4612 Savannah Ave, McAllen, TX 78503
Date: Apr 20, 2011
Permit type: Commercial Contracting
Description: Sidewalks a) sidewalk alignment must match existing alignment in area or be set a minimum of five-foot from the back of curb. any deviation shall require approval by the city engineer. b) sidewalk shall slope toward the street with a maximum transverse slope of inch per foot (2%), 1-inch above the top of curb, and a maximum longitudinal slope of inch per foot (5%). c) sidewalk shall be 4-foot minimum width when placed at an offset behind the curb, and 5-foot minimum width when placed adjacent to the curb. d) sidewalks and ramps shall be constructed of 4 thick concrete reinforced with 6 x 6 no. 6 gage wire mesh or no. 3 bars @ 8 o.c.e.w. e) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness f) sand backfill required on all sidewalks 3 max. sub-grade shall be compacted to 90% standard proctor. g) contraction joints shall be scored every 6 feet and expansion joints every 30 feet. h) sidewalk shall have a broom finish transverse to the walkway. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) ramps shall be placed at all intersection with roadways or where required by law. curb and gutter must be saw cut. l) flatwork is required to meet texas accessibility standards (texas civil statutes, article 9102). any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. additionally, decorative concrete shall require approval of the pattern and finish from the city engineer, or designee, prior to construction. residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Jesus H & Norma A Ruiz
Parcel #: L202000000004800
Permit #: ROW2011-02434
7312 N 22Nd St, McAllen, TX 78504
Date: Apr 20, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Lee A & Laura Vasquez
Parcel #: W736005000017200
Permit #: ROW2011-02426
3416 Oriole Ave, McAllen, TX 78504
Date: Apr 21, 2011
Permit type: Commercial Contracting
Description: Do not build inside site set backs or utility easements. please call city of mcallen eng. dept for inspection @ 956-681-1150
Client: Carmen M Arizmendi
Parcel #: S402002000006000
Permit #: ROW2011-02443
6501 N 35Th St, McAllen, TX 78504
Date: Apr 25, 2011
Permit type: Commercial Contracting
Description: Residential storage note: as per customer he will be applying for variance since storage has been built for over a year and he cannot move it to meet setbacks. he is applying for enclosure of a garage for bedrooms seperately that work has not been done (eek)
Valuation: $300,000
Client: David & Adelita B Briales
Parcel #: S402001000004100
Permit #: RES2011-02491
5032 Heron Ave, McAllen, TX 78504
Date: Apr 25, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Affordable Homes Of South Texas
Parcel #: T101400000013700
Permit #: ROW2011-02468
904 E Upas Ave, McAllen, TX 78501
Date: Apr 26, 2011
Permit type: Commercial Contracting
Description: New apartments (fourplex) type vb construction, group r-2, fire sprinkler system required. no blueprint revised engineered plan 8/4/11 (jerry/eek) pmt renewal no changes 1/25/13 (eek) 2nd pmt renewal no changes 2/26/14 (eek)
Valuation: $13,639,600
Fee: $3,392.14 paid to City of Mcallen, Texas
Client: Ramali Inc
Parcel #: R052003000000800
Permit #: CMM2011-02550
421 Cottonwood Ave, McAllen, TX 78501
Date: Apr 27, 2011
Permit type: Commercial Contracting
Description: Sidewalks a) sidewalk alignment must match existing alignment in area or be set a minimum of five-foot from the back of curb. any deviation shall require approval by the city engineer. b) sidewalk shall slope toward the street with a maximum transverse slope of inch per foot (2%), 1-inch above the top of curb, and a maximum longitudinal slope of inch per foot (5%). c) sidewalk shall be 4-foot minimum width when placed at an offset behind the curb, and 5-foot minimum width when placed adjacent to the curb. d) sidewalks and ramps shall be constructed of 4 thick concrete reinforced with 6 x 6 no. 6 gage wire mesh or no. 3 bars @ 8 o.c.e.w. e) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness f) sand backfill required on all sidewalks 3 max. sub-grade shall be compacted to 90% standard proctor. g) contraction joints shall be scored every 6 feet and expansion joints every 30 feet. h) sidewalk shall have a broom finish transverse to the walkway. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) ramps shall be placed at all intersection with roadways or where required by law. curb and gutter must be saw cut. l) flatwork is required to meet texas accessibility standards (texas civil statutes, article 9102). any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. additionally, decorative concrete shall require approval of the pattern and finish from the city engineer, or designee, prior to construction. residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Titus Development Ltd
Parcel #: B184500000003100
Permit #: ROW2011-02577
700 Dallas Ave, McAllen, TX 78501
Date: Apr 29, 2011
Permit type: Commercial Contracting
Description: Service re-do, irrigation system/ meter to be turned to face street as requested by aep esi #100-37677460
Client: City Of Mcallen
Parcel #: H255000008000308
Permit #: CMM2011-02625
3217 Fuerte Ave, McAllen, TX 78504
Date: May 2, 2011
Permit type: Commercial Contracting
Description: Sidewalks a) sidewalk alignment must match existing alignment in area or be set a minimum of five-foot from the back of curb. any deviation shall require approval by the city engineer. b) sidewalk shall slope toward the street with a maximum transverse slope of inch per foot (2%), 1-inch above the top of curb, and a maximum longitudinal slope of inch per foot (5%). c) sidewalk shall be 4-foot minimum width when placed at an offset behind the curb, and 5-foot minimum width when placed adjacent to the curb. d) sidewalks and ramps shall be constructed of 4 thick concrete reinforced with 6 x 6 no. 6 gage wire mesh or no. 3 bars @ 8 o.c.e.w. e) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness f) sand backfill required on all sidewalks 3 max. sub-grade shall be compacted to 90% standard proctor. g) contraction joints shall be scored every 6 feet and expansion joints every 30 feet. h) sidewalk shall have a broom finish transverse to the walkway. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) ramps shall be placed at all intersection with roadways or where required by law. curb and gutter must be saw cut. l) flatwork is required to meet texas accessibility standards (texas civil statutes, article 9102). any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. additionally, decorative concrete shall require approval of the pattern and finish from the city engineer, or designee, prior to construction. residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Affordable Homes Of South Texas In
Parcel #: T736501000008500
Permit #: ROW2011-02684
920 N 15Th St, McAllen, TX 78501
Date: May 2, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Raquel M Cavazos
Parcel #: E840000017000800
Permit #: ROW2011-02647
6704 N 7Th Ct, Apt B, McAllen, TX 78504
Date: May 4, 2011
Permit type: Commercial Contracting
Description: Apartment repair vehicle ran into wall (replacement of damaged studs, exterior brick veneer, replace damaged electrical wire) type vb construction, group r-2, no fire sprinker system no blueprint
Valuation: $1,000,000
Fee: $57.50 paid to City of Mcallen, Texas
Client: Daymon Monday
Parcel #: R337000000002700
Permit #: CMM2011-02772
4712 Military Hwy, McAllen, TX 78503
Date: May 5, 2011
Permit type: Commercial Contracting
Description: Twc contractor will be placing a new cable on the northside ot military hwy (fm 1016 ) beginning at international blvd and going west for 4000 ft.
Client: Commercial Net Lease Realty Lp
Parcel #: S300400000000100
Permit #: ROW2011-02784
3607 S L Ln, McAllen, TX 78503
Date: May 5, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Bella Ragazza Llc
Parcel #: L315100000003900
Permit #: ROW2011-02813
1212 E Pineridge Ave, McAllen, TX 78503
Contractor: Archie's Electric Inc.
Date: May 6, 2011
Permit type: Commercial Contracting
Description: New condo 4plex type vb construction, group r-2, fire sprinkler system required no blueprints
Fee: $245.00 paid to City of Mcallen, Texas
Client: O C Development Ltd
Parcel #: L314900002001300
Permit #: CMM2011-02855
2033 Industrial Dr, McAllen, TX 78504
Contractor: Julio C Rangel Electrical Works
Date: May 10, 2011
Permit type: Commercial Contracting
Description: Childdaycare to office remodel (remove wall, move cabinets, delete some and electrical and add some electrical, add garage door, flooring) no blueprint
Fee: $54.00 paid to City of Mcallen, Texas
Client: 2101 Industrial Dr
Parcel #: M217000000000700
Permit #: CMM2011-02910
9018 N 22Nd Ln, McAllen, TX 78504
Date: May 11, 2011
Permit type: Commercial Contracting
Description: Sidewalks a) sidewalk alignment must match existing alignment in area or be set a minimum of five-foot from the back of curb. any deviation shall require approval by the city engineer. b) sidewalk shall slope toward the street with a maximum transverse slope of inch per foot (2%), 1-inch above the top of curb, and a maximum longitudinal slope of inch per foot (5%). c) sidewalk shall be 4-foot minimum width when placed at an offset behind the curb, and 5-foot minimum width when placed adjacent to the curb. d) sidewalks and ramps shall be constructed of 4 thick concrete reinforced with 6 x 6 no. 6 gage wire mesh or no. 3 bars @ 8 o.c.e.w. e) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness f) sand backfill required on all sidewalks 3 max. sub-grade shall be compacted to 90% standard proctor. g) contraction joints shall be scored every 6 feet and expansion joints every 30 feet. h) sidewalk shall have a broom finish transverse to the walkway. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) ramps shall be placed at all intersection with roadways or where required by law. curb and gutter must be saw cut. l) flatwork is required to meet texas accessibility standards (texas civil statutes, article 9102). any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. additionally, decorative concrete shall require approval of the pattern and finish from the city engineer, or designee, prior to construction. residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. g) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. (h) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. i) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. j) sub-grade shall be compacted to 90% standard proctor. k) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. l) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. m) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. n) driveway wings shall not exceed a 12:1 slope. o) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: James M Moffitt
Parcel #: N484702000005100
Permit #: ROW2011-02934
905 Dove Ave, McAllen, TX 78577
Contractor: Marios Electric
Date: May 11, 2011
Permit type: Commercial Contracting
Description: Water heater/ disconnect ok by bt/mm
Fee: $15.00 paid to City of Mcallen, Texas
Client: John P Abraham
Parcel #: B437000000000700
Permit #: CMM2011-02967
313 E Vine Ave, McAllen, TX 78501
Date: May 12, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) no colored or stained concrete on city driveway apron g) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. h) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) sub-grade shall be compacted to 90% standard proctor. l) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. m) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. n) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. o) driveway wings shall not exceed a 12:1 slope. p) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. q)requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Oscar E & Blanca Gonzalez
Parcel #: M260002000003300
Permit #: ROW2011-02999
3313 Daytona Ave, McAllen, TX 78503
Date: May 16, 2011
Permit type: Commercial Contracting
Description: Residential driveway apron (a) minimum driveway width allowed is 12 ft. and maximum is 25 ft. b) curb cut must be a minimum of 6-feet from a side property line. c) flow line of new gutter shall match existing flow line. d) curb and gutter must be saw cut. e) driveway aprons shall be constructed of concrete with a minimum of 6 inches in thickness, reinforced with 6 x 6 no. 6 wire mesh, no. 3 bars @ 12 o.c.e.w. or no. 4 bars @ 18 o.c.e.w. f) no colored or stained or stamped concrete on city driveway apron g) bar-lift plastic chairs, or approved equal, shall be used to secure steel at center of concrete thickness. h) concrete shall have a broom finish. exposed aggregate, pavers, tile and stained or painted concrete are not permitted within the right of way. i) all concrete shall be 5-sack concrete and shall have a minimum compressive strength of 3000 psi. j) membrane curing compound shall be applied at a minimum of 1 gallon per 180 square feet of area. k) sub-grade shall be compacted to 90% standard proctor. l) expansion joint required at property line and intersection with sidewalks. longitudinal expansion joint required at mid-point of driveway if width is greater than 18 feet. m) if a manhole falls within a driveway pad, the manhole lid shall be placed flush with the elevation of the driveway. n) any driveway placed where a drainage bar ditch exists, shall maintain the flow line of the ditch with the placement of a concrete culvert. o) driveway wings shall not exceed a 12:1 slope. p) respect the transverse slope of 2% maximum where the sidewalk crossing is proposed. any admixtures to the concrete mix (i.e. fiber mesh, plasticizers, etc.) shall require approval. q) requirements of plat note slope of 1%. in no instance shall site grading on residential or commercial properties adversely affect neighboring properties.
Client: Liborio & Odilia S Martinez
Parcel #: B030000027001100
Permit #: ROW2011-03085
6704 N 7Th Ct, Apt B, McAllen, TX 78504
Contractor: Davids Electric
Date: May 17, 2011
Permit type: Commercial Contracting
Description: Apartment repair vehicle ran into wall (replacement of damaged studs, exterior brick veneer, replace damaged electrical wire) type vb construction, group r-2, no fire sprinker system no blueprint
Fee: $59.00 paid to City of Mcallen, Texas
Client: Daymon Monday
Parcel #: R337000000002700
Permit #: CMM2011-03089