Permits (2)
104 Pembroke Ave, Nashville, TN 37205
Date: Nov 27, 2012
Permit type: Windows
Description: New detached accessory structure.| description| | cladding & trim| - exterior cladding material to be wood or cement fiberboard and may match the exposure of the main structure. if siding material/exposure does not match the main structure then lap siding to be 6-width material with a maximum of 5 inches of exposure. siding material to be smooth and free of knots rough unfinished appearance and other imperfections. simulated wood stamp is not appropriate. | - all/any trim railings vents and associated type elements are to be wood or cement fiberboard. clad material is not approved. wood or cement fiberboard shall be a smooth face material void of any simulated wood grain pattern or rough unfinished appearance. all exposed exterior lumber should be grade number #1 or #2. lower grade lumber is unsuitable for exterior work. | - 2 4 inches wood corner boards are typical on the face of each exposed corner. lumber to be of an appropriate trim grade (smooth and square). stud wall lumber is not appropriate. | - 2 4 inches wood casing typical at doors and windows. lumber to be of an appropriate trim grade (smooth and square). stud wall lumber is not appropriate. | windows & doors| - windows shall be wood with single-light or fully-simulated divided-light sashes. muntins are to be factory installed with an exterior muntin interior muntin and a spacer within the double-paned glass. window manufacturer and type must be approved by mhzc staff prior to installation.| - windows on clapboard structures shall not have brick-mold. | - overhead garage door and pedestrian entry doors may be steel with simple panel design. doors to be approved by staff prior to installation. | roof| - roof material may match the main structure. if roof material is not to match main structure then roofing to be asphalt composite 3-tab shingle. unusual colors such as blue are not approved. roofing color to be approved by staff prior to installation. | foundation| - foundation to be a maximum of si(6) inches in height from grade. | general specifications| - alterations to be constructed in accordance with attached elevations. any deviation from the approved plans could result in changes being reversed to reflect the approved drawings. please note: mhzc staff may have added notes to the submitted drawings. | - all measurements and relationships of existing conditions and new construction shall be field checked for accuracy with approved plans at the responsibility of the applicant. inaccuracies or differences should be reported to mhzc staff prior to continuing with the project. | - any substitutions or deviation from the approved work requires further review and approval by the mhzc prior to work being undertaken. | - the work items listed are approved in accordance with the adopted design guidelines and are not applicable beyond the unique facts and circumstances of this particular application. | - this permit becomes invalid twelve months after issue date. expired permits must be reissued prior to work being undertaken. | | - this is not a building permit. no work can begin without the appropriate review and approval by the metropolitan department of codes administration: howard school building campus (615) 862-6500.
Parcel #: 13002006500
Permit #: HCN 201200349
104 Pembroke Ave, Nashville, TN 37205
Date: Nov 27, 2012
Permit type: Roofing
Description: Construct rear addition (screened porch with bonus room above)| description| | foundation| - foundation height shall match the existing house. | - exterior foundation material if more than siinches are exposed shall exactly match the existing structure or be parged/stuccoed. | structure | - first story to be open (screened) with brick piers and a brick chimney.| - primary ridge height shall match the ridge of the existing roof. | roofing| - roofing material shall be asphalt composite shingles to match existing. | - gutters shall be simple metal gutters. | windows & doors| - windows shall be wood with single-light or fully-simulated divided-light sashes. muntins are to be factory installed with an exterior muntin interior muntin and a spacer within the double-paned glass. window manufacturer and type must be approved by mhzc staff prior to installation. | - four (4) inch (nominal) wood casings are required around doors windows and vents within clapboard walls. | - windows on clapboard structures shall not have brick-mold. | siding & trim| - siding and trim shall be wood or smooth-faced cement-fiberboard (e.g.: hardiplank). if siding exposure is not matched to that of the existing house then it shall have a maximum reveal of five (5) inches. | - 4 inches (nominal) wood corner-boards are required at the face of each exposed corner. | hvac | - hvac/mechanical/utility vents pipes lines and all associated components condensers or boxes shall be located behind the midpoint of the structure on a non-street facade. | general specifications| - alterations to be constructed in accordance with attached elevations. any deviation from the approved plans could result in changes being reversed to reflect the approved drawings. please note: mhzc staff may have added notes to the submitted drawings. | - all measurements and relationships of existing conditions and new construction shall be field checked for accuracy with approved plans at the responsibility of the applicant. inaccuracies or differences should be reported to mhzc staff prior to continuing with the project. | - any substitutions or deviation from the approved work requires further review and approval by the mhzc prior to work being undertaken. | - the work items listed are approved in accordance with the adopted design guidelines and are not applicable beyond the unique facts and circumstances of this particular application. | - this permit becomes invalid twelve months after issue date. expired permits must be reissued prior to work being undertaken. | | - this is not a building permit. no work can begin without the appropriate review and approval by the metropolitan department of codes administration: howard school building campus (615) 862-6500. |.
Parcel #: 13002006500