Shawn Fischbach,
2307 Mary Catherine Dr, Louisville, KY 40216
Contact Information
Shawn Fischbach, Additional Information Add Info
No additional information for Shawn Fischbach, yet.
Reviews Write Review
No reviews for Shawn Fischbach, yet.
Permits (5)
300 N 29Th St, Louisville, KY 40212
Date: Aug 16, 2010
Permit type: New Construction
Description: 72 feet of ramp plus two landings. see details of ramp design. shall maintain 3 feet setback from adjacent property lines. gp
Client: Damon L & Carol M Morgan Available Data
Permit #: 274869
16240 Eastwood Cut Off Rd, Louisville, KY 40245
Date: Jul 30, 2008
Permit type: Decks
Description: 792 sf treated wood deck. shall comply to 2007 krc including stairs r314; handrails r315; guards r316; floor joist span r502.3; girders r502.5; field treatment r324.3.1; fasteners r323.3. shall not encroach any easements or required yards. separate permit required for electric. shall comply to national electric safety code for existing overhead electric lines by no encroachment to same and shall comply to e3504.1 for clearances on buildings.has water management verbal approval per john selch on 07/30/08. - hh
Valuation: $800,000
Client: & A Davis Farm Llc J Available Data
Permit #: 205003
16240 Eastwood Cut Off Rd, Louisville, KY 40245
Date: Jul 7, 2008
Permit type: New Construction
Description: 200 sf one story frame detached accessory building with unfinished w/o basement. includes generator concrete pad. seperate permit required for electric. shall not encroach any easements or required yards. shall comply with 2007 krc, including trusses r802.10; foundation r404; footings r403; floor joist span r502.3. will deliver truss load calcs to field inspector. pva property id number 22-0034-0035-0000 taxed as agricultural use per brenda ford pva. tenant building verbal approval under pds darnell farris granted for agricultural use per (krs 100.111) ldc definitions 1.2-3. seperate permit required for mechanicals. has water mgt. initaled approval. seperate permit required for new 35 ft tall wind turbine and foundation. any retaining wall over 4 ft in height requires engineer stamped detail to be delivered to field inspector. battery room ventalation to comply with chapter 4 of the 2006 international mechanical code. has health dept stamped approval. mi
Valuation: $2,500,000
Client: & A Davis Farm Llc J Available Data
Permit #: 200639
16240 Eastwood Cut Off Rd, Louisville, KY 40245
Date: Aug 29, 2007
Permit type: New Construction
Description: Infill-1800 sf one story stone ven. with unfinshed basement, 85 sf.front porch, 150 sf screened porch, and 650 sf. att. garage. shall comply to 2002 krc including, ceiling joist span r802.4; floor joist span r502.3; rafter span r802.5; foundation r403; bsmt. walls r 404; stairs r314; handrails r315; guards r316; emer. egress sec r310; smoke alarms r317. permanent address shall be posted and visible from street prior to occupancy. separate permit will be required to finish basement. shall not encroach any easements or required yards. bedrooms not allowed in bsmt without emer. egress per sec r310. tenant building verbal approval under pds darnell farris granted for agricultural use per (krs 100.111) ldc definitions 1.2-3. has fire and health dept approvals. will deliver truss load calcs, beam load calcs and porch column load detail to field inspector. has architecy gary watrous stamp on plans. has water mgt initaled approval. pva property id number 22-0034-0035-0000 taxed as agricultural use per brenda ford pva. seperate permit required for mechanicals. cc/mi
Valuation: $30,000,000
Client: James T Jr Davis Available Data
Permit #: 170254
3411 Goose Creek Rd, Manor Creek, KY 40241
Date: Mar 17, 2006
Permit type: Additions
Description: 10x12 one story frame slab on grade sunroom addition. has vault detail & ridge chart. no retaining walls. shall comply with 2002 krc. property is on sewers and not in flood prone area. shall not encroach any easments or required yards. dmt
Valuation: $3,500,000
Client: Living Trust The Perkins Available Data
Permit #: 107240