Permits (3)
1001 New Hampshire, Lawrence, KS 66044
Date: Sep 13, 2011
Permit type: Commercial Contracting
Description: By accepting this permit permittee acknowledges the following: a) that time is of the essence; b) they have satisfied themselves that the owner has provided satisfactory r/w and/or easement(s) in accordance with city code to accommodate the work; c) to give city & adjacent residents 48 hrs advance notice of start of work; d) to construct the improvements as indicated on the permit plan record documents under plan file no. "2010-011a" and contract no. "1" with work not starting prior to 9-13-2011; (city agrees to early issuance of this permit subject to applicant agreeing to pay a triple permit fee if work is started before the start date indicated herein); e) to complete this work by the permit completion date of 11-13-2011; f) to coordinate with the work of all other contractors for timely completion; g) to remove/relocate/reconstruct unacceptable work to the satisfaction of the city; h) to remain responsible for the work until permit and bond are released; i) the city will notify the permittee by letter when this permit and the facility constructed under it are final accepted.
Parcel #: JA29230372400000000
Permit #: SEC6 70098924
1001 New Hampshire, Lawrence, KS 66044
Date: Mar 9, 2010
Permit type: Architecture
Description: Public works street lighting services plan review paccar 1301 chouteau traficway. unimproved street driveway culvert sizing / arts district parking garage. when a new development has perimeter or internal streets which are unimproved we will recommend that the streets be improved if practical. if improvement is impractical and the streets are to remain unimproved we will require that the developer's engineer determine the proper size and cross-section of roadside ditches or swales along the unimproved streets. although not specified it is hereby implied that all driveway culverts and new driveways regardless of the pipe material will be designed to handle the flow of a 10 year storm without over topping the driveway or adjacent street and shall be constructed in conformance with standard d-us. the engineer will also determine the approximate locations of driveways on the unimproved streets and indicate the proper flowline and size of the driveway culverts required. all of these items will be shown on the street or gradings plans. construction of the swales or ditches will be included in either the grading storm sewer or street permit as appropriate. the developer is responsible for maintenance of the ditches until the maintenance bond which was posted for the permit has expired. the developer will be advised of his requirement at the plats review commitee meeting. use the following language: "on an unimproved street include in the grading or street construction plans properly sized driveway culverts and roadside ditches for each lot". in other cases the city engineer's office will provide to the general public the service of sizing unimproved driveway culverts when the property is not part of an overall development of more that one lot and there is no developer or engineer otherwise involved with the project. the following procedure should be followed:. 1. obtain from the applicant or from the permit counter a contour map that shows the entire watershed with the driveway location clearly shown on the map. attached to the map should be the name address and phone number of the applicant and the pipe material to be used. 2. size the culvert to handle the flow from a 10 year storm without over topping the driveway or the adjacent street. the sizing must also be done to accomodate installation of the culvert in accordance with standard d-us. 3. give the counter staff the approved culvert size and then notify the applicant. if the driveway culvert installation is part of a new driveway installation a permit from public works will be required. if the driveway culvert is for a driveway at a location where street flooding is possible where multiple watersheds converge or any other unusual circumstances exist the review engineer shall notify the applicant that an analysis by a professional engineer will be required.
Parcel #: JA29230372400000000
Permit #: SEBI 1078
1001 New Hampshire, Lawrence, KS 66044
Date: Feb 24, 2010
Permit type: Commercial Contracting
Description: Construct new parking structure per plans reviewed for code compliance.
Parcel #: JA29230372400000000
Permit #: SE02 6449