacles, 2 motors/appliances, 3 smoke detectors

Valuation: $390,000

Fee: $200.00 paid to City of Columbus, Ohio

Client: Fortney Carl J & Mary J

Parcel #: 010172921

Permit #: ELEC1227046

1437 Wendell Ave, Columbus, OH 43222

Date: Aug 22, 2012

Permit type: Kitchen Remodeling

Description: Expired permit#elec1123537 1 inspection for final approved to issue to allphase for final 1 inspection @ 75.00 per tim k 1437 wendell lave alter 2 story frame, 1 family dwelling to repair fire damage per report #35-h-382-338 dated 7-12-11. fidm1121256 rewire kitchen 1 light fixture 4 switches 4 recps 3 motors/applicances total 12

Fee: $75.00 paid to City of Columbus, Ohio

Client: Thacker Hershel

Permit #: ELEC1227098

768 Breezedale Pl, Columbus, OH 43213

Contractor: Waibel Electric Company

Date: Aug 23, 2012

Permit type: Kitchen Remodeling

Description: 768 breezedale place install lights in kitchen, paddle fans in br, replace panel, move 6 switches, install 6 outlets. (no plans required per g. tudor)

Valuation: $200,000

Fee: $200.00 paid to City of Columbus, Ohio

Client: Woodrow L. Wilson

Parcel #: 010140028

Permit #: ELEC1227388

636 Harrisburg, Columbus, OH 43223

Contractor: Interstate Construction Company

Date: Aug 31, 2012

Permit type: Kitchen Remodeling

Description: 636 harrisburg pike plan approval: final. conditions of the plan approval: none. plan approval exclusions: awnings and signage will be under a separate permit. reviewed for compliance under: 2011 obc and icc/ansi a117.1-2009 use / occupancy group: drive-thru restaurant / b construction type: v-b description of the work: new 1334 sq ft drive-thru tim hortons restaurant. kitchen exhaust hoods are all type ii. separate permits reqd for plmb, elec, mech. conditions, limitations, variances and special stipulations of the occupancy: b use group is based on occupant load less than 50. single toilet room is permitted based on total occupant load of 15. in b use, total occupant load for toilet fixture requirements does not include patio. a maximum of two tables (8 seats) are permitted on the patio. cooler (vestibule) size approved as unoccupied equipment. design occupant load: 15. maximum capacity card: not required. fire suppression systems: none. fire alarm system: none. storage: not applicable. record / history: new building.

Valuation: $45,000,000

Fee: $1,500.00 paid to City of Columbus, Ohio

Client: Davis Center Land Prtnrs

Parcel #: 010126626

Permit #: CBLD1228484

1180 Leicester Pl, Columbus, OH 43235

Contractor: Craftsman Service Co Llc

Date: Sep 6, 2012

Permit type: Kitchen Remodeling

Description: 1180 leicester alt 2 sty frm, 1 fam dwg by remodel kitchen per plan, add island, remove soffits, new cabinets, separat electric permit needed, inspections are required

Valuation: $2,000,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Cheung Fanny V

Parcel #: 610200607

Permit #: RBLD1229132

6011 Wexford Park Dr, Columbus, OH 43228

Date: Sep 10, 2012

Permit type: Kitchen Remodeling

Description: 6011 wexford park drive alter 2 story frame, single family dwelling by adding 1st floor 1/2 bath in existing closet, remove part of interior kitchen wall to make pass through, separate mechanical, electrical and plumbing permits needed, inspection required.

Valuation: $350,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Seward Ryan A Seward Erin C

Permit #: RBLD1229461

5801 Loganwood Rd, Columbus, OH 43229

Contractor: Great Scott Kitchens & Remodeling, Llc

Date: Sep 12, 2012

Permit type: Kitchen Remodeling

Description: 5801 loganwood rd install new kitchen cabinetry, countertops, flooring, drywall, etc. includes removal of existing dining room wall and existing cabinet drops/soffits per approved documents.

Valuation: $4,500,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Colleli Mark A Colleli Mary H

Parcel #: 010140090

Permit #: RBLD1229766

1180 Leicester Pl, Columbus, OH 43235

Contractor: Elite Electric Services

Date: Sep 13, 2012

Permit type: Kitchen Remodeling

Description: 1180 leicester rbld1229132 remodel kitchen 8 light fixtures 3 receptacles 11 total

Valuation: $82,000

Fee: $200.00 paid to City of Columbus, Ohio

Client: Cheung Fanny V

Parcel #: 610200607

Permit #: ELEC1230100

2036 Millbrook Way, Columbus, OH 43219

Contractor: Bill Clark Electric

Date: Sep 14, 2012

Permit type: Kitchen Remodeling

Description: 2036 millbrook way kitchen, bath, basement remodel in single family dwelling rbld1207951

Valuation: $400,000

Fee: $200.00 paid to City of Columbus, Ohio

Client: Brown Thomas

Parcel #: 010027984

Permit #: ELEC1230230

1582 Simpson Dr, Columbus, OH 43227

Contractor: Benchmark Restoration Services Llc

Date: Sep 17, 2012

Permit type: Kitchen Remodeling

Description: 1582 simpson dr replace paint and drywall in kitchen and dining room that was damaged by fire alter 2 story frame, split level, 1 family dwelling to repair fire damage per report number brathwaite wm sm dated 8-22-12, required mep's must be obtained and inspected seperatly.

Valuation: $2,774,800

Fee: $290.00 paid to City of Columbus, Ohio

Client: Brathwaite William Jr & Debra

Parcel #: 010106258

Permit #: FIDM1230351

1018 Birchmont Rd, Columbus, OH 43220

Date: Sep 17, 2012

Permit type: Kitchen Remodeling

Description: 1018 birchmont alter 2 story, split level, 1 family dwelling to remodel kitchen area. required mep's must be obtained separately

Valuation: $1,600,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Robbins Thomas G & Frances G

Parcel #: 010135492

Permit #: RBLD1230341

3505 Fremont St, Columbus, OH 43204

Date: Sep 18, 2012

Permit type: Kitchen Remodeling

Description: 3505 fremont st units a-d paint drywall repair minor electric and plumbing kitchen cabinets flooring new windows fix concret stoops

Valuation: $3,000,000

Fee: $1,000.00 paid to City of Columbus, Ohio

Client: Fremont Townhomes

Parcel #: 570126629

Permit #: INTR1230571

639 Evergreen Ter, Columbus, OH 43228

Contractor: Ceqart Construction Group Inc

Date: Sep 24, 2012

Permit type: Kitchen Remodeling

Description: 639 evergreen terrace alt 1 sty frm, 1 fam dwg by remodel per plan, separate mep's needed, reroof and reside to code, add new front porch and rear deck, new doors and windows house will now be 2 bed, 1 bath with living room, kitchen and 1st safloor laundry, r13 walls, r30 ceiling as needed, inspections are required

Valuation: $9,000,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Homes On The Hill Cdc

Parcel #: 570150325

Permit #: RBLD1231372

90 Delray Rd, Columbus, OH 43216

Contractor: Accu-Spec Consulting & Construction Services Llc

Date: Sep 25, 2012

Permit type: Kitchen Remodeling

Description: 90 delray st - 1 fam dwell 6/13/13 revision to rbld1231444 - move laundry from the north side of basement to the west side, show engineering of valley rafter. alter 1 story frame, 1 family dwelling to renovation interior to insulate to r-13 in walls, r-30 in ceilings, replace 15 windows, reroof dwelling, add seperation walls in basement for storage, raise ceiling in kitchen area, remodel kitchen and bath, and add bath in basement. all required mep's must be obtained by licensed mep contractors.

Valuation: $6,500,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Brumfield Jacqueline L

Parcel #: 010113492

Permit #: RBLD1231444

3289 Milton Ave, Columbus, OH 43202

Contractor: Hope Restoration

Date: Oct 2, 2012

Permit type: Kitchen Remodeling

Description: 3289 milton avenue alter 2 story frame, 1 family dwelling to remodel kitchen and remove non-load bearing wall. required meps must be obtained separately.

Valuation: $2,000,000

Fee: $265.00 paid to City of Columbus, Ohio

Client: Louis Chaney

Parcel #: 010006222

Permit #: RBLD1232179

3289 Milton Ave, Columbus, OH 43202

Contractor: Rci Electrical Solutions Llc

Date: Oct 5, 2012

Permit type: Kitchen Remodeling

Description: 3289 milton avenue install electric for kitchen remodel kitchen and replace knob and tube wiring in the attic (8 light fixtures, 7 switches, 12 receptacles, 7 smoke detectors) rbld1232179

Valuation: $300,000

Fee: $200.00 paid to City of Columbus, Ohio

Client: Louis Chaney

Parcel #: 010006222

Permit #: ELEC1232805

4822 Timberwood Dr N, Columbus, OH 43228

Date: Oct 17, 2012

Permit type: Kitchen Remodeling

Description: 4822-4828 timber wood dr north building permit to make structural repairs in all units of a multi fam bldg along with replacement of water heaters, hvac units, condensors, kitchen sinks and electrical circuits and panels. rough and final structural inspections will be requird to complete this permit. a seperate mechanical permit will be required for assocaited mechanical work. a seperate electrical permit will be required for assocaited electrical work. a seperate plumbing permit will be required for assocaited plumbing work. vb r-2

Valuation: $6,500,000

Fee: $300.00 paid to City of Columbus, Ohio

Client: Lb Rpr I Asset Holdings Llc

Permit #: INTR1234190

4840 Timberwood Dr N, Columbus, OH 43228

Date: Oct 17, 2012

Permit type: Kitchen Remodeling

Description: 4840 - 4846 timber wood dr north building permit to make structural repairs in all units of a multi fam bldg along with replacement of water heaters, hvac units, condensors, kitchen sinks and electrical circuits and panels. rough and final structural inspections will be requird to complete this permit. a seperate mechanical permit will be required for assocaited mechanical work. a seperate electrical permit will be required for assocaited electrical work. a seperate plumbing permit will be required for assocaited plumbing work. vb r-2

Valuation: $6,500,000

Fee: $1,200.00 paid to City of Columbus, Ohio

Client: Lb Rpr I Asset Holdings Llc

Permit #: INTR1234191

6165 Polo Dr W, Columbus, OH 43229

Date: Oct 19, 2012

Permit type: Kitchen Remodeling

Description: 6165 polo dr replacement of expired permit frdm1036449 need rough framing & final- per dale shumaker repairs to fire damaged unit; remove all drywall - walls & ceiling; replace with 1/2-in gwb; replace kitchen cabinets, vanities, shelving; new interior doors as required - no exterior windows or doors included; new plumbing fixtures as required; all hvac & electric devices requiring repair or replacement shall comply with current codes; any additional new wiring or work on new equipment or devices - not replacement - shall require plans for review & approval code: (2007 obc) type (v-b (602.5)) use (r-2 (310.1)) design occupant load: no change or not applicable certificate of occupancy :(new building) (alteration) ( ) ( ) conditions, limitations, variances and special stipulations of the occupancy: none. fire suppression systems: sprinkler system: none hazard class: not applicable riser demand: not applicable standpipe system: none alternative system: none fire alarm system: none storage: not applicable commodity class: description: aisle width: maximum height storage: live load: not applicable

Fee: $300.00 paid to City of Columbus, Ohio

Client: Bmp Apartments Llc

Permit #: FRDM1234561

1904 Lake Club Dr, Columbus, OH 43232

Date: Oct 24, 2012

Permit type: Kitchen Remodeling

Description: 1904 lake club dr plan approval: final. conditions of the plan approval: none. plan approval exclusions: none. reviewed for compliance under: 2011 obc and icc/ansi a117.1-2009. use / occupancy group: mortuary & funeral parlor / group b. construction type: iii-b description of the work: remodel former restaurant for new use as mortuary & funeral parlor. work includes removal or partitions, new partition, fill in wall openings with decorative and clear glass panels, new sink, lighting revisions, and power revisions. existing kitchen hood and makeup air unit is being modified to provide heating and ventilation for embalming room. hood is no longer type i. consequently, the existing rtu for embalming room is being disconnected. hood suppression is being removed. separate permits reqd for plmb, elec, mech & fire alarm. conditions, limitations, variances and special stipulations of the occupancy: none. design occupant load: 216 [r.b. 1/8/13]. maximum capacity card: issued. numbers: 12-98a, 12-98b. fire suppression systems: sprinkler system is not required because, in accordance with obc 903.2.1.3, exception 2, the fire area has no fixed seating and is not used for exhibition or display. fire alarm system: [not required because occupant load is less than 300. -r.b. 1/8/13] storage: not applicable record / history: verified former restaurant (a3) and construction type (iii-b). .

Valuation: $5,000,000

Client: Smith Mortuary/Vida Lindsey

Permit #: CHAN1235141

All data is collected from public records. We do not guarantee accuracy of information.