Contractors DirectoryInformation on every contractor in United States

Commercial Contracting Permits in Baltimore, MD

101 N Haven St, Baltimore, MD 21224

Date: Aug 12, 2013

Permit type: Commercial Contracting

Description: Install 3 low voltage fire alarms as per code.

Permit #: COM2013-16673

830 W 40Th St, Baltimore, MD 21211

Date: Aug 13, 2013

Permit type: Commercial Contracting

Description: Annual maintenance work (2,000 amp) 480 volt service as per code.

Permit #: COM2013-16779

3615 Falls Road, Baltimore, MD 21211

Date: Aug 13, 2013

Permit type: Commercial Contracting

Description: (use)continue to use the premises for a private elementary school on to 2nd fl and 1st fl daycare for up to 70 children ages 2yrs to elementary age business hours from mon-friday from 7:30am-5:30pm with upto 5 employees. property has 6 off street parking spaces. with food served to daycare children only, warmed only.

Permit #: USE2013-02912

830 W 40Th St, Baltimore, MD 21211

Date: Aug 13, 2013

Permit type: Commercial Contracting

Description: Install 66 addressable smoke detectors and wiring for same in health care facility (total of 66). as per plans as per code

Permit #: COM2013-10898

6713 Westbrook Road, Baltimore, MD 21215

Date: Aug 13, 2013

Permit type: Commercial Contracting

Description: 12 recess lts, 4 sconce lts, 4 coach lts, 8 receptacles, 5 switches. install 60 ampere sub panel 16 ckt - 4 ckts & 33 fixtures and devices as per code.

Permit #: COM2013-16758

915 S Wolfe St, Baltimore, MD 21231

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: Exterior work - non-structural alterations - install one non-illuminated blade sign "p" 6.75 sq ft of aluminum and white acrylic, mounted with lag, shield bolts 2'3"x3' as per sketch & as per code. per commercial - awc - must have chap approval * notice to proceed 8 install one non-illuminated blade sign "p" of aluminum and white acrylic, 6.5 square feet, mounted with lag shield bolts. sign measures 2'6" x 3' and will be 10' from grade to bottom of the sign.

Permit #: COM2013-07574

6611 Cabot Dr, Baltimore, MD 21226

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: New tenant fit-out in ex warehouse * rpl 3-ex duct smoke detectors when a/c replaced * 100a sub panel * 2-sign ckts only

Fee: $150.00 paid to Anne Arundel County

Client: Amb Cabot Llc

Parcel #: 3536-9007-3104

Permit #: E02271563

1415 Riverside Ave, Baltimore, MD 21230

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: Dismantle existing 3-story formstone front facade, clean, grind out existing mortar joints and repoint all brick as per code.

Permit #: COM2013-16909

115 Franklin Ave, Baltimore, MD 21225

Contractor: Donlee Electric Inc

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: Replace to an existing space replacing an existing federal pacific panel with n ew.

Fee: $110.00 paid to Anne Arundel County

Client: Campbell Kevin V

Parcel #: 5046-1817-9500

Permit #: E02271532

915 S Wolfe St, Baltimore, MD 21231

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: Exterior work - non-structural alterations - install one illuminated blade sign 21.6 sq ft of aluminum and white acrylic and mounted with laq. shield, bolts "p, union wharf. red star dead end union box company, tbc & studio" with arrow (2'6"x8'8") as per sketch & as per code. per commercial awc - must have chap approval * notice to proceed * install one exterior-illuminated blade sign aluminum and white acrylic, 21.6 square feet, mounted with lag shield bolts. sign measures 2'6" x 8' and will be 10' from grade to bottom of the sign.

Permit #: COM2013-07575

3799 Boston St, Baltimore, MD 21224

Date: Aug 14, 2013

Permit type: Commercial Contracting

Description: Install 2000 amp exterior switch gear. install generator docking station. install 3-4in pvc conduits from docking station to switch gear. install 6-4in pvc conduits from secondary side of existing transformer. all as per plans and as per code.

Permit #: COM2013-11605

5923 The Alameda, Baltimore, MD 21239

Date: Aug 15, 2013

Permit type: Commercial Contracting

Description: Replace all fixtures and devices (46) install (6) new circuits. install interconnected smoke detectors as per code. update grounds as per code.

Permit #: COM2013-17160

4508 Fairfax Road, Baltimore, MD 21216

Date: Aug 15, 2013

Permit type: Commercial Contracting

Description: Amend permit# com2013-14295 issued on 07/11/13 to add the following additional work: add additional meter for 60 amp public panel as per code original permit description:(com2013-14295) upgrade service to 2- 60 amps panels, 1 for each floor, all work as per code. wire for sum pump outlet. total service 120 amps asper code.

Permit #: COM2013-17144

5001 Palmer Ave, Baltimore, MD 21215

Date: Aug 15, 2013

Permit type: Commercial Contracting

Description: Interior work (480 sq ft) - non-structural alterations - category i - install drain tile on all 4 basement walls toatl of 92 linear feet. remove concrete 12" wide 10" deep and #57 stone base, 3" drain tile & cover with #57 stone & plastic & 4" thick concrete. include sump pit & pump & discharge pipe. skim coat full floor as per code. * no curbing or underpinning

Permit #: COM2013-17152

940 Madison Ave, Baltimore, MD 21201

Date: Aug 15, 2013

Permit type: Commercial Contracting

Description: Installing temporary lights & receptacles as per code

Permit #: COM2013-17283

2827 Clearview Ave, Baltimore, MD 21234

Date: Aug 16, 2013

Permit type: Commercial Contracting

Description: Amend permit com2013-11839 issued on 06/1013 to add the following additional work: install a 100 amp service as per code original permit description:(com2013-11839) install a 30amp 120volt service. install a 30amp 120volt service for the existing electric meter. as per code.

Permit #: COM2013-17336

120 Mcmechen St, Baltimore, MD 21217

Date: Aug 16, 2013

Permit type: Commercial Contracting

Description: (use) use portion of premises k/a 130 mcmechen st as a 5- story 62 dwelling unit detacthed dormitory building- per bmza 2012-196 approved 6/12/2012 bolton hill hist/arch pres distr mica, mria and the fire department will confer about the placement of the generator, fence and bollard, as the fire department has the expertise in this area.

Permit #: USE2013-03009

650 S Exeter St, Baltimore, MD 21202

Date: Aug 16, 2013

Permit type: Commercial Contracting

Description: Use the 10th floor as offices for financial services

Permit #: USE2013-02887

2525 E Kirk Ave, Baltimore, MD 21218

Date: Aug 16, 2013

Permit type: Commercial Contracting

Description: Install fire alarm 1 panel and 276 devices as per plans as per code

Permit #: COM2013-12678

3815 Towanda Ave, Baltimore, MD 21215

Date: Aug 16, 2013

Permit type: Commercial Contracting

Description: 15 ckts and 4 low voltage (cable) work done to code.

Permit #: COM2013-17371