Permits (8)
101 S High St, Columbus, OH 43215
Date: Aug 30, 2013
Permit type: Remodeling
Description: 101-107 s high st revision to cbld1312025. minor exterior wall revision - add night depository.
Valuation: $30,000,000
Fee: $300.00 paid to City of Columbus, Ohio
Client: Town Square Lp Available Data
Parcel #: 010291771
Permit #: PLRE1329431
101 S High St, Columbus, OH 43215
Date: Jul 24, 2013
Permit type: New Construction
Description: 101-107 s high st revision to permit cbld1312025. shell changes at all levels.
Valuation: $30,000,000
Fee: $300.00 paid to City of Columbus, Ohio
Client: Town Square Lp Available Data
Parcel #: 010291771
Permit #: PLRE1324633
101 S High St, Columbus, OH 43215
Date: Jun 14, 2013
Permit type: Remodeling
Description: 101 s high st plan approval: final reviewed for compliance under: 2011 obc and icc a117.1-2009 work not included in this approval: fire alarm fire suppression use / occupancy group: b (tenant space) construction type: iiib (101 building) description of the work: interior tenant buildout of basement, 1st floor & mezzanine of 101 s. high st. building for heartland bank. separate permits required for mechanical, electrical, plumbing, fire alarm and fire suppression. conditions of the occupancy: none design occupant load: 25 (tenant space) maximum capacity card: not required fire suppression systems: required sprinkler system: exist modified, required nfpa13 served by fire pump in 107 bldg. hazard class: light standpipe system: existing not modified riser demand (gpm): 324gpm @ 132psi at fire pump discharge. fire alarm system: existing modified manual/supervision notes / comments / conditions of the plan approval: see sheet #2 record / history: existing 4 story, mixed a-2/b/s-2 (enclosed parking garage) bldg combined from 107 s. high (iiia construction) and 101 s. high (iiib construction); fully sprinklered and alarmed. ref permit #cbld1312035 and adjudication order #a/o2013-020.
Valuation: $22,500,000
Fee: $2,100.00 paid to City of Columbus, Ohio
Client: Town Square Limited Available Data
Parcel #: 010291771
Permit #: INTR1319387
101 S High St, Columbus, OH 43215
Date: Jun 14, 2013
Permit type: Plumbing
Fee: $150.00 paid to City of Columbus, Ohio
Permit #: MINSP1319015
101 S High St, Columbus, OH 43215
Date: Apr 19, 2013
Permit type: Remodeling
Description: 101 - 107 s high st plan approval: final reviewed for compliance under: 2011 obc and icc a117.1-2009 work not included in this approval: fire alarm/supp use / occupancy group: b (business) - 101 bldg construction type: iii-a (107 building); iii-b (101 building) description of work: combine existing, 4-story, mixed a-2/b/s-2, fully sprinkled bldg, type iii-a const (107 s. high) w/ existing, 4-story w/ bsmnt unsprinkled retail bldg of type iii-b const (101 s. high) to form one bldg. occupancy of old 101 s. high bldg changed to occ group b shell. open walls between 101 & 107 bldgs at floors 2, 3, & 4 to provide access to exits for 101 bldg. extend sprinkler & fire alarm coverage from 107 bldg into 101 bldg. conditions of the occupancy: (a) adjudication order #a/o2013-020. ohio board of building appeals met on july 1, 2013 w/ the following results: variance against item #1 of the (a/o) is given, which states section 602.1 of obc requires bldgs & structures erected or to be erected, altered or extended in height or area shall be classified in one of the five construction types defined in sections 602.2 - 602.5. variance conditions: 1.existing standpipe installed in 107 s high st bldg shall be maintained as required system & interconnected to the bldg fire suppression w/ the floor hose connections to the satisfaction of the fire official. 2. floor levels 2, 3 & 4 in 101 s high st portion of the bldg shall be protected per obc table 601 type 3a const. 3. all penetrations of floor levels 2, 3 & 4 in 101 s high st portion of structure shall be provided w/dampers per obc 716.6. 4. bldgs defined as 101 s high st & 107 s high st shall be provided w/fire suppression system installed per obc 903.3.1.1 / nfpa 13-2011 edition. 5. alt fire alarm system shall be installed in 101 and 107 bldg & maintained comprising a remote annunciator at front entrance, hvac smoke detection where required by either obc/omc, audible/visual devices throughout the entire structure; & pull stations at all identified means of egress. 6. fire protection systems shall be required to be off-premise monitored in a manner approved per obc 901.6. 7. fire protection systems & off-premise monitoring shall be considered required systems & listed as such on the certificate of occupancy by the bldg official. 8. the fire protection system & off-premise monitoring shall be maintained as required systems utilizing the ohio fire code & adopted nfpa standards. 9. variance is granted based on use/const/occupant load/ sq ft & level of activity identified on approved const docs including maint of all bldg systems & any conditions required herein. 10. cbo shall forward a copy of any c/o to fire dept having emerg response or fire prevention responsibility. variance granted noting no objection of the bldg or fire official. (b) old 101 s. high bldg approval for shell only, no occupancy. tenant finish permits req'd prior to occupancy of old 101 s. high bldg. (c) accessible routes req'd to be provided to floors 2, 3, & 4 in 101 bldg under tenant finish permits. (d) per 1001.4 fire safety & evacuation plans shall be provided for all occupancies & blds. such fire safety & evac plans shall comply w/applicable provisions of sections 401.2 & 404 of fire code & may be appr'd by div of fire to obtain a c/o. design occupant load: to be determined under future permits maximum capacity card: not required fire suppression systems: sprinkler system: exist modified, required nfpa13 served by fire pump in 107 bldg. hazard class: light standpipe system: existing not modified riser demand (gpm): 324gpm @ 132psi at fire pump discharge. alternative system: none fire alarm system: existing modified manual/supervision notes / comments / conditions of the plan approval: none record / history: 107 s. high (ref. intr1223451, intr1017087, 05110-0-02732, 05110-0-01248, iii-a construction); 101 s. high (ref. b9308335, m/iii-b).
Valuation: $30,000,000
Fee: $2,550.00 paid to City of Columbus, Ohio
Client: Town Square Lp Available Data
Parcel #: 010001470
Permit #: CBLD1312025
101 S High St, Columbus, OH 43215
Date: Apr 19, 2013
Permit type: Commercial Contracting
Description: 101 - 107 s high st removal start on floors 1-4 of an existing commercial building. work includes removal of non-load bearing walls and non-fire rated walls / ceilings only. applicant proceeds at own risk. work permitted to proceed to point of 1st inspection. reference permit application no. cbld1312025 and c.c. 4113.39. additional removal permits required for other building systems. removal start valid for 45 days from 04/19/13
Valuation: $30,000,000
Fee: $75.00 paid to City of Columbus, Ohio
Client: Town Square Lp Available Data
Parcel #: 010001470
Permit #: RMST1312028
101 S High St, Columbus, OH 43215
Date: Apr 19, 2013
Permit type: Plumbing
Permit #: MINSP1311808
101 S High St, Columbus, OH 43215
Date: Apr 19, 2013
Permit type: Plumbing
Fee: $300.00 paid to City of Columbus, Ohio
Permit #: MINSP1311806