Contractors DirectoryInformation on every contractor in United States

Adorante Electric Inc

430 Thornton Rd, Cheyney, PA 19319


Contact Information

Phone:
(610) 299-8374
Service:
Electrical, Commercial Contracting
Employees:
Michael A. Adorante (President/Owner)

HIC #:
PA021878
Status:
Active
Type:
Electrical Contractor Providing All Electrical Services Residential And Commercial

Verified:
Status:Verify
Date:August, 2015
Source:Pennsylvania Office of the Attorney General
Insurer:
Cumberland Mutual Fire Insurance Co

Adorante Electric Inc Additional Information Add Info

No additional information for Adorante Electric Inc yet.

Reviews Write Review

No reviews for Adorante Electric Inc yet.

Permits (11)

762 S 18Th St, Philadelphia, PA 19146

Date: Apr 10, 2015

Permit type: Electrical

Description: Replace 2 lights with 6 recess lights per 2008 nec (sfd)

Permit #: 601904

4066 Kensington Ave, Philadelphia, PA 19124

Date: Feb 9, 2015

Permit type: Commercial Contracting

Description: Install 120v outdoor ckt to 12vdc trickle charger to comply w/110 (3) (b) as per nec 2008 also chapter 9-3800 newly enacted bill 120328 & iec standard 60335-2-76 (comm)

Permit #: 589410

924 S 11Th St, Philadelphia, PA 19147

Date: Nov 14, 2013

Permit type: Commercial Contracting

Description: F&i new electrical & f/a, sesign drawings e.o through e5 all new devices wiring, hardware and all new components as per nec 2008 & nfpa 72

Permit #: 504235

4923 Merion Ave, Philadelphia, PA 19131

Date: Sep 23, 2013

Permit type: Electrical

Description: Electrical alterations (storage yard) - install a 120v outdoor circuit to a 12vdc trickle charger to comply with 110(3)(b)of the 2008 nec, also chapter 9-3800 of the newly enacted bill 120328 and iec standard 60335-2-76

Permit #: 496325

6601 New State Rd, Philadelphia, PA 19135

Date: Aug 13, 2013

Permit type: Commercial Contracting

Description: Install 120v outdoor circuit 12vdc trickle charger to comply w/110 (3)b of nec,also chapter 9-3800 of newly enacted bill 120328, and iec standard 60335-2-76 (auto storage yard)

Permit #: 488838

5135 Bleigh Ave, Philadelphia, PA 19136

Date: Feb 28, 2013

Permit type: Commercial Contracting

Description: Installation of circuit to supply 12v trickle charge, installation is to comply w/article 110(3)(b) of 2008 nec installation is per code 9-3800 of newly enacted bill 120328 (only)

Permit #: 456197

5135 Bleigh Ave, Philadelphia, PA 19136

Date: Feb 28, 2013

Permit type: Electrical

Description: Erection of a 10'-0" high perimeter security fence. separate electrical permit required.

Permit #: 445386

5135 Bleigh Ave, Philadelphia, PA 19136

Date: Oct 28, 2011

Permit type: Commercial Contracting

Description: 10'high, low voltage(12v) battery powered, perimeter burgular alarm security system,located 10' inside of existing 8' high perimeter fence 2008 nec (east district)

Permit #: 364421

910 N 64Th St, Philadelphia, PA 19151

Date: Mar 30, 2010

Permit type: Electrical

Description: Rewire house using existing service as per nec (west dist)

Permit #: 269548

4367 Pechin St, Philadelphia, PA 19128

Date: Dec 9, 2009

Permit type: Bathroom Remodeling

Description: Re wire 3rd floor and 2nd floor kitchen and bathroom as per 2005 nec (north district)

Permit #: 248146

205 Sumac St, Philadelphia, PA 19128

Date: Jul 31, 2008

Permit type: Electrical

Description: Install 200a panel, proper grounding & rewire sfd as per 2005 nec.

Permit #: 168289

Adorante Electric Inc - Similar Contractors