275 Granvil Dr, Louisville, KY 40218
Date: Aug 15, 2014
Permit type: Remodeling
Description: 462sf renovation to front bedroom and kitchen/living room. this parcel is for single family use only. no other use is allowed pursuant to this permit . shall comply with 2013 krc. has lvl beam load calcs. approvals in case file. see plans on site. it is the owners responsibility to abide by all subdivision rules in the completion of this project. the applicant is required to comply with all small city rules and regulations, if this building is located in a small city. reviewed for code compliance per 2013 krc section 106.3.1. mi
Valuation: $800,000
Fee: $50.00 paid to City of Louisville, Kentucky
Client: April Cranmer Available Data
Permit #: 14BL4109
7101 Puritan Ct, Louisville, KY 40214
Date: Dec 19, 2008
Permit type: New Construction
Description: Yorktown north sec. 11 new s/f dwelling built on existing foundation two story br veneer fin bsmt with 660' garage & 280' deck. no retaining walls.***(see wrecking permit #205989)*** exsisting foundation is subject to the building inspectors discretion and at owners own risk*** shall comply to 2007 krc including, i joist r502.1.4,trusses r802.10,engineered wood products r502.8.2,; footings r403; foundation walls r 404; headers r502; stairs r311.5; handrails r311.5.6; guards r312; separate permit required to fin bmst: bedrooms not allowed without emer. egress sec r310; smoke alarms r313; energy efficiency chapter 1102. permanent address shall be posted and visible from street prior to occupancy. shall not encroach any easements or required yards. shall comply to ldc single family residential tree requirements in chapter 5 and 10. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manfacturer per r613.1 to be delivered to the field inspector .has load calcs for trusses and lvl beam: engineer seal specification to be provided to inspector on site.-cc
Valuation: $15,916,500
Client: Michael A & Jeri L Long Available Data