B&W Development Llc
Po Box 1007, Prospect, KY 40059
Contact Information
B&W Development Llc Additional Information Add Info
No additional information for B&W Development Llc yet.
Reviews Write Review
No reviews for B&W Development Llc yet.
Permits (6)
1825 Casselberry Rd, Louisville, KY 40205
Date: Aug 5, 2015
Permit type: Commercial Contracting
Description: 450 sf renovation plus 616 sf addition. this parcel is for single family use only. no other use is allowed pursuant to this permit . shall comply with 2013 krc. carbon monoxide detector required, per section r315. approvals in case file. see plans on site. it is the owners responsibility to abide by all subdivision rules in the completion of this project. the applicant is required to comply with all small city rules and regulations, if this building is located in a small city. reviewed for code compliance per 2013 krc section 106.3.1. mi
Valuation: $30,700,000
Fee: $79.00 paid to City of Louisville, Kentucky
Client: Robert James Kadner Amy Kadner Available Data
Permit #: BL951635
18513 Longview Park Ln, Louisville, KY 40245
Date: Sep 13, 2013
Permit type: Remodeling
Description: 950 sf basement finish. only single family use is allowed without a conditional use permit. no extended stay use is allowed at this address. shall comply with 2007 krc and 2009 iecc. jm
Valuation: $4,500,000
Fee: $71.00 paid to City of Louisville, Kentucky
Client: Michael Egi Takako Wang Available Data
Permit #: 13BL5050
222 E Witherspoon St, Louisville, KY 40202
Date: Jul 6, 2012
Permit type: Remodeling
Description: 900 sf tenant fit - up / interior renovation for waterfront law offices. shall comply with kbc - 2007. separate permit required for electric. occupant load under 50. building is 2- b construction and sprinklered. - hh
Valuation: $4,000,000
Client: Waterfront Park Place Llc Available Data
Permit #: 334319
3306 Trinity Rd, Louisville, KY 40206
Date: Jun 12, 2012
Permit type: Remodeling
Description: Revised plans have been submitted and approved (see eb web) 7-16-12 -cc ***400 sf renovation on first and second floor to change floor plan to accommodate for the 580 sf two story addition ( first floor breezeway, mud room and family- second fl hall and laundry) w/ 1408 sf att two story garage.shall comply w/ 2007 krc. separate permit for electrical, hvac or plumbing. shall not encroach any sideyards or easements. for single family use only.bedrooms not allowed with out egress. lvl load calcs to be given to the building inspector prior to co. ** existing headers or materials are at the owners own risk and subject to the building inspector discretion** -cc
Valuation: $10,000,000
Fee: $50.00 paid to City of Louisville, Kentucky
Client: Daniel J Tackett Stacy W Lowe Available Data
Permit #: 331660
406 N Beckley Station Rd, Louisville, KY 40245
Date: Feb 28, 2012
Permit type: Bathroom Remodeling
Description: 400 sf interior renovation on second floor of master bathroom of wood frame construction of single family dwelling. shall not encroach any easements or required yards. separate permit required for electric. shall comply with 2007 krc. - hh
Valuation: $1,000,000
Client: Christopher Lee & Anna Roszman Available Data
Permit #: 322364
6725 Regal Rd, Louisville, KY 40222
Date: Feb 8, 2008
Permit type: New Construction
Description: Lot 15 - 4350 sf two story of wood frame construction with brick veneer and stone with 2700 finished basemnet, 520 sf treated wood deck, and 814 sf attached garage. shall comply to 2007 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; bsmt. walls r 404; stairs r314; handrails r315; guards r316; emer. egress sec r310; smoke alarms r317. permanent address shall be posted and visible from street prior to occupancy. only single family use allowed without conditional use permit. shall not encroach any easements or required yards. separate permit required to finish bsmt. bedrooms not allowed in basement without emer. egress per sec r310. shall comply to ldc single family residence tree requirements per chapters 5 and 10. shall meet public works approval for sidewalks per ldc 6.2.6b if new street is installed without sidewalks. sidewalks , if previously installed, shall be maintained by builder until finish grade of building lot. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector. builder has load calcs for lvls at stairs/bedroom 3, kitchen/bedroom 2, leisure room beam, rear porch beam, front porch beam, and overhead garage door header/beam. has harrods creek fire protection district approval per division chief john d. marstiller for full build construction on 02/08/08 via e-mail on 02/08/08. - hh - sf treated wood deck. shall comply with 2007 krc including stairs r314; handrails r315; guards r316; floor joist span r502.3; girders r502.5; field treatment r324.3.1; fasteners r323.3. shall not encroach any easements or required yards. separate permit required for electric. shall comply with national electric safety code for existing overhead electric lines by no encroachment to same and shall comply to e3504.1 for clearances on buildings. - hh --- permit modified to reinstate expired permit with new expiration date of 12/06/2012. no change to approved plans. new contractor due to new owners of property. - hh
Valuation: $80,000,000
Client: Glenview Springs, Llc Available Data
Permit #: 187487