Contractors DirectoryInformation on every contractor in United States

Lamar Smith Signature Homes Llc

103 Williams Avenue, Reidsville, GA 30453

Service:
Home Builders

License:
Georgia #RLCO002603
Status:
Active
Type:
Residential/General Contractor

License:
Georgia #RLCO002706
Status:
Active
Type:
Residential Light Company, Residential/General Contractor

License:
Georgia #RLCO002947
Status:
Active
Type:
Residential Light Company

License:
Georgia #RLCO003310
Status:
Active
Type:
Residential Light Company

Verified:
Status:Not verified

Lamar Smith Signature Homes Llc Additional Information Add Info

No additional information for Lamar Smith Signature Homes Llc yet.

Reviews Write Review

No reviews for Lamar Smith Signature Homes Llc yet.

Permits (8)

109 Grimsby Rd Lot 206, Savannah, GA 31322

Sponsored by Rehold
Information About Property

Date: Mar 2, 2016

Permit type: New Construction

Description: Construction of a two story, single family home, five bedrooms, four and a half baths, elevation e, craftsman stone, front entry garage, 3rd car garage, bath 4 ilo master bedroom "his closet". smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.

Valuation: $32,698,000

Fee: $2,821.00 paid to City of Savannah, Georgia

Client: Kristan Creasy

Parcel #: 2-1016H-03-026

Permit #: 16-01317-BR

50 Teal Lake Dr Lot 71, Savannah, GA 31302

Sponsored by Rehold
Information About Property

Date: Dec 17, 2015

Permit type: New Construction

Description: Construction of a two story, single family home with attached three car garage, four bedrooms and three baths. s/d design fin. fl. of house at 15.3 navd 1988. *flood zone ae-11+1fb=12 navd88. outside air condenser and all electrical must be above 12'. flood resistant material, class 4 or 5 below 12'. must have hydrostatic vents in garage if garage's fin. fl below 11'. need verification that top of slab is at or above 15.3 navd88 just after slab is poured and need a loma for the structure and "finish construction" elev. cert. prior to releasing electricity or c.o. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.

Valuation: $30,204,000

Fee: $2,629.00 paid to City of Savannah, Georgia

Client: Lamar Smith Signature Home

Parcel #: 2-1029 -03-075

Permit #: 15-10248-BR

52 Teal Lake Dr Lot 72, Savannah, GA 31302

Sponsored by Rehold
Information About Property

Date: Dec 17, 2015

Permit type: New Construction

Description: Construction of a two story, single family home with attached two car garage, four bedrooms and three baths. s/d design fin. fl. of house to be at 15.3 navd 1988. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2. flood zone: property in ae and x, house in the x zone. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.

Valuation: $32,649,000

Fee: $2,821.00 paid to City of Savannah, Georgia

Client: Lamar Smith Signature Home

Parcel #: 2-1029 -03-076

Permit #: 15-10247-BR

54 Teal Lake Dr Lot 73, Savannah, GA 31302

Sponsored by Rehold
Information About Property

Date: Nov 30, 2015

Permit type: New Construction

Description: Construction of a two story, single family home with four bedrooms and three and a half baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2014 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc 2012 requirements. new glazing shall meet requirement of large missile test of astme 1996 and astme 1886 or provide wood structural panels for windborne debris protection in accordance to irc 301.2.1.2.

Valuation: $32,319,000

Fee: $2,797.00 paid to City of Savannah, Georgia

Client: Lamar Smith Signature Home

Parcel #: 2-1029 -03-077

Permit #: 15-10087-BR

9 Hopeland Ct Lot 15, Savannah, GA 31419

Sponsored by Rehold
Information About Property

Date: Sep 18, 2014

Permit type: Hvac

Description: New two story single family home with four bedrooms and three baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc/imc 2012 requirements.

Valuation: $28,848,000

Client: Lamar Smith Signature Homes

Parcel #: 2-0780 -02-073

Permit #: 14-06125-MR

9 Hopeland Ct Lot 15, Savannah, GA 31419

Date: Aug 6, 2014

Permit type: New Construction

Description: New two story single family home with four bedrooms and three baths. smoke/carbon monoxide detectors are required to be installed in accordance with irc2012 sec. r314.3.1 prior to issuance of any certificate of completion/occupancy. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc/imc 2012 requirements.

Valuation: $28,848,000

Fee: $2,312.00 paid to City of Savannah, Georgia

Client: Lamar Smith Signature Homes

Parcel #: 2-0780 -02-073

Permit #: 14-05495-BR

56 Hopeland Dr Lot 55, Savannah, GA 31419

Date: Jul 22, 2014

Permit type: Electrical

Description: Construction of a two story single family home with four bedrooms and three and a half baths. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc/imc 2012 requirements.

Valuation: $32,160,000

Client: Lamar Smith Signature Homes

Parcel #: 2-0780 -03-116

Permit #: 14-05278-ER

56 Hopeland Dr Lot 55, Savannah, GA 31419

Date: Jul 9, 2014

Permit type: New Construction

Description: Construction of a two story single family home with four bedrooms and three and a half baths. electrical work to be designed and installed per nec 2011 requirements. plumbing work to be designed and installed per ipc 2012 requirements. mechanical work to be designed and installed per irc/imc 2012 requirements.

Valuation: $32,160,000

Fee: $2,576.00 paid to City of Savannah, Georgia

Client: Lamar Smith Signature Homes

Parcel #: 2-0780 -03-116

Permit #: 14-04198-BR

All data is collected from public records. We do not guarantee accuracy of information.