243 Cumming St, Savannah, GA 31415
Date: Apr 8, 2015
Permit type: Hvac
Description: Plumbing with electrical, sheetrock repair, floor joint, window and framing (put house back to original state no design changes. stop leak in roof.) plumbing fixtures are required to be installed in accordance with ipc2012 sec. 405.3.1. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. additional plans, details, and /or professional engineering may be required per inspectors discretion.
Valuation: $1,000,000
Client: Linda Kapers
Parcel #: 2-0019 -18-018
Permit #: 15-02996-MR
610 East Duffy Ln, Savannah, GA 31401
Date: Apr 9, 2015
Permit type: Hvac
Description: Update electrical, hvac, plumbing, and windows. add 1 hr firewall to common area. new flooring, cabinets. will need temp power pole. smoke/carbon monoxide detectors are required to be installed in accordance with irc 314.3.1 and irc 315.3 prior to issuance of any certificate of completion/occupancy. smoke detector is required in each sleeping room, outside each sleeping area in the immediate vicinity of the bedrooms and each story. carbon monoxide detector is required outside of sleeping area in the immediate vicinity of bedrooms. additional plans, details, and /or professional engineering may be required per inspectors discretion. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. plumbing fixtures are required to be installed in accordance with ipc2012 sec. 405.3.1. mechanical work to be designed and installed per irc 2012 mechanical code section requirements.
Valuation: $1,800,000
Client: Carrie A Crow
Parcel #: 2-0054 -06-024
Permit #: 15-00022-MR
610 East Duffy Ln, Savannah, GA 31401
Date: Apr 9, 2015
Permit type: Hvac
Description: Update electrical, hvac, plumbing, and windows. add 1 hr firewall to common area. new flooring, cabinets. will need temp power pole. smoke/carbon monoxide detectors are required to be installed in accordance with irc 314.3.1 and irc 315.3 prior to issuance of any certificate of completion/occupancy. smoke detector is required in each sleeping room, outside each sleeping area in the immediate vicinity of the bedrooms and each story. carbon monoxide detector is required outside of sleeping area in the immediate vicinity of bedrooms. additional plans, details, and /or professional engineering may be required per inspectors discretion. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. plumbing fixtures are required to be installed in accordance with ipc2012 sec. 405.3.1. mechanical work to be designed and installed per irc 2012 mechanical code section requirements.
Valuation: $800,000
Client: Carrie A Crow
Permit #: 15-01186-MR
95 Winslow Cir Lot 156, Savannah, GA 31322
Date: Apr 9, 2015
Permit type: Hvac
Description: Construction of a two story, single family home with four bedrooms and three baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2. 1.7 ton btu load
Valuation: $35,664,000
Client: Mungo Homes Of Georgia Llc
Parcel #: 2-1016E-03-030
Permit #: 15-01007-MR
104 Cockle Shell Rd Lot 91, Savannah, GA 31419
Date: Apr 10, 2015
Permit type: Hvac
Description: Construction of a two story, single family home, "mountain", elevation b, four bedrooms and two and a half baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.
Valuation: $19,700,000
Client: Wade Seyle
Parcel #: 2-1003 -01-102
Permit #: 15-02932-MR
116 Cockle Shell Rd Lot 85, Savannah, GA 31419
Date: Apr 10, 2015
Permit type: Hvac
Description: Construction of a two story, single family home, "mountain", elevation b, four bedrooms and two and a half baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.
Valuation: $20,300,000
Client: Wade Seyle
Parcel #: 2-1003 -01-096
Permit #: 15-02922-MR
34 Fiore Dr Lot 218, Savannah, GA 31419
Contractor: Byrd Heating & Air Conditioning
Date: Apr 10, 2015
Permit type: Hvac
Description: Construction of a two story, single family residence with four bedrooms and two and a half baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2. 1.51 tons ac
Valuation: $11,800,000
Client: Robert & Richard Flanders
Parcel #: 2-1030G-06-020
Permit #: 15-01747-MR
6700 Waters Ave, Savannah, GA 31406
Contractor: Byrd Heating & Air Conditioning
Date: Apr 10, 2015
Permit type: Hvac
Description: Replace unit
Valuation: $3,400,000
Fee: $277.00 paid to City of Savannah, Georgia
Client: Benny Curl
Parcel #: 2-0154 -04-020
Permit #: 15-03068-MC
24 West Harris St, Savannah, GA 31401
Contractor: All Seasons Comfort, Inc
Date: Apr 15, 2015
Permit type: Hvac
Description: Change out 2 ton heat pump
Valuation: $700,000
Fee: $61.00 paid to City of Savannah, Georgia
Client: Rhangos Bromstad
Parcel #: 2-0015 -35-011
Permit #: 15-03241-MR
5737 Colonial Dr, Savannah, GA 31406
Contractor: All Seasons Comfort, Inc
Date: Apr 17, 2015
Permit type: Hvac
Description: Change out condenser
Valuation: $150,000
Fee: $45.00 paid to City of Savannah, Georgia
Client: Richard Morgan
Parcel #: 2-0134 -03-001
Permit #: 15-03318-MR
1603 Cloverdale Dr, Savannah, GA 31415
Contractor: Climatech Air, Inc.
Date: Apr 17, 2015
Permit type: Hvac
Description: Heat pump system
Valuation: $400,000
Fee: $45.00 paid to City of Savannah, Georgia
Client: Alvin Edwards
Parcel #: 2-0069 -11-002
Permit #: 15-03291-MR
1801 Tubman St, Savannah, GA 31405
Contractor: Climatech Air, Inc.
Date: Apr 17, 2015
Permit type: Hvac
Description: A/c and coil
Valuation: $350,000
Fee: $45.00 paid to City of Savannah, Georgia
Client: Carlos Colon
Parcel #: 2-0704 -04-001
Permit #: 15-03292-MR
704 East 40Th St, Savannah, GA 31401
Contractor: Climatech Air, Inc.
Date: Apr 20, 2015
Permit type: Hvac
Description: Room addition and misc interior renovations to include mechanical, electrical and plumbing.
Valuation: $6,850,000
Client: Madeline Collins
Parcel #: 2-0063 -28-023
Permit #: 14-08593-MR
55 Concordia Dr Lot 512, Savannah, GA 31419
Contractor: Byrd Heating & Air Conditioning
Date: Apr 20, 2015
Permit type: Hvac
Description: Construction of a two story, single family home of plan 2956, with four bedrooms and two and a half baths on lot 512 bradley point south. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.
Valuation: $27,400,000
Client: Regal Builders
Parcel #: 2-1030F-09-029
Permit #: 15-01058-MR
1851 Cokesbury Dr, Savannah, GA 31406
Contractor: Byrd Heating & Air Conditioning
Date: Apr 20, 2015
Permit type: Hvac
Description: Replace existing system with carrier 3 ton 14 seer heat pump system
Valuation: $666,000
Fee: $61.00 paid to City of Savannah, Georgia
Client: Thomas E Mahany Iii
Parcel #: 2-0135 -03-007
Permit #: 15-03000-MC
19 Parkwood Dr, Savannah, GA 31404
Contractor: Canady's Precision Air Conditioning And Heating
Date: Apr 20, 2015
Permit type: Hvac
Description: Change out 2.5 ton heat pump
Valuation: $400,000
Fee: $45.00 paid to City of Savannah, Georgia
Client: Pamela Carswell
Parcel #: 2-0118 -07-021
Permit #: 15-03349-MR
1818 Upson St, Savannah, GA 31405
Contractor: Polar Air Inc
Date: Apr 20, 2015
Permit type: Hvac
Description: Address on application is 1818 upson street, pin 2-0704 -05-019. new construction single family residence with three bedrooms and two baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.
Valuation: $6,000,000
Client: Caesar & Essie M Cuspert
Parcel #: 2-0704 -05-019
Permit #: 15-00029-MR
239 Jimmy Deloach Pkwy, Savannah, GA 31407
Contractor: Kern & Co., Llc
Date: Apr 21, 2015
Permit type: Hvac
Description: Unit heater installation in existing warehouse.** flood zone: unnumbered a. have elev. cert. on file 15.2 navd 1988.
Valuation: $20,000,000
Client: Savannah Economic Development Authority
Parcel #: 2-0981 -01-012
Permit #: 15-03336-MC
302 Megan Ct, Savannah, GA 31405
Contractor: Kern & Co., Llc
Date: Apr 21, 2015
Permit type: Hvac
Description: Install new condneser and coil
Valuation: $380,000
Fee: $45.00 paid to City of Savannah, Georgia
Client: Louis Freedman
Parcel #: 2-0145 -01-011
Permit #: 15-03385-MR
51 Telford St Lot 5, Savannah, GA 31322
Contractor: Mcdevitt Air
Date: Apr 22, 2015
Permit type: Hvac
Description: New construction of a two story single family home with five bedrooms and three and a half baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.
Valuation: $37,500,000
Client: Lamar Smith Signature Home
Parcel #: 2-1016H-01-027
Permit #: 15-01833-MR