Corna/Kokosing Construction Company
6235 Westerville Rd , Westerville, OH 43081
Contact Information
Corna/Kokosing Construction Company Additional Information Add Info
No additional information for Corna/Kokosing Construction Company yet.
Reviews Write Review
No reviews for Corna/Kokosing Construction Company yet.
Permits (4)
3900 Chagrin Dr, Columbus, OH 43219
Date: Jan 13, 2016
Permit type: Commercial Contracting
Description: Removal start on the 2nd and 5th floors of an existing commercial building. work includes removal of non-load bearing walls and non-fire walls / ceilings only. appicant proceeds at own risk. work pemitted to proceed to point of 1st inspection. reference permit application cbld1537326 and c.c.4113.39. additional removal start for other building systems. removal start valid for 45 days from 1/12/16. section 901.7 of the fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch is provided until the systems have been returned to service. means of egress shall be maintained in accordance with the ohio fire code 1411.2. contact chief david ridgely, [email protected] (614-221-3132 x4431) for info/ approval regarding impairment plan
Fee: $75.00 paid to City of Columbus, Ohio
Client: Olshan Prperties Available Data
Parcel #: 010247206
Permit #: RMST1601017
2329 Performance Way, Columbus, OH 43207
Date: Nov 18, 2015
Permit type: Remodeling
Description: Plan revision to cbld1530383 - drawing s1.1 office/warehouse saw cut plan revised, #4 bars at corners in wh, trench drain in washay, shop rails clairified and footings added. stepped footings and dimensions added, office added fibers. drawing s1.2 added section 13-15, detail 11 dock moved out, section 10 add #4
Fee: $300.00 paid to City of Columbus, Ohio
Client: Cec Real Estate Performance Llc Available Data
Parcel #: 010102565
Permit #: PLRE1539299
75 16Th Ave, Columbus, OH 43201
Date: Aug 17, 2015
Permit type: Remodeling
Description: Plan approval: conditional: fire suppression and fire alarm plans are required to be filed for review and approval. reviewed for compliance under: 2011 obc and icc a117.1-2009 with modifications in obc 1112.0. use/occupancy group: bldg complies with 509.7 which allows different construction types in same bldg. in this case s-2 open parking garage is beneath r-2 use on floors 2-3. s-2(parking) is separated from b and r-2 on first floor by 2-hr fire barrier. b office, s-1 property maintenance, and r-2 type a apartment are separated from each other by 1-hr fire barriers. construction type: first floor parking garage is ii-b, but columns and walls that support the 2-hr floor-clg above are also 2-hr rated. 1st flr apt, office and maintenance is vb. floor-clg above is 1-hr as reqd for dwelling unit separation. vb construction above 1st flr-clg. description of work: 75-81 e 16th ave, 3-sty mixed use bldg with parking (24 spaces), office, maintenance and 1, 1-br type a apt on first flr. 11, 2-sty 2-br apts abv. allowable height increased to 3 stories for sptinkler system. allowable area increased for street frontage. separate permits reqd for plmb, mech, elec, fire alarm and fire suppression. fire suppression systems: required. sprinkler system: nfpa13 in garage, offices, maintenance. nfpa13r in dwelling units. hazard class: tbd. standpipe system: n.a. riser demand (gpm): tbd. fire alarm system: required. record / history: new bldg. related to fndt1526436.
Valuation: $280,000,000
Fee: $5,400.00 paid to City of Columbus, Ohio
Client: Redstone Realty Company Llc Available Data
Parcel #: 010040616
Permit #: MBLD1526765
75 16Th Ave, Columbus, OH 43201
Date: Aug 13, 2015
Permit type: Remodeling
Description: 75-81 16th foundation to grade existing church building on site to be demolished plan approval: conditional (see page2) reviewed for compliance under: 2011 obc, and icc a117.1-2009 with modifications in obc 1112.0. work not included in this approval: plumbing, mechanical use/occupancy group: r-2/s-2/b separated mixed use construction type: iib/vb description of work: foundation only for a three story building with a concrete structure parking garage and business offices on the first floor, and wood framed apartments on the second and third floors. conditions of the occupancy: in accordance with section 1001.4 fire safety and evacuation plans must be provided for all occupancies and buildings, such fire safety and evacuation plans shall comply with the applicable provisions of sections 401.2 and 404 of the fire code and be approved by the division of fire. occupant load: not applicable maximum cap card: not required fire suppression systems: not required sprinkler system: none hazard class: standpipe system: riser demand (gpm): commodity class: aisle width: maximum height: alternative system: na fire alarm system: none record / history: new building no history page 2 conditional plan approval: per section 105.1.2, obc a conditional approval is a conditional license to proceed with construction or material up to the point where construction or materials objected to by the agency are to be incorporated into the building. conditions of the plan approval are issued as an adjudication order denying the issuance of a license and may be appealed in accordance with section 3781.19 of the revised code. the conditions of the plan approval are as follows: 1. nec 250.70 provide a grounding connector as required for the grounding electrode system in accordance with article 250, part iii. 2. obc 250.52 (a)(1) through (a)(7) bond all grounding electrodes as described in that are present in the new structure (i.e. concrete-encased electrode, ect.).
Valuation: $280,000,000
Client: Univest Co Available Data
Parcel #: 010040616
Permit #: FNDT1526436