Shefsky Jeffrey Brandon Electric Inc
7335 Rising Sun Ave, Philadelphia, PA 19111
Contact Information
Shefsky Jeffrey Brandon Electric Inc Additional Information Add Info
No additional information for Shefsky Jeffrey Brandon Electric Inc yet.
Reviews Write Review
No reviews for Shefsky Jeffrey Brandon Electric Inc yet.
Permits (200)
547 Fanshawe St, Philadelphia, PA 19111
Date: Nov 30, 2015
Permit type: Electrical
Description: 200a service drop, 3- gang meter socket, 2- 100a and 1-60a service entrance cables, 2- 100a 20 circuit breaker panels with main, 1- 60a, 12- circuit breaker panel with main. full ground system... in accordance with 2008 nec for a two family building
Permit #: 654576
842 Arnold St, Philadelphia, PA 19111
Date: Nov 13, 2015
Permit type: Commercial Contracting
Description: 200a servoce complete- 40-circuit panel wiht main, full ground sytem, 240v ckt, 15a arc fault with 4- outlets, switch and light, replace all switches and outlets throughout, bath gfi.. in accorance with 2008 nec for a one family building
Permit #: 651795
1233 E Colona St, Philadelphia, PA 19125
Date: May 19, 2015
Permit type: Electrical
Description: Replace 100a, 20 circuit breaker panel with main breaker, full ground rod system, refeed power to 5- lights.... in accordance with 2008 nec for a one family building
Permit #: 610770
1700 Loney St, Philadelphia, PA 19111
Date: May 5, 2015
Permit type: Commercial Contracting
Description: 200a service drop, 2- gang meter socket, 2- 100a service entrance cable, 2- 100a, 20 circuit panels w/main, ground rod system.... in accordance with 2008 nec for a two family building contractor claims no common areas.. please check
Permit #: 606854
2139 Cypress St, Philadelphia, PA 19103
Date: Jan 29, 2015
Permit type: Electrical
Description: Complete re-wire.. include arc faults as needed, 200a service complete, 40 circuit breaker panel with main, full ground rod system... in accordance with 2008 nec
Permit #: 587109
435 E Durham St, Philadelphia, PA 19119
Date: Jan 15, 2015
Permit type: Electrical
Description: Replace 200a, 40 circuit breaker panel with main, ground rod system; replace knob and tube throughout as needed, arc fault as required... all work in accordance with 2008 nec for a one family building
Permit #: 584503
4038 Ford Rd, Philadelphia, PA 19131
Date: Sep 22, 2014
Permit type: Electrical
Description: Replace 200a service drop, 2- gang meter socket, 2- 100a circuit panels w/mains, ground rod system.... in accordance with 2008 nec for a two family building (separate meter and house panel required if any common areas)
Permit #: 562985
8409 Ardleigh St, Philadelphia, PA 19118
Date: Aug 15, 2014
Permit type: Electrical
Description: Install a 200a service complete, 40- circuit panel with main and grounding rod system...in accordance with 2008 nec for a one family building
Permit #: 555802
7014 Cardin Rd, Philadelphia, PA 19128
Date: Jun 13, 2014
Permit type: Electrical
Description: 100a service complete with 20 circuit breaker panel with main, full ground rod system, install light fixture... in accordance with 2008 nec for a one family building
Permit #: 543054
855 N Taney St, Philadelphia, PA 19130
Date: Jun 13, 2014
Permit type: Electrical
Description: Replace 100a, 30- circuit panel with main; full grounding system... in accordance with 2008 nec for a one family building
Permit #: 541791
855 N Taney St, Philadelphia, PA 19130
Date: Jun 9, 2014
Permit type: Electrical
Description: Replace knob and tube in bedrooms, hall and dining room; install 11-recessed lights and wiring, replace misc outlets and switches, clean up basement wiring... in accordance with 2008 nec for a one family building
Permit #: 541367
7313 Ryers Ave, Philadelphia, PA 19111
Date: May 13, 2014
Permit type: Commercial Contracting
Description: 20a gfi protected circuit to above ground pool filter with dedicated ground switch with twist lock receptacle for pump; bonding ring around pool and pump chassis..in accordance with article 680 of the 2008 national electrical code.
Permit #: 535891
7410 Montour St, Philadelphia, PA 19111
Date: Apr 11, 2014
Permit type: Commercial Contracting
Description: 100a service complete; 30- circuit panel with main, full ground rod system. re-wire property including arc fault protection, hard-wired smoke and carbon detectors, 12- recessed lights... : repair as per nema standards for fire and water damaged wiring & equipment (one family building
Permit #: 529995
6328 Newtown Ave, Philadelphia, PA 19111
Date: Feb 26, 2014
Permit type: Electrical
Description: Replace 200a service complete- 40 circuit panel with main, full ground rod system.... in accordance with 2008 nec for a one family building
Permit #: 521085
8030 Navajo St, Philadelphia, PA 19118
Date: Oct 18, 2013
Permit type: Bathroom Remodeling
Description: 100a, 30 circuit panel with main, full ground rod system, 3 bathroom exhaust fans w/wiring, circuit for gfi, 11 lights, repl misc switches and outlets, wire & outlet for tv, fix misc exterior gfi outlets... in accordance with 2008 nec for a one family building
Permit #: 501094
8030 Navajo St, Philadelphia, PA 19118
Date: Oct 3, 2013
Permit type: Electrical
Description: Replace knob and tube throughout, 10 arc fault circuits, 16 tamper resistant outlets, 24 switches, 27 lights...in accordance with 2008 nec for a single family building
Permit #: 498368
7117 Lincoln Dr, Philadelphia, PA 19119
Date: Sep 24, 2013
Permit type: Commercial Contracting
Description: Installation of (4)recessed lights, ceiling fan, (5)outlets, 15a arc fault circuit and all associated wiring... in accordance with 2008 nec for a one family building
Permit #: 496541
2362 78Th Ave, Philadelphia, PA 19150
Date: May 17, 2013
Permit type: Kitchen Remodeling
Description: 200a service complete with 40- circuit panel with main, full ground system. re-wire kitchen: 30a cook top, 4' baseboard heat, lighting, 5- ceiling lights, microwave and refrigerator circuits...in accordance with 2008 nec for a one family building
Permit #: 471922
5419 Claridge St, Philadelphia, PA 19124
Date: Feb 7, 2011
Permit type: Electrical
Description: 100 amp service complete. 20c panel with main, complete ground system. in accordance with 2005 nec
Permit #: 139790
3104 Derry Rd, Philadelphia, PA 19154
Date: Jul 19, 2010
Permit type: Electrical
Description: 100 amp service complete with 20 circuit panel with main breaker and complete ground rod system as per 2008 nec (east dist)
Permit #: 291680