Contractors DirectoryInformation on every contractor in United States

Tilley Fire Equipment Company Joseph C Stough

280 N. Broad Street, Doylestown, PA 18901


Contact Information


HIC #:
45003
Status:
Active
City:
Philadelphia
Type:
Fire Suppression System

Verified:
Status:Verify
Date:August, 2015
Source:City of Philadelphia Licensed Contractors

Tilley Fire Equipment Company Joseph C Stough Additional Information Add Info

No additional information for Tilley Fire Equipment Company Joseph C Stough yet.

Reviews Write Review

No reviews for Tilley Fire Equipment Company Joseph C Stough yet.

Permits (18)

561 Fairthorne Ave, Philadelphia, PA 19128

Date: Apr 25, 2013

Permit type: Plumbing

Description: Add sprinklers heads and piping to existing nfpa 13 fire suppression system in closets of gym as per plans.

Permit #: 461771

9801 Blue Grass Rd, Philadelphia, PA 19114

Date: Mar 21, 2013

Permit type: Plumbing

Description: Replace piping for nfpa 13 fir supprssion system on loading dock-warehouse as per plans.

Permit #: 454530

600 W Cheltenham Ave, Philadelphia, PA 19126

Date: Aug 8, 2012

Permit type: Plumbing

Description: Add 2 sprinkler heads in existing elevator shaft to comply with doh & ls 101. connect to existing system/piping

Permit #: 414938

222 High St, Philadelphia, PA 19144

Date: Jun 6, 2011

Permit type: Hvac

Description: Replace existing ansul suppression system kitchen hood, correct issued violation 272914 for failed certification of hood suppression.

Permit #: 336993

561 Fairthorne Ave, Philadelphia, PA 19128

Date: Sep 22, 2010

Permit type: Plumbing

Description: Install a double check backflow preventer

Permit #: 287919

600 W Cheltenham Ave, Philadelphia, PA 19126

Date: May 21, 2010

Permit type: Plumbing

Description: Relocate 3 sprinkler heads - 3rd floor atrium

Permit #: 280647

9801 Blue Grass Rd, Philadelphia, PA 19114

Date: Dec 14, 2009

Permit type: Plumbing

Description: Alterations to existing ansul fire suppression system.

Permit #: 248212

8015 Lawndale Ave, Philadelphia, PA 19111

Date: Jan 26, 2009

Permit type: Plumbing

Description: Add sprinklers to existing dry system to provide coverage above and below ceiling in new addition as per plans.

Permit #: 193513

913 E Cliveden St, Philadelphia, PA 19119

Date: Dec 9, 2008

Permit type: Plumbing

Description: Relocate 2 sprinkler heads.

Permit #: 191854

7107 Old York Rd, Philadelphia, PA 19126

Date: Sep 11, 2008

Permit type: Plumbing

Description: Relocate 6 sprinkler heads on 1st floor dining room

Permit #: 176762

920 Red Lion Rd, Philadelphia, PA 19115

Date: Aug 14, 2008

Permit type: Plumbing

Description: Relocate 59 sprinkler heads throughout store (acme)

Permit #: 171263

600 W Cheltenham Ave, Philadelphia, PA 19126

Date: May 13, 2008

Permit type: Plumbing

Description: Relocate 20 sprinkler heads, 1st floor nursing & rehab center

Permit #: 151694

7107 Old York Rd, Philadelphia, PA 19126

Date: Dec 27, 2007

Permit type: Plumbing

Description: Install (1) sprinkler on second flr.

Permit #: 117949

7107 Old York Rd, Philadelphia, PA 19126

Date: Jul 27, 2007

Permit type: Plumbing

Description: Relocate 5 sprinkler heads.

Permit #: 92367

600 W Cheltenham Ave, Philadelphia, PA 19126

Date: Jul 25, 2007

Permit type: Plumbing

Description: Relocate 5 sprinkler heads.

Permit #: 91910

3345 W Hunting Park Ave, Philadelphia, PA 19132

Date: Jul 9, 2007

Permit type: Plumbing

Description: Renovation on sprinkler system on lower level to comply with nfpa #13.

Permit #: 85115

7107 Old York Rd, Philadelphia, PA 19126

Date: Jun 22, 2007

Permit type: Remodeling

Description: Add (2) sprinklers over o2 storage on loading area per pa dept. of health

Permit #: 78587

913 E Cliveden St, Philadelphia, PA 19119

Date: Jun 13, 2007

Permit type: Plumbing

Description: Relocate 4 sprinkler heads (basement - nursing home)

Permit #: 82681