Contractors DirectoryInformation on every contractor in United States

Blacketer Co.

225 S. Hurstbourne Parkway . Suite 103, Louisville, KY 40222

Service:
Architecture, Custom Home Design
Employees:
Alan Fields (Owner)

Status:
Active
Type:
Architect

Verified:
Status:Not verified

Blacketer Co. Additional Information Add Info

No additional information for Blacketer Co. yet.

Reviews Write Review

No reviews for Blacketer Co. yet.

Permits (47)

3101 Glenview Park Way, Louisville, KY 40222

Sponsored by Rehold
Information About Property

Date: Jun 14, 2016

Permit type: New Construction

Description: Lot# 32 - glenview park subdivision - section 3 - 3480 sf 1sf floor, 1673 sf 2nd floor of two story brick veneer with 2287 sf finished basement, 68 sf front porch, 68 sf side porch, 282 sf rear covered treated wood deck, 768 sf veranda with cooking porch, and 1103 sf attached garage. shall comply with 2013 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.7; handrails r311.7.8; guards r312; emergency egress sec r310; smoke alarms r314. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has transportation stamped and signed approval per pat brierly on 06/01/2016 for full build construction. - hh

Valuation: $95,000,000

Fee: $708.00 paid to City of Louisville, Kentucky

Client: Elizabeth Mcculley

Permit #: BL987579

816 Rugby Pl, Louisville, KY 40222

Sponsored by Rehold
Information About Property

Date: Feb 9, 2016

Permit type: Bathroom Remodeling

Description: 600 sfinterior renovation of existing bedroom into a new study and larger master bathroom with closetfor master bedroom of two storysingle family dwelling of wood frame construction. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2013 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r317. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. - hh

Valuation: $10,000,000

Fee: $50.00 paid to City of Louisville, Kentucky

Client: Brenda Boor

Permit #: BL975333

1800 Meremont Ridge Rd, Louisville, KY 40245

Sponsored by Rehold
Information About Property

Date: Oct 21, 2015

Permit type: Windows

Description: Lot#164 - meremont at long run subdivision - section 1 -2955 sf two story brick veneer with840 sf finished basement,90 sf front porch, and700 sf attached garage. shall comply with 2013 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.7; handrails r311.7.8; guards r312; emergency egress sec r310; smoke alarms r314. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has transportation stamped and signed approval per tammy markert on 10/21/2015 for full build construction. - hh

Valuation: $35,000,000

Fee: $343.00 paid to City of Louisville, Kentucky

Client: Maloney Realty Co Boland

Permit #: BL962378

15301 Beckley Crossing Dr, Louisville, KY 40245

Sponsored by Rehold
Information About Property

Date: Jul 21, 2015

Permit type: New Construction

Description: Lot 4 estates of beckley crossings. new house br vnr two story finished 1,351sqft basement. 625sqft attached garage. shall comply with krc 2013 including bathrooms e303; smoke/carbon detectors r314/315 and retaining walls over 4' . no commercial use allowed. shall not encroach any easements or required yards. separate permits required for any additional work. janicemjohnston

Valuation: $63,600,000

Fee: $455.00 paid to City of Louisville, Kentucky

Client: Jesse R Faught

Permit #: BL948913

5619 Glenview Falls Pl, Louisville, KY 40241

Sponsored by Rehold
Information About Property

Date: Mar 31, 2015

Permit type: New Construction

Description: Lot#23 - glenview parksubdivision - section2 -4765 sf two story brick veneer withunfinished basement,52 sf front porch, 272 sf rear porch,and1000 sf attached garage. shall comply with 2013 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.7; handrails r311.7.8; guards r312; emergency egress sec r310; smoke alarms r314. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has transportation stamped and signed approval perpat brierly on 03/27/2015for full build construction. - hh

Valuation: $60,000,000

Fee: $456.00 paid to City of Louisville, Kentucky

Client: Properties Lee

Permit #: BL935984

107 Vieux Carre Dr, Louisville, KY 40223

Date: Oct 27, 2014

Permit type: Remodeling

Description: Tenant fit-up for a b use group ; scope of work to entail the construction of intrior partition wall

Valuation: $2,375,000

Fee: $196.00 paid to City of Louisville, Kentucky

Client: C Holdings Llc V

Permit #: BL921364

15400 Beckley Crossing Dr, Louisville, KY 40245

Date: May 9, 2014

Permit type: New Construction

Description: Lot#13 -the estates of beckley crossingsubdivision -4813 sf two story brick veneer with3790 sf finished basement,492 sf rearporch and outsidekitchen, 181 sf front porch, and1400 sf attached garage. shall comply with 2014 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.7; handrails r311.7.8; guards r312; emergency egress sec r310; smoke alarms r314. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has transportation stamped and signed approval per tammy markert on 09-24-2013 for full build construction. builder has water management stamped and signed approval perdana scott on 04/25/2014 for full build construction with bond posted. builder has metro health department stamped and signed approval per johnmckinney on 05/07/2014 for full build construction.builder has transportation stamped and signed approval pertammy markerton 05/09/2014 for full build construction. - hh

Valuation: $220,000,000

Fee: $775.00 paid to City of Louisville, Kentucky

Client: Sanjay Gupta Jain Richa Jain

Permit #: 14BL2574

6606 Eagles Bluff Way, Louisville, KY 40241

Date: Apr 28, 2014

Permit type: New Construction

Description: Lot#77 -sanctuarybluffsubdivision -2250 sf two story brick veneer with1500 sf finished basement,308 sf treated wood deck, 64 sf front porch entry, and650 sf attached garage. shall comply with 2014 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.7; handrails r311.7.8; guards r312; emergency egress sec r310; smoke alarms r314. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maximum u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. - hh

Valuation: $39,000,000

Fee: $357.00 paid to City of Louisville, Kentucky

Client: Properties Llc Rap

Permit #: 14BL2430

4530 Bishop Ln, Watterson Park, KY 40218

Date: Feb 17, 2014

Permit type: Remodeling

Description: Renovation of an existing commercial space to increase the tenant space from 3700 square feet to 5000 square ft. tenant seperation to be maintained and tenant space to be 100% suppressed, (must re-work sprinkler heads as required per nfpa 13 and the 2013 kbc). all work to be of non combustible material. all work to meet the requirements of the 2013 kbc. mam

Valuation: $1,500,000

Fee: $650.00 paid to City of Louisville, Kentucky

Client: Hurstbourne Lane Partn 215

Permit #: 14BL1393

4106 Altawood Ct, Louisville, KY 40245

Date: Nov 8, 2013

Permit type: New Construction

Description: First fl reno for tenant fit up for ophthalmology associates located at 3810 springhurt blvd. in the meridian building. shall comply with 2007 kbc.separate permit for electrical,hvac,plumbing,fire detection modification or sprinkler head relocation.all areas are to be accessible per ansi117.1 and chapter 11. occ load 83 -cc

Valuation: $35,500,000

Fee: $494.00 paid to City of Louisville, Kentucky

Client: Stephen Hoffmann Susan Hoffmann

Permit #: 13BL5849

6702 Glen Springs Ct, Louisville, KY 40222

Date: Aug 23, 2013

Permit type: New Construction

Description: 2214 sf fire damage repair. only single family use is allowed without a conditional use permit. no extended stay use is allowed at this address. shall comply with 2007 krc and 2009 iecc. all stamped truss details must be delivered to the field inspector on site. this fire damage repair is a complete rebuild of the garage and sunroom area and a complete new roof structure. jm

Valuation: $59,000,000

Fee: $472.00 paid to City of Louisville, Kentucky

Client: Raymond Paul Jr Minnillo Diane Minnillo

Permit #: 13BL4777

6605 Eagles Bluff Way, Louisville, KY 40241

Date: Jul 31, 2013

Permit type: New Construction

Valuation: $35,000,000

Fee: $353.00 paid to City of Louisville, Kentucky

Client: Properties Llc Rap

Permit #: 13BL4409

16714 Taddington Pl, Louisville, KY 40245

Date: Jun 14, 2013

Permit type: New Construction

Description: Lots 105/106 consolidated - gardiner park subdivision - section i - 2270 sf one story single family dwelling with 144 sf treated wood deck, and 685 sf attached garage. shall comply with krc - 2007. separate permit required for electrical, plumbing, and hvac. - hh

Valuation: $28,000,000

Client: Park Ii Llc Gardiner

Permit #: 13BL1342

5213 Moccasin Trl, Indian Hills, KY 40207

Date: Mar 8, 2013

Permit type: New Construction

Description: 1675 sf one story addition of wood frame construction of two story of single family dwelling. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r313. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 03/082013 for full build construction. builder has city of indian hills letter of compliance approval per jim graven on 03/06/2013 for full build construction. - hh

Valuation: $15,800,000

Client: David E Russell

Permit #: 355838

16530 Briston Avon Ln, Louisville, KY 40245

Date: Feb 20, 2013

Permit type: New Construction

Description: Lot# 14 - gardiner park subdivision - section i - 2170 sf one story brick veneer with unfinished basement, 144 sf treated wood deck, and 685 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.5.3; handrails r311.5.6; guards r312; emergency egress sec r310; smoke alarms r313. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 02/18/2013 for full build construction. builder has load calcs for flush beam for roof, first floor flush beam, first floor flush beam, roof drop beam, and first floor flush beam. - hh - permit modification of 1600sf finished basement. no other changes to aproved plans. 1600 sf + 2999 sf = 4599 sf. - hh

Valuation: $27,500,000

Client: Park Ii Llc Gardiner

Permit #: 354377

11205 Bodley Dr, Louisville, KY 40223

Date: Nov 8, 2012

Permit type: New Construction

Description: Infill - 7101 sf two story brick veneer with 2780 sf finished basement, and 1250 sf attached garage.

Valuation: $120,000,000

Client: Vasu Kakarlapudi & Ram V

Permit #: 346247

3755 Upper River Rd, Louisville, KY 40207

Date: Sep 14, 2012

Permit type: New Construction

Description: Lot# 16 - mockingbird valley river bluff subdivision - 10283 sf two story brick veneer with 3218 sf finished basement, 460 sf treated wood deck, and 2117 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r404.1; basement. walls r 404; stairs r311.5.3; handrails r311.5.6; guards r312; emergency egress sec r310; smoke alarms r313. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 09/14/2012 for full build construction. builder has water management stamped and signed approval with $2500.00 bond posted on 09/12/2012 for full build construction. - hh --- permit modified for 750 sf retaining wall at right side of property line....16078 + 750 = 16828 sf. builder has stamped engineered drawings. no other changes to approved plans. - hh

Valuation: $250,000,000

Client: Trust Homestar

Permit #: 341570

1912 Mockingbird Bluff Ln, Louisville, KY 40207

Date: Jun 8, 2012

Permit type: New Construction

Description: Infill 7669 sf two story brick veneer with 2300 sf finished basement, and 1840 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; basement. walls r 404; stairs r314; handrails r315; guards r316; emergency egress sec r310; smoke alarms r317. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 04/22/2012 for full build construction. builder has water management stamped and signed approval with $2500.00 bond posted per john selch on 04/23/2012 for full build construction. - hh

Valuation: $110,000,000

Client: Gregory C Postel Sally L Postel

Permit #: 331494

6124 Springhouse Farm Ln, Louisville, KY 40222

Date: Jun 8, 2012

Permit type: New Construction

Description: Lot# 33 - glenview springs subdivision - two story brick veneer with 2126 sf finished basement, and 690 sf attached garage. shall comply with 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; basement. walls r 404; stairs r314; handrails r315; guards r316; emergency egress sec r310; smoke alarms r317. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply with ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management single lot residential grading and erosion prevention and sediment control certificate signed and approved per john selch on 06/08/2012 for full build construction. - hh --- permit modified for 318 sf retaining wall at right side of property line....5251 + 318 = 5569. builder has stamped engineered drawings. no other changes to approved plans. - hh

Valuation: $92,500,000

Client: William & Joeley Brewer

Permit #: 331484

8702 Stockport Rd, Hurstbourne, KY 40222

Date: Apr 27, 2012

Permit type: Bathroom Remodeling

Description: 160 sf second floor master bathroom renovation of two story singe family dwelling. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2007 krc including rafter span r802.5; floor joist span r502.3; ceiling joist span r802.4; smoke alarms r317. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .35 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. - hh

Valuation: $1,000,000

Client: H Wilson Qualified Per Karen

Permit #: 327444

All data is collected from public records. We do not guarantee accuracy of information.