Contractors DirectoryInformation on every contractor in United States

Toscano Frank Toscano Electric

453 Tomlinson Rd, Bryn Athyn, PA 19009


Contact Information

Service:
Electrical

HIC #:
16303
Status:
Active
City:
Philadelphia
Type:
Electrical Contractor

Verified:
Status:Verify
Date:August, 2015
Source:City of Philadelphia Licensed Contractors

Toscano Frank Toscano Electric Additional Information Add Info

No additional information for Toscano Frank Toscano Electric yet.

Reviews Write Review

No reviews for Toscano Frank Toscano Electric yet.

Permits (7)

826 Vernon Rd, Philadelphia, PA 19119

Date: May 8, 2014

Permit type: Electrical

Description: Installation of a 200a service, 40 circuit panel with ground rod...in accordance with 2008 nec for a one family building

Permit #: 534830

2822 Newberry Rd, Philadelphia, PA 19154

Date: Jul 18, 2013

Permit type: Electrical

Description: To amend ap# 431511 to change from a 200a service to a 100a service-in accordance with 2008 nec for a one family building.. no other work on this permit...

Permit #: 483853

1134 Fillmore St, Philadelphia, PA 19124

Date: Jul 11, 2013

Permit type: Kitchen Remodeling

Description: Install (3)20amp circuits to kitchen area (2) gfci protected with 6 feet of sink area)per 2008 nec

Permit #: 482353

2822 Newberry Rd, Philadelphia, PA 19154

Date: Oct 12, 2012

Permit type: Bathroom Remodeling

Description: 3- 20a circuits,20-receptacles,2- 15a circuits, 7 switches, 2-fans,1 exhaust fan, 4-20a circuits-gfci, 2-kitchen, laundry room and bathroom. install 6 smoke detectors to new and existing portions. 200a service entrance equip w/grnd rod w/40 ckt panel... in accordance with 2008 nec for a one family bldg

Permit #: 431511

3601 Genesee Pl, Philadelphia, PA 19154

Date: May 8, 2012

Permit type: Bathroom Remodeling

Description: Install 2 100a mcb panels, 2 20a gfci circuits to laundry area, 2 20a gfci circuits to bathroom & replace 4 receptacles with gfci receptacles.

Permit #: 403336

2831 Newberry Rd, Philadelphia, PA 19154

Date: Dec 4, 2007

Permit type: Electrical

Description: Install (6) 20 amp circuits, (2) 15 amp circuits with total 32 outlets - 3 fan outlets with switch, (4) smoke detectors - (2) gfi outlets, (2) arc fault circuits (east dist)

Permit #: 119432

2418 80Th Ave, Philadelphia, PA 19150

Date: Dec 5, 2006

Permit type: Electrical

Description: 9 - total - #12 - 20 amp circuits 4 - total - #14 - 15 amp circuits 2 - total - #12 - 20 amp circuits 6 - smoke detectors

Permit #: 42560