Contractors DirectoryInformation on every contractor in United States

Wm J Shaffer Associates Inc

P O BOX 1386, Columbus, OH 43216


Contact Information

Phone:
(614) 488-3446
Service:
New Construction, Hvac, Remodeling, Commercial Contracting, Demolition, Miscellaneous
Employees:
William J Shaffer, WILLIAM J SHAFFER (Owner)

License:
Ohio #OHG4193
Status:
Active

Verified:
Status:Not verified

Wm J Shaffer Associates Inc Additional Information Add Info

No additional information for Wm J Shaffer Associates Inc yet.

Reviews Write Review

No reviews for Wm J Shaffer Associates Inc yet.

Permits (9)

3415 Vision Dr, Columbus, OH 43219

Date: Jul 8, 2016

Permit type: Remodeling

Description: Replacement of case work and flooring in day care. no fire alarm or sprinkler work

Valuation: $7,500,000

Fee: $1,350.00 paid to City of Columbus, Ohio

Client: Georgetown Chase Available Data

Parcel #: 010236091

Permit #: INTR1618783

3415 Vision Dr, Columbus, OH 43219

Date: Jan 14, 2015

Permit type: Commercial Contracting

Fee: $150.00 paid to City of Columbus, Ohio

Client: Georgetown Chase Phase I Llc Available Data

Permit #: TRIP1500166

3415 Vision Dr, Columbus, OH 43219

Date: Dec 23, 2013

Permit type: Commercial Contracting

Fee: $150.00 paid to City of Columbus, Ohio

Client: Georgetown Chase Phase I Llc Available Data

Parcel #: 010236091

Permit #: TRIP1300827

3415 Vision Dr, Columbus, OH 43219

Date: May 21, 2013

Permit type: Remodeling

Description: 3415 vision drive - j p morgan chase - easton center - conference room c2-8e-02 - video conferencing interior only alterations in existing multi-story commercialoffice building to add new video conferencing system to an existing conference room and also build a new 17 sf av closet, non structural demolition new partitions. no change of use. plan approval: final interior alteration reviewed for compliance under: 2011 obc and icc a117.1-2009 work included in this approval: structural, mechanical and electrical work not included in this approval: fire suppression use / occupancy group: b, business space within multi-story office building construction type: i-a / fully sprinklered with alarm system throughout description of the work: interior only alterations to the existing conference room #c2-8e-02 to add equipment for videoconferencing. work will also create 17 sf closet for av equipment in the corner of the adjacent c2-6e-01 board room on the common wall with the remodeled videoconferencing room. work includes non-structural demolition, new partition walls and door for the av closet, videoconferencing display panels and related wiring including three new circuits (two for new ceiling fans and one for the av power zone)from existing panels. one new sprinkler head with pipe run will need to be extended from the existing sprinkler system for the ceiling of the new av closet; which will require separate submittal, approval and permit. conditions of the occupancy: in accordance with section 1001.4 fire safety and evacuation plans shall be provided for all occupancies and buildings. such fire safety and evacuation plans shall comply with the applicable provisions of sections 401.2 and 404 of the fire code and may be approved by the division of fire to obtain a certificate of occupancy. design occupant load: no change maximum capacity card: not required fire suppression systems: required system installed sprinkler system: existing to be modified nfpa13 fire alarm system: existing not modified manual / automatic / supervision only/ non-required system installed notes / comments / conditions of the plan approval: none record / history: existing multi-story office building with fire alarm and fire sprinkler systems throughout. franklin county auditors parcel # 010-236091.

Valuation: $10,000,000

Fee: $1,200.00 paid to City of Columbus, Ohio

Client: Georgetown Chase Available Data

Parcel #: 010236091

Permit #: INTR1316212

1800 Watermark Dr, Columbus, OH 43215

Date: Aug 24, 2012

Permit type: Remodeling

Description: 1800 watermark dr = 4th floor - suite 420 plan approval: final notes / comments / conditions of the plan approval: none plan approval includes: structural, mechanical, and electrical reviewed for compliance under: 2011 obc and icc/ansi a117.1-2009 use / occupancy group: b, business ¿ office construction type: ii-b description of the work: tenant renovation of 460 sq ft portion of existing 8,122 net square foot tenant office space within existing four-story office building that is fully sprinklered with a combination automatic/manual fire alarm system. renovation adds non-rated walls and doors to create three new office compartments (rooms 420-422); requires only minor relocation of existing ceiling luminaires (3) and air transfer devices (2); and adds electrical wiring for new wall light switches (3) and power receptacles (2). the existing fire alarm system and fire sprinkler systems are not modified or disturbed. ceiling, wall and floor finishes will be restored. conditions, limitations, variances and special stipulations of the occupancy: none design occupant load: 82 persons maximum capacity card: not required fire suppression systems: existing throughout building sprinkler system: existing nfpa13, not modified fire alarm system: existing not modified manual / automatic storage: not applicable record / history: four-story 95,280 sf steel, concrete and masonry office building with elevators, fire sprinkler system and manual/automatic fire alarm system. accela files contain numerous interior renovation and related permits and franklin county auditor parcel # 010-205705 is confirmed with address.

Valuation: $3,000,000

Fee: $1,200.00 paid to City of Columbus, Ohio

Client: Highlights For Children Corp Available Data

Parcel #: 010205705

Permit #: INTR1227549

89 Nationwide Blvd, Columbus, OH 43228

Date: Jan 15, 2010

Permit type: Remodeling

Description: 89 east nationwide - 1st floor restaurant revision to permit intr0933279

Fee: $300.00 paid to City of Columbus, Ohio

Client: Naughten Partners Limited Partnership Available Data

Parcel #: 010000624

Permit #: PLRE1001001

89 Nationwide Blvd, Columbus, OH 43228

Date: Oct 30, 2009

Permit type: Kitchen Remodeling

Description: 89 e. nationwide - 1st floor restaurant alterations michael o'toole's restaurant in existing masonry/frame sprinkled/alarmed building code: (2007 obc ) type (iii-b (602.3)) use (a-2 (303.1) ) design occupant load: 139 seating certificate of occupancy :( ) ( ) ( ) (is required) conditions, limitations, variances and special stipulations of the occupancy: none. fire suppression systems: sprinkler system: existing modified (required throughout building) hazard class: light in dining areas, ordinary i in kithcen & service areas riser demand: unchanged standpipe system: none alternative system: required (wet chemical in kitchen exhaust hood) fire alarm system: existing modified storage: not applicable commodity class: description: aisle width: maximum height storage: live load: not applicable

Valuation: $27,500,000

Fee: $1,650.00 paid to City of Columbus, Ohio

Client: Naughten Partners Limited Partnership Available Data

Parcel #: 010000624

Permit #: INTR0933279

89 Nationwide Blvd, Columbus, OH 43228

Date: Jul 28, 2009

Permit type: Remodeling

Description: 89 e nationwide blvd removal start to clean up and remove non structural walls and non rated ceilings and walls in a multi story restaruant building applicant proceeds at own risk additional permits required to remove other building systems

Valuation: $850,000

Fee: $75.00 paid to City of Columbus, Ohio

Client: Naughten Partners Limited Partnership Available Data

Parcel #: 010000624

Permit #: RMST0923247

7619 Huntington Park Dr, Columbus, OH 43216

Date: Dec 11, 2007

Permit type: Remodeling

Description: Interior renovation to existing one story, fully sprinklered and alarmed, wood frame restaurant, mitchell's steakhouse. work includes structural, plumbing, mechanical and electrical. code: (2007 obc ) type (v-b (602.5)) use (a-2 (303.1) ) design occupant load: no change certificate of occupancy :(existing building) ( ) ( ) ( ) conditions, limitations, variances and special stipulations of the occupancy: none. fire suppression systems: sprinkler system existing modified hazard class: riser demand: standpipe system none alternative system none fire alarm system: existing modified storage: not applicable commodity class: description: aisle width: maximum height storage: live load: unchanged

Fee: $1,647.49 paid to City of Columbus, Ohio

Client: Cameron Mitchell Available Data

Permit #: 07110-00000-03154

Wm J Shaffer Associates Inc - Similar Contractors