Contractors DirectoryInformation on every contractor in United States

Eastwood Construction Develop

7202 Beechland Beach Rd, Prospect, KY 40059


Contact Information

Phone:
(502) 551-1982
Service:
General Contractors, Carpentry, Home Builders


Eastwood Construction Develop Additional Information Add Info

No additional information for Eastwood Construction Develop yet.

Reviews Write Review

No reviews for Eastwood Construction Develop yet.

Permits (2)

7602 River Rd, Louisville, KY 40059

Date: May 6, 2008

Permit type: New Construction

Description: 2640 sf two story brick ven.detached garage on slab.(second floor for storage only not habitable space) shall comply to 2007 krc including rafter span r802.5; ceiling joist span r802.4; footings r403. shall not encroach any easements or required yards. separate permit required for electric. no commercial use allowed. will deliver the truss load calcs and lvl load calcs to the field inspector .see permit for house # 185399.,see original permit for approval from msd and transportation. planning and zoning verbal ok per david wagner.-cc

Valuation: $3,000,000

Client: Family Llc The Bell Available Data

Permit #: 185401

7602 River Rd, Louisville, KY 40059

Date: May 6, 2008

Permit type: New Construction

Description: 7602 river rd.** infill**- 2080 sf one story br. ven.on crawl.234 front porch,440 sf covered rear porch/deck, and 576 sf att. garage.( see permit for original demolish # 156515). shall comply to 2007 krc including,trusses r802.10; floor joist span r502.3;glue lam timber r502.1.5,crawl space r408, girders r502.5; footings r403; stairs r311.5; handrails r311.5.6; guards r312; emer. egress sec r310; smoke alarms r313; energy efficiency chapter 11. permanent address shall be posted and visible from street prior to occupancy. shall not encroach any easements or required yards. shall comply to ldc single family residential tree requirements in chapter 5 and 10. shall comply with hvac sizing as specified in m1401.3. a permanent energy efficiency certificate completed by the builder or registered design professional showing r-values in zone 4, shall be posted on or in the electrical distribution panel. shall provide written window installation instructions provided by the window manufacturer per r613.1 ,the column load detail on all porches, the truss load clcs and lvl load calcs.to be delivered to the field inspector .has msd,boh,fire dept ,and transportation approval.see permit #185399 for second garage. per david wagnor in planning and design verbal approval for house and garage square feet.-cc

Valuation: $17,000,000

Client: Family Llc The Bell Available Data

Permit #: 185399