Electrical Construction Mgmt
10801 Electron Dr Ste 500, Louisville, KY 40299
Contact Information
Electrical Construction Mgmt Additional Information Add Info
No additional information for Electrical Construction Mgmt yet.
Reviews Write Review
No reviews for Electrical Construction Mgmt yet.
Permits (18)
399 E Witherspoon St, Louisville, KY 40202
Date: Mar 31, 2014
Permit type: Electrical
Description: Install 200a meter with a feed through panel and feed a temporary communications unit.
Valuation: $250,000
Client: Development Corp Waterfront Available Data
Permit #: 14EL3708
3413 Tarragon Rd, Louisville, KY 40219
Date: Jul 25, 2013
Permit type: Electrical
Description: Card- wire new house
Valuation: $350,000
Client: D J Associates Inc J Available Data
Permit #: 13EL3189
3413 Tarragon Rd, Louisville, KY 40219
Date: Jul 25, 2013
Permit type: Electrical
Description: Card- temp pole
Valuation: $50,000
Client: D J Associates Inc J Available Data
Permit #: 13EL3190
3410 Tarragon Rd, Louisville, KY 40219
Date: Oct 26, 2011
Permit type: New Construction
Description: Lot # 12 - cherokee acres subdivision - 1368 one story brick veneer over vented crawlspace and 511 sf attached garage. shall comply to 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; basement. walls r 404; stairs r314; handrails r315; guards r316; emergency egress sec r310; smoke alarms r317. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish basement. bedrooms not allowed in basement without emergency egress per sec r310. shall comply to ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed ,shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. fenestration (windows & doors) - .40 maxium u value. shall provide written window installation instructions provided by the window manufacturer per r613.1. same shall be delivered to the field inspector. builder has water management stamped and signed approval per john selch for full build construction with verified moe of 462.2. - hh
Valuation: $8,500,000
Client: D J Associates Inc J Available Data
Permit #: 291052
3410 Tarragon Rd, Louisville, KY 40219
Date: Oct 10, 2011
Permit type: New Construction
Description: Lot # 12 - cherokee acres subdivision --- foundation only. one story shall comply to 2007 krc including foundation r403. shall not encroach any easements or required yards. shall not go beyond foundation. foundation is at owners risk per sec 106.3.3 krc. builder has water management stamped and signed approval per john selch on 10/10/11 for foudation only with moe to be verified. - hh
Valuation: $1,500,000
Client: D J Associates Inc J Available Data
Permit #: 291056
3405 Tarragon Rd, Louisville, KY 40219
Date: Mar 16, 2011
Permit type: New Construction
Description: Lot #8 cherokee acres-1368 sf one story br.ven./frame single family residence on crawlspace, with 410 sf attached garage, plus 54 sf front porch, plus 60 sf deck. shall comply to 2007 krc. approvals in case file. see plans on site. shall provide written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector. has all lvl beam calcs shall be delivered to field inspector. approved plans per irc section 106.3.1. mi
Valuation: $8,500,000
Client: D J Associates Inc J Available Data
Permit #: 292014
3415 Tarragon Rd, Louisville, KY 40219
Date: Sep 18, 2009
Permit type: New Construction
Description: Lot # 3 cherokee acres - 1440 sf one story br. ven. with unfinished bsmt.34 sf covered ft porch ,83 sf covered rear porch , and 400 sf att. garage. shall comply to 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; footings r403; foundation walls r 404; stairs r311.5; handrails r311.5.6; guards r312; emer. egress sec r310; smoke alarms r313; energy efficiency chapter 11. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish bsmt. bedrooms not allowed in bsmt without emer. egress per sec r310. shall comply to ldc single family residential tree requirements in chapter 5 and 10. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manufacturer per r613.1 to be delivered to the field inspector .-cc
Valuation: $6,500,000
Client: D J Associates Inc J Available Data
Permit #: 244263
6321 Echo Trl, Louisville, KY 40299
Date: Feb 20, 2009
Permit type: Remodeling
Description: New equipment shelter for a co-locate on a existing tower. see state letter of approval and msd approval in file. lm
Valuation: $669,200
Client: Towers Inc Pmb 353 Pinnacle Available Data
Permit #: 225121
3318 Warren Ave, Louisville, KY 40215
Date: Apr 5, 2007
Permit type: Commercial Contracting
Description: 200 amp temporary pole for cingular's derby cow (cellular on wheels) unit for derby 2007
Valuation: $75,000
Client: Churchill Downs Inc Available Data
Permit #: 153750
1160 Lone Oak Ave, Louisville, KY 40219
Date: Jul 21, 2006
Permit type: Remodeling
Description: New cell tower with equipemnt shelter for cingular. see planning and design approval (4-1-06) in fil
Valuation: $600,000
Client: Properties Llc Mimerden Available Data
Permit #: 123437
8121 Lake Ave, Saint Matthews, KY 40222
Date: Jun 28, 2006
Permit type: Electrical
Description: Burn-out inspection after apartment fire
Client: Properties River City Available Data
Permit #: 120237
8121 Lake Ave, Saint Matthews, KY 40222
Date: Jun 28, 2006
Permit type: Electrical
Description: Burn-out inspection after apartment fire.
Client: Properties River City Available Data
Permit #: 120235
1160 Lone Oak Ave, Louisville, KY 40219
Date: Jun 15, 2006
Permit type: Electrical
Description: New underground 400 amp 120/240 volt single phase service to new 4 gang meter center. one 200 amp me
Valuation: $470,000
Client: Properties Llc Mimerden Available Data
Permit #: 118493
3417 Tarragon Rd, Louisville, KY 40219
Date: Jun 6, 2006
Permit type: Commercial Contracting
Description: Model home only. no c.o. until sewers are completed and tested per health dept.- lot #2 cherokee acres-one story frame with unfin. bsmt., and 450 sf att. garage. shall comply to 2002 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; bsmt. walls r 404; stairs r314; handrails r315; emer. egress sec r310;
Valuation: $7,500,000
Client: D J Associates Inc J Available Data
Permit #: 117082
201 Rock Cliff Ct, Louisville, KY 40218
Date: May 18, 2006
Permit type: Electrical
Description: Replace fuses in main 400 amp switch.
Client: Y Lot 3 B Llc C Available Data
Permit #: 115076
3318 Warren Ave, Louisville, KY 40215
Date: Apr 14, 2006
Permit type: Commercial Contracting
Description: 200 amp temporary pole for cingular's derby cow (cellular on wheels) unit
Valuation: $80,000
Client: Churchill Downs Inc Available Data
Permit #: 110728
3756 Oakdale Ave, Louisville, KY 40214
Date: Apr 11, 2006
Permit type: Commercial Contracting
Description: Installing a 10' x 16' pre-fab equipment shelter for cingular wireless within the fenced in compound approved by planing & design, docket #4-1-05, as per jack ruf. all constr. shall comply with 2002 ky. bldg. code. new antenna attached to existing tower at 105 ft. height. msd approval in file. a separate electrical permit will be obtained. original state approval dated 4-8-06, #116000-000-0. aw
Valuation: $620,000
Client: Of Louisville Ky City Available Data
Permit #: 110218
3756 Oakdale Ave, Louisville, KY 40214
Date: Apr 3, 2006
Permit type: Commercial Contracting
Description: The cell tower is located @ 3801 s 4th street, the address on this application is the closest address available. new 200 amp 120/240 volt single phase underground service from existing meter center for new cingular co-locate site.
Valuation: $260,000
Client: Of Louisville Ky City Available Data
Permit #: 109165