Modular Space Corporation
1200 Swedesford Rd, Berwyn, PA 19312
Contact Information
Modular Space Corporation Additional Information Add Info
No additional information for Modular Space Corporation yet.
Reviews Write Review
No reviews for Modular Space Corporation yet.
Permits (1)
3300 Kohr Blvd, Columbus, OH 43224
Date: Jul 15, 2015
Permit type: Remodeling
Description: Status change: 7/15/2015 - status change: 7/15/2015 - per janet r / tera's request 7/15/15 revision to cbld1511059: elec service and feeders for modular classroom building 3300 kohr blvd (43224) plan approval: conditional: fire alarm and electrical designs must be submitted for separate review and approval reviewed for compliance under: 2011 obc and icc a117.1-2009 with modifications in obc 1112.0 work not included in this approval: electrical fire alarm use/occupancy group: vb construction type: e description of work: project involves installation of relocated industrialized bldg for classroom use for columbus bilingual school @ 3300 kohr blvd. approved as separate bldg on same lot (503.1.2). work includes foundation, 2 egress ramps, 1 egress stair, and utitility connexions. separate permits are required for electrical, plumbing and fire alarm. conditions of the occupancy: obc 1001.4 - fire safety and evacuation plans must be provided for all occupancies and buildings and shall comply with the applicable provisions of sections 401.2 and 404 of the fire code; evacuation plans must be approved by the division of fire. occupant load: 140 maximum cap card: not required fire suppression systems: not required sprinkler system: none standpipe system: none commodity class: not applicable alternative system: none fire alarm system: required manual conditions of the plan approval: see page #2 record / history: existing building church/daycare bldg @ 3360 & 3400 kohr blvd; relocated iunit @ 3310 kohr, group e, ref permit #iunit1423516. specific plan approval conditions: 1. obc 715.4.1 - in addition to a fire damper, corridor walls penetrated by a duct or air transfer opening must be protected by a smoke damper. 2. obc 1006.3 - emergency power must be provided for means of egress illumination at exterior egress components and landings. 3. opc 305.6 - water, soil, and waste pipes installed outside of the building or any other place subjected to freezing shall be protected from freezing by insulation or heat or both. 4. opc 410.1 - when a bottled water dispenser is specified, it must be installed or a copy of a lease or purchasing agreement must be shown to the plumbing inspector prior to final approval. conditional plan approval: per section 105.1.2, obc - a conditional approval is a conditional license to proceed with construction or material up to the point where construction or materials objected to by the agency are to be incorporated into the building. conditions of the plan approval are issued as an adjudication order denying the issuance of a license and may be appealed in accordance with section 3781.19 of the revised code. the conditions of the plan approval are as follows: 1. fire alarm plans are required to be filed for review and approval as required by obc 106.1.1.1. 2. electrical design drawings for new work are required to be filed for review and approval as required by obc 106.1.1.
Client: New Covenant Believers Available Data
Permit #: PLRE1522581