Contractors DirectoryInformation on every contractor in United States

Jack Dyson Electric Llc

3484 Burns Pl, Makawao, HI 96768


Contact Information

Service:
Electrical
Employees:
Dyson Jack L (Responsible Managing Employee)

License:
Hawaii #CT-33518
Status:
Active
Type:
Electrical
Business Type:
Organization (Limited Liability Company)

Verified:
Status:Not verified
Insurer:
THE GREAT DIVIDE INS CO

Jack Dyson Electric Llc Additional Information Add Info

No additional information for Jack Dyson Electric Llc yet.

Reviews Write Review

No reviews for Jack Dyson Electric Llc yet.

Permits (18)

446 Cooke Rd, Kula, HI 96790

Date: May 18, 2016

Permit type: Commercial Contracting

Description: Project: donald dewitt rietow trust scope: electrical work to install receptacles in existing 4 bedroom / 2 bath dwelling built in 1985 fee summary: (4) receptacles note: refer to he76/77-2005 misc final inspection. lms 5/20/2016

Parcel #: 2230380010000

Permit #: E 20161631

51 Lokahi Pl, Haiku, HI 96708

Date: Apr 7, 2016

Permit type: Commercial Contracting

Description: Project: van dyke, felix scope: main dwelling, carport, lanai. electrical work to install a new 200a service equipment with a new feeder. install new receptacles, switches, luminaires, smoke detectors, range/oven, dryer, water heater, disposal, range hood, dishwasher, exhaust fans, ceiling fans. fee summary: underground service 1ph, 3w, 120/240v to 200a, 1 feeder not over 100a, 1732 sq. ft....one mter only allowed for this dwelling note: reviewed plan on document manager

Parcel #: 2270060020000

Permit #: E 20161149

283 Pauwela Rd, Haiku, HI 96708

Date: Mar 23, 2016

Permit type: Commercial Contracting

Description: Project: jacobs, karl scope: 2nd farm dwelling / carport / covered lanai. electrical work to install a new 100a service equipment with a new feeder. install new receptacles, switches, luminaires, smoke detectors, range/oven, dryer, water heater, disposal, range hood, dishwasher, exhaust fan, ceiling fans. fee summary: underground service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a, 1848 sq. ft....one meter only allowed for this dwelling note: reviewed plan on document manager

Parcel #: 2270081390000

Permit #: E 20160970

946 E Kuiaha Rd, Haiku, HI 96708

Date: Mar 22, 2016

Permit type: Kitchen Remodeling

Description: Project: galetto, ezequiel & lani scope: 1st farm dwelling: living room, kitchen, bath, 2 bedrooms, covered deck note: to be reviewed under 2nd farm dwelling guidelines electrical work to install a new 100a service equipment with a new feeder. install new receptacles, switches, luminaires, smoke detectors, range/oven, dryer, water heater, disposal, range hood, exhaust fans, ceiling fans. fee summary: underground service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a, 1358 sq. ft.....one meter only allowed for this dwelling note: reviewed plan on document manager

Parcel #: 2270121770000

Permit #: E 20160957

32 Puanani Pl, Kula, HI 96790

Date: Mar 15, 2016

Permit type: Decks

Description: Project: gilmore, l. donald now occupied as: dwelling & detached garage to be occupied as: main dwelling/garage/open deck scope: remove the existing roof framing & wood framed walls of the existing garage & reconstruct walls & new roof framing (for pv panels); construct open lanai & lattice privacy wall arround the spa. electrical work to install a feeder, install receptacles, switches, luminaires, dryer. fee summary: 1 feeder not over 100a, 5 receptacles, 2 switches, 4 luminaires, 1 dryer

Parcel #: 2230260140000

Permit #: E 20160871

765 Aoku Pl, Haiku, HI 96708

Date: Feb 25, 2016

Permit type: Electrical

Description: Project: sargent, epes & rebecca scope: main dwelling with carport. electrical work to install a new 200a service equipment with a new feeder. install new receptacles, switches, luminaires, smoke detectors with battery back-up, range/oven, dryer, water heater, disposal, range hood, dishwasher, exhaust fans, ceiling fans. fee summary: overhead service 1ph, 3w, 120/240v to 200a, 1 feeder not over 100a, 2240 sq. ft.....one meter only allowed for this dwelling note: reviewed plan on document manager

Parcel #: 2270100230000

Permit #: E 20160659

2841 W Lelehuna Pl, Haiku, HI 96708

Date: Jan 4, 2016

Permit type: Commercial Contracting

Description: Project: joseph d larocco scope: revamp 100a meco utility meter with a feeder on existing 3 bedroom / 1 bath dwelling built in 1981 fee summary: underground service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a

Parcel #: 2270320040000

Permit #: E 20160006

218 Oili Rd, Haiku, HI 96708

Date: Dec 7, 2015

Permit type: Commercial Contracting

Description: Project: hammer, erik scope: 2nd farm dwelling/carport - 2 bedrooms, 2 bath, cov'd lanais, carport. electrical work to install a new 100a service equipment with a new feeder. install new receptacles, switches, luminaires, smoke detector devices, range/oven, dryer, water heater, disposal, range hood, dishwasher, exhaust fans, ceiling fans. fee summary: underground service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a, 2545 sq. ft....one meter only allowed for this dwelling note: reviewed plan on document manager

Parcel #: 2270132090000

Permit #: E 20154789

1276 Nahale Pl, Lahaina, HI 96761

Date: Oct 29, 2015

Permit type: Electrical

Description: Project: michael t mccarney scope: upgrade service to 200a with a feeder on existing 6 bedroom / 4 1/2 bath dwelling built in 1990 fee summary: underground service 1ph, 3w, 120/240v to 200a, 1 feeder over 100a to 200a

Parcel #: 2450120940000

Permit #: E 20154216

5229 Lower Kula Rd, Kula, HI 96790

Date: Sep 28, 2015

Permit type: Electrical

Description: Project: eric k barto scope: upgrade service equipment from 100a to 200a on existing 5 bedroom / 4 bath dwelling built in 1935 fee summary: underground service 1ph, 3w, 120/240v to 200a, 2 feeders not over 100a

Parcel #: 2220120060000

Permit #: E 20153658

477 Kolohala Dr, Kula, HI 96790

Date: Jul 9, 2015

Permit type: Commercial Contracting

Description: Project: michael j lawton scope: revamp 200a meco utility meter on existing 1 bedroom / 1 bath dwelling built in 1987 fee summary: overhead service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a

Parcel #: 2220180060000

Permit #: E 20152281

477 Kolohala Dr, Kula, HI 96790

Date: Jul 9, 2015

Permit type: Electrical

Description: Project: michael lawton scope: revamp 200a meco utility meter on existing 4 bedroom / 2 bath dwelling built in 1979 fee summary: underground service 1ph, 3w, 120/240v to 200a, 1 feeder over 100a to 200a

Parcel #: 2220180060000

Permit #: E 20152282

43 Ulua Pl, Haiku, HI 96708

Date: Jul 6, 2015

Permit type: Bathroom Remodeling

Description: Project: diener, robert scope: new 1-story 2nd farm dwelling - 1 bathroom studio. electrical work to install a new 100a service equipment with a feeder. install new receptacles, switches, luminaires, smoke detectors, range/oven, disposal, dishwasher, exhaust fans, ceiling fans. fee summary: underground service 1ph, 3w, 120/240v to 100a, 1 feeder not over 100a, 576 sq. ft....one meter only allowed for this dwelling note: reviewed residential plan on document manager =============================================================================================== ***note: this structure will not use a new meter. to be energized from main dwelling - refer to letter from jack dyson, president of jack dyson electric llc. (letter scanned in ax). lms 9/24/2015

Parcel #: 2270360330000

Permit #: E 20152196

110 Ulua Pl, Haiku, HI 96708

Date: May 8, 2015

Permit type: Bathroom Remodeling

Description: Project: 110 ulua place (aka moretti francesco). scope: main farm dwelling - entry kitchen dining room living room master bedroom / bath 2 bedrooms 2 bathrooms deck. electrical work to install a new 200a service equipment with a new feeder. install new receptacles switches luminaires smoke detectors range/oven dryer water heater disposal range hood dishwasher exhaust fans ceiling fans. fee summary: underground service 1ph 3w 120/240v to 200a 2 feeders not over 100a 2796 sq. ft. 1 solar water heater 1 motor not over 1hp.one meter only allowed for this dwelling. note: reviewed residential plan on document manager.

Parcel #: 2270360380000

Permit #: E 20151509

100 Opalipali Pl, Kula, HI 96790

Date: Feb 18, 2015

Permit type: Commercial Contracting

Description: Project: rock bob/angie. scope: 1st farm dwl/garage/cov lanais note: to be reviewed as 2nd farm dwl dimensions: zaed approved 2nd farm dwelling (1000 sf )with 1800 sf of exterior patios and 417 sf of garage. 31 feet 7 in. by 31 feet 7 in. fee summary: underground service 1ph 3w 120/240v to 100a 1 feeder not over 100a 3217 sq. ft.one meter only allowed for this dwelling. note: e2007/0636 had expired - transfered inspection onto this permit:. e1wc - pass - 08/30/07 - chris kele - roof wiring only e1wc - pass - 04/23/08 - james (kimo) gibson - walls & ceilings.

Parcel #: 2230680080000

Permit #: E 20150471

163 Kaluanui Rd, Makawao, HI 96768

Date: Jan 15, 2015

Permit type: Bathroom Remodeling

Description: Project: rice don. scope: main farm dwelling/garage/two covered lanais - living room kitchen master bedroom/ bathroom 2 bedrooms full bathroomtwo half-bathrooms garage laundry storage. electrical work to install a new 200a service equipment with a new feeder. install new receptacles switches luminaires smoke detectors range/oven dryer water heater disposal range hood dishwasher exhaust fans and ceiling fans. fee summary: underground service 1ph 3w 120/240v to 200a 1 feeder over 100a to 200a 3035 sq. ft. 2 window a/c unit 1 motor over 1hp to 3hp.one meter only allowed for this dwelling. note: reviewed residential plan on document manager.

Parcel #: 2250040870000

Permit #: E 20150130

110 Ulua Pl, Haiku, HI 96708

Date: Jan 12, 2015

Permit type: Commercial Contracting

Description: *building permit exemption per state legislative act 203. hrs section 46-99 (as amended 2013) relating to agricultural structures. project: maliko bay farm. structure information. 1. description: ag metal storage building 2. dimensions: 24' w 36' l 12' h 3. floor area: 864 sf 4. aggregate flr area of exempted structures: 6624 5. structure composition: metal 6. exemption #: 7 24' structural span 7. electrical improvements to be installed? yes 8. plumbing improvements to be installed? no. electrical work to install a new 200a service equipment with a feeder install new receptacle & lighting branch circuits with a ceiling fan. (per electrician rogerio l abrantes service equipment to energize this structure and main farm dwelling). fee summary: underground service 1ph 3w 120/240v to 200a 1 feeder not over 100a 2 lighting branch circuits 3 receptacle branch circuits 1 ceiling fan.

Parcel #: 2270360380000

Permit #: E 20150096

44 Heaaula Pl, Haiku, HI 96708

Date: Jun 30, 2011

Permit type: Electrical

Description: Project: fernandez, marcelo (new owner)/ sandate, ronald - upgrade service equipment to 200a and electrical alteration only to install 2 feeders, relocate and/ or install plugs, switches, lights on this existing 1 bedroom/ 1 bath dwelling built in 1988. scope: underground service, 1 phase 3 wire, 120/240v to 200a, 2 feeders not over 100a, 20 receptacles, 10 switches, 20 fixtures.

Parcel #: 2280020980001

Permit #: E 20111304

Jack Dyson Electric Llc - Similar Contractors