Martin Heating Ac
1353 PLUM CREEK RD, Taylorsville, KY 40071
Contact Information
Martin Heating Ac Additional Information Add Info
No additional information for Martin Heating Ac yet.
Reviews Write Review
No reviews for Martin Heating Ac yet.
Permits (24)
303 Iowa Ave, Louisville, KY 40208
Date: May 20, 2015
Permit type: Hvac
Description: Cc
Valuation: $1,200,000
Client: Winks Llc Four Available Data
Permit #: HV941817
305 Iowa Ave, Louisville, KY 40208
Date: May 20, 2015
Permit type: Hvac
Description: Cc
Valuation: $1,200,000
Client: Winks Llc Four Available Data
Permit #: HV941818
3003 Pamela Way, Louisville, KY 40220
Date: Dec 17, 2014
Permit type: Hvac
Description: Card
Valuation: $200,000
Client: Point Condominiums Cou Hikes Available Data
Permit #: HV927051
307 Iowa Ave, Louisville, KY 40208
Date: Nov 6, 2014
Permit type: Hvac
Description: Cc printout certified by acca to meet all requirements of manual j 8th ed. right-suite univ ersal 7.1.17 rsu01030 2015-feb-05 15:49:47 c:usersjessicadocumentsmartin heating and airkuster iowa apts.rup calc = mj8 orientation = page 1 project summary job: date: nov 05, 2014 (rest of house) by: jessica m. cox martin heating and air conditioning, inc. 1353 plum creek road, taylorsville, ky 40071 phone: 502-477-2508 email: jessica@martinheatingandac.com web: martinheatingandac.com project information for: iowa - kuster notes: design information weather: louisville bowman field, ky, us winter design conditions summer design conditions outside db 0 f outside db 97 f inside db 73 f inside db 73 f design td 73 f design td 24 f daily range m relative humidity 50 % moisture difference 58 gr/lb heating summary sensible cooling equipment load sizing structure 25846 btuh structure 10203 btuh ducts 0 btuh ducts 0 btuh central vent (0 cfm) 0 btuh central vent (0 cfm) 0 btuh humidification 0 btuh blower 0 btuh piping 0 btuh equipment load 25846 btuh use manufacturer's data n rate/swing multiplier 1.02 infiltration equipment sensible load 10376 btuh method simplified latent cooling equipment load sizing construction quality average fireplaces 0 structure 470 btuh ducts 0 btuh heating cooling central vent (0 cfm) 0 btuh area (ft) 516 516 equipment latent load 470 btuh volume (ft) 4644 4644 air changes/hour 0.31 0.16 equipment total load 10846 btuh equiv. avf (cfm) 24 12 req. total capacity at 0.70 shr 1.2 ton heating equipment summary cooling equipment summary make n/a make n/a trade n/a trade n/a model n/a cond n/a gama id n/a coil n/a ari ref no. n/a efficiency n/a efficiency n/a heating input sensible cooling 0 btuh heating output 0 btuh latent cooling 0 btuh temperature rise 0 f total cooling 0 btuh actual air flow 0 cfm actual air flow 0 cfm air flow factor 0 cfm/btuh air flow factor 0 cfm/btuh static pressure 0 in h2o static pressure 0 in h2o space thermostat n/a load sensible heat ratio 0 printout certified by acca to meet all requirements of manual j 8th ed. right-suite univ ersal 7.1.17 rsu01030 2015-feb-05 15:49:47 c:usersjessicadocumentsmartin heating and airkuster iowa apts.rup calc = mj8 orientation = page 2 project summary job: date: nov 05, 2014 down west by: jessica m. cox martin heating and air conditioning, inc. 1353 plum creek road, taylorsville, ky 40071 phone: 502-477-2508 email: jessica@martinheatingandac.com web: martinheatingandac.com project information for: iowa - kuster notes: design information weather: louisville bowman field, ky, us winter design conditions summer design conditions outside db 0 f outside db 97 f inside db 73 f inside db 73 f design td 73 f design td 24 f daily range m relative humidity 50 % moisture difference 58 gr/lb heating summary sensible cooling equipment load sizing structure 28021 btuh structure 11741 btuh ducts 0 btuh ducts 0 btuh central vent (0 cfm) 0 btuh central vent (0 cfm) 0 btuh humidification 0 btuh blower 0 btuh piping 0 btuh equipment load 28021 btuh use manufacturer's data n rate/swing multiplier 1.02 infiltration equipment sensible load 11940 btuh method simplified latent cooling equipment load sizing construction quality average fireplaces 0 structure 494 btuh ducts 0 btuh heating cooling central vent (0 cfm) 0 btuh area (ft) 516 516 equipment latent load 494 btuh volume (ft) 4644 4644 air changes/hour 0.33 0.16 equipment total load 12435 btuh equiv. avf (cfm) 25 13 req. total capacity at 0.70 shr 1.4 ton heating equipment summary cooling equipment summary make n/a make n/a trade n/a trade n/a model n/a cond n/a gama id n/a coil n/a ari ref no. n/a efficiency n/a efficiency n/a heating input sensible cooling 0 btuh heating output 0 btuh latent cooling 0 btuh temperature rise 0 f total cooling 0 btuh actual air flow 0 cfm actual air flow 0 cfm air flow factor 0 cfm/btuh air flow factor 0 cfm/btuh static pressure 0 in h2o static pressure 0 in h2o space thermostat n/a load sensible heat ratio 0 printout certified by acca to meet all requirements of manual j 8th ed. right-suite univ ersal 7.1.17 rsu01030 2015-feb-05 15:49:47 c:usersjessicadocumentsmartin heating and airkuster iowa apts.rup calc = mj8 orientation = page 3 project summary job: date: nov 05, 2014 up east by: jessica m. cox martin heating and air conditioning, inc. 1353 plum creek road, taylorsville, ky 40071 phone: 502-477-2508 email: jessica@martinheatingandac.com web: martinheatingandac.com project information for: iowa - kuster notes: design information weather: louisville bowman field, ky, us winter design conditions summer design conditions outside db 0 f outside db 97 f inside db 73 f inside db 73 f design td 73 f design td 24 f daily range m relative humidity 50 % moisture difference 58 gr/lb heating summary sensible cooling equipment load sizing structure 24476 btuh structure 10278 btuh ducts 0 btuh ducts 0 btuh central vent (0 cfm) 0 btuh central vent (0 cfm) 0 btuh humidification 0 btuh blower 0 btuh piping 0 btuh equipment load 24476 btuh use manufacturer's data n rate/swing multiplier 1.02 infiltration equipment sensible load 10453 btuh method simplified latent cooling equipment load sizing construction quality average fireplaces 0 structure 494 btuh ducts 0 btuh heating cooling central vent (0 cfm) 0 btuh area (ft) 516 516 equipment latent load 494 btuh volume (ft) 4644 4644 air changes/hour 0.33 0.16 equipment total load 10947 btuh equiv. avf (cfm) 25 13 req. total capacity at 0.70 shr 1.2 ton heating equipment summary cooling equipment summary make n/a make n/a trade n/a trade n/a model n/a cond n/a gama id n/a coil n/a ari ref no. n/a efficiency n/a efficiency n/a heating input sensible cooling 0 btuh heating output 0 btuh latent cooling 0 btuh temperature rise 0 f total cooling 0 btuh actual air flow 0 cfm actual air flow 0 cfm air flow factor 0 cfm/btuh air flow factor 0 cfm/btuh static pressure 0 in h2o static pressure 0 in h2o space thermostat n/a load sensible heat ratio 0 printout certified by acca to meet all requirements of manual j 8th ed. right-suite univ ersal 7.1.17 rsu01030 2015-feb-05 15:49:47 c:usersjessicadocumentsmartin heating and airkuster iowa apts.rup calc = mj8 orientation = page 4 project summary job: date: nov 05, 2014 up west by: jessica m. cox martin heating and air conditioning, inc. 1353 plum creek road, taylorsville, ky 40071 phone: 502-477-2508 email: jessica@martinheatingandac.com web: martinheatingandac.com project information for: iowa - kuster notes: design information weather: louisville bowman field, ky, us winter design conditions summer design conditions outside db 0 f outside db 97 f inside db 73 f inside db 73 f design td 73 f design td 24 f daily range m relative humidity 50 % moisture difference 58 gr/lb heating summary sensible cooling equipment load sizing structure 23353 btuh structure 10740 btuh ducts 0 btuh ducts 0 btuh central vent (0 cfm) 0 btuh central vent (0 cfm) 0 btuh humidification 0 btuh blower 0 btuh piping 0 btuh equipment load 23353 btuh use manufacturer's data n rate/swing multiplier 1.02 infiltration equipment sensible load 10923 btuh method simplified latent cooling equipment load sizing construction quality average fireplaces 0 structure 470 btuh ducts 0 btuh heating cooling central vent (0 cfm) 0 btuh area (ft) 516 516 equipment latent load 470 btuh volume (ft) 4644 4644 air changes/hour 0.31 0.16 equipment total load 11393 btuh equiv. avf (cfm) 24 12 req. total capacity at 0.70 shr 1.3 ton heating equipment summary cooling equipment summary make n/a make n/a trade n/a trade n/a model n/a cond n/a gama id n/a coil n/a ari ref no. n/a efficiency n/a efficiency n/a heating input sensible cooling 0 btuh heating output 0 btuh latent cooling 0 btuh temperature rise 0 f total cooling 0 btuh actual air flow 0 cfm actual air flow 0 cfm air flow factor 0 cfm/btuh air flow factor 0 cfm/btuh static pressure 0 in h2o static pressure 0 in h2o space thermostat n/a load sensible heat ratio 0
Valuation: $1,000,000
Client: Winks Llc Four Available Data
Permit #: HV922764
3003 Pamela Way, Louisville, KY 40220
Date: Nov 6, 2014
Permit type: Hvac
Description: Cc
Valuation: $400,000
Client: Point Condominiums Cou Hikes Available Data
Permit #: HV922765
3101 Pamela Way, Louisville, KY 40220
Date: Aug 19, 2014
Permit type: Hvac
Description: Replacing 1 combo unit
Valuation: $350,000
Client: May Kuster Revocable T Helen Available Data
Permit #: 14HV9292
8601 Fernview Dr, Louisville, KY 40291
Date: Mar 12, 2013
Permit type: Residential
Description: Cc
Valuation: $450,000
Client: James D Jr & Carolyn A Keene Available Data
Permit #: 356029
5802 Valley Park Dr, Louisville, KY 40299
Date: Jan 20, 2012
Permit type: Remodeling
Description: Card
Valuation: $1,800,000
Client: Brown Custom Builders Worth Available Data
Permit #: 319442
6815 Shibley Ave, Louisville, KY 40291
Date: May 10, 2011
Permit type: Hvac
Description: Check 11656
Valuation: $500,000
Client: Family Trust Lee Available Data
Permit #: 296436
2704 Masemure Ct, Louisville, KY 40220
Date: Jan 29, 2009
Permit type: Hvac
Description: Ck 10386 heating unit heating unit
Valuation: $200,000
Client: Apartments Inc Glenbrook Available Data
Permit #: 219632
2710 Masemure Ct, Louisville, KY 40220
Date: Jan 29, 2009
Permit type: Hvac
Description: Ck 10386 heating unit heating unit
Valuation: $200,000
Client: Apartments Inc Glenbrook Available Data
Permit #: 219633
2530 Kings Hwy, Kingsley, KY 40205
Date: May 13, 2008
Permit type: Hvac
Description: Ck 9995 1 combo unit
Valuation: $800,000
Client: Allen Land Available Data
Permit #: 196097
3003 Pamela Way, Louisville, KY 40220
Date: Apr 23, 2008
Permit type: Hvac
Description: Check 9955 installing 4 new a/c's moving two units from roof to ground
Valuation: $1,000,000
Client: Properties Llc Dot Available Data
Permit #: 194175
7412 Mayrow Dr, Louisville, KY 40291
Date: Mar 18, 2008
Permit type: Hvac
Description: Ck 9861 1 combo unit
Valuation: $100,000
Client: Garnett P & Charlene Grant Available Data
Permit #: 190456
412 Eline Ave, Louisville, KY 40207
Date: Feb 20, 2008
Permit type: Hvac
Description: Ck 9824 1 combo unit
Valuation: $500,000
Client: Aaron J Berutti Available Data
Permit #: 187409
2712 Masemure Ct, Louisville, KY 40220
Date: Mar 29, 2006
Permit type: Hvac
Description: Check 8787
Valuation: $100,000
Client: Bruce & Leslie Dettlinger Available Data
Permit #: 108340
9803 Creekwood Rd, Meadowbrook Farm, KY 40223
Date: Mar 29, 2006
Permit type: Hvac
Description: Check 8787
Valuation: $100,000
Client: Todd A Davis Available Data
Permit #: 108341
3316 Noe Way, Louisville, KY 40220
Date: Mar 30, 2005
Permit type: Hvac
Description: Ck#8247-present owners bought property recently several units have been replaced and do not have inspection stickers on them
Valuation: $250,000
Client: Way Llc Noe Available Data
Permit #: 59028
2702 Masemure Ct, Louisville, KY 40220
Date: Mar 22, 2005
Permit type: Hvac
Description: Ck#8234
Valuation: $150,000
Client: Apartments Inc Glenbrook Available Data
Permit #: 58397
2706 Masemure Ct, Louisville, KY 40220
Date: Mar 22, 2005
Permit type: Hvac
Description: Ck#8234
Valuation: $150,000
Client: Apartments Inc Glenbrook Available Data
Permit #: 58396